14
Retainer Nut Removal
• The retainer nut is easily removed using a standard
6” (15 cm) screwdriver.* Turn container upside down
and insert screwdriver shaft between the lobe and
drive spline. Push the screwdriver handle counter-
clockwise to loosen nut. Once loosened, remove
by hand.
• To replace, position retainer nut on top of blade
assembly and hand tighten. Then, using the screw-
driver, tighten clockwise until it stops. If it is not tight
enough, you will notice increased container noise.
*For best results we
recommend using a
Retainer Nut Wrench
in place of a screwdriver.
To order ask for Item #1222
Blade Agitator Assembly. Use caution when handling the
blade; it is sharp. When inserting the blade assembly through
the container bottom, grip the blades with a soft cloth and align
the flat sides of the blade assembly with the flat sides of the
container. Place the retainer nut back on the inserted blade
assembly and tighten clockwise. Do not force. Do not attempt
to disassemble blade assembly.
Drive Spline. Mates with drive socket on the motor base to
turn the blade.
NOTE:
Removing and replacing your container
while the coupling is still rotating will strip the drive spline
“teeth”. (This part is NOT removable.)
Retainer Nut. Must be snug. Use the available retainer nut
wrench for best results. (Refer to the diagram below to remove
or replace.)
Never use a blade assembly with loose, damaged or knicked components.
Retainer Nut
Lobe
Drive Spline
Blade Agitator Assembly