![Vitec Multimedia FOCUS FS-H60 Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/vitec-multimedia/focus-fs-h60/focus-fs-h60_user-manual_1034949021.webp)
FS-H70 / FS-H60 Portable Recorder
12
1.3 rECOrd CONTrOL
It is possible to synchronize the start/stop of recording based on the following controls:
-
NOrMAL
: Start/Stop recording can be triggered from the front panel REC button or via the
web interface.
- AUTO (only for FS-H60): recording starts and stops automatically when an active signal is
detected. Recording must be however triggered after boot up.
- AUTO+ (only for FS-H60): Similar to AUTO except that unit will automatically record by itself
after boot up.
- EXTERNAL (only for FS-H70): FS-H70 receives Start and Stop record triggers from the
ancillary data embedded in the SD/HD-SDI input stream. The SDI a source must support Start/Stop
command from the ancillary data.
- TC BREAK (only for FS-H70): FS-H70 monitors embedded timecode in the SD/HD-SDI input
stream. The recording will begin when the timecode is incrementing. When timecode stops, the
recording stops.
NOTE: When in TC BREAK mode is set, before connecting FS-H70 to the camera, make sure the
camera is set to REC-RUN mode and not recording.
In EXTERNAL/TC BREAK, the front panel REC buttons overrides the EXTERNAL or TC BREAK
commands.
1.4 TIMECOdE
TIMECODE allows the user to insert a timecode reference to the video clip in order to facilitate the
editing. Several configurations are available
- OFF
-
EXT TC
(only on FS-H70): the timecode recorded comes from the RP188 timecode located
in the SD/HD-SDI input stream.
-
FrEE rUN
: the timecode runs continuously even if a recording is not happening. Timecode
between clips are not continuous.
- REC RUN (only on FS-H60): timecode runs only when a recording is happening. Timecodes
between clips are continuous.
- CLOCK SET (only on FS-H60): start timecode equals the internal time clock of the unit.
NOTE: For FREE RUN and REC RUN modes, the device stores the last TIMECODE value when
turned off. When turned on, the TIMECODE continues form this last saved value. It is possible to
reset the TIMECODE value by changing of TIMECODE mode.