5
Bolt door bar (1062) to upper bar (1059) (4.3)
and slide door seals (3021) into the outside
side bars (4059) (4.6). Cut the door seals
(3021) to length. Please ensure that for the
inside side bar the part (4098) is used on the
right in (4R) and (4099) on the left in (4L).
Connect the door fi xers (1111), (1112) &
(1113) as shown.
The door rollers can now be slid into door
runner bar (4090) (4.7). Please ensure that
the door gliders are also running on the bot-
tom track (4.5). Once the doors are correctly
in place, connect nuts and bolts into both
ends of door runner bar (4090), as door stop-
pers.
Adjust the door so that it moves freely.
5. ROOF VENT
Connect the side bars (1065) and the top bar
(1064) depending on the glass thickness. Up
to 4 mm, see (5.1). For 4 mm and over, see
(5.2).
Place the bolts to connect the bottom bar
(1066) in the prepared holes, and then slide
the glass into the tracks in side bars (1065)
(5.3).
Now connect bottom bar (1066), ensuring that
the window is totally square before tighten ing
all bolts.
Position the window in the ridge bar from one
end (5.4) and (5.5) and slide it to the required
position (5.6).
Connect the window sill (1063), with the extra
bolts in the glazing bars (4056) (5.7).
Bolt the window opener (1067) to the bottom
bar (1066) using screws (1006) (5.8).
Place the plastic cap (1019) over the end of
the window opener (5.6) and connect both
window fi xers (2016) onto the window sill
(1063) using screws (1006) (5.8).
6. GLAZING – CLEAR/FROSTED
GLASS
Please note the already mentioned
safety precautions.
Press the glazing seals (1020) onto the alumi-
nium profi les (6.3) and cut to length.
On the roof begin by positioning the glass at
the ridge and fi x in place using the glazing
spring clips (1011) (6.2). The following pane
should slide under the pane directly above it
with the glass retaining clips (1012) between
the panes (6.1). If diffi culties arise in placing
the last pane, please ensure that those above
have not slipped down.
On the sides please begin from the bottom.
If you’ve chosen polycarbonate sheets in-
stead of glass panes, please use the instruc-
tions included in the carton with the polycar-
bonate sheets.
FINISHING
If desired, it is possible to seal the green-
house at the edges using neutral silicone.
Silicone is not in cluded.
Place the warning label inside the house.
A full range of greenhouse accessories, to
help you make the most of this product, is
available from your stockist. Please inform
yourself as to the possibilities.
SAFETY NOTICE
In the event of high wind conditions, close the
door and all vents.
In the event of heavy snowfall, clear the roof
of the building or take suitable measures to
support the roof. Heat the building in winter.
COMMENTS
For the complete protection of your new
greenhouse, we advise you to include it in
your house insurance. Please take note of
possible building rules relating to the position-
ing of greenhouses.
Please stick the included greenhouse model
label onto the door bar (1062) after success-
fully assembling this product. This information
is important in the event that replacement
parts are later required.
Please keep these Assembly Instructions in
a safe place, for future reference!
Our policy is one of continuous improvement
and we reserve the right to change the speci-
fi cations without prior notice.
007.02.1012