VW801, VW802, VW803, VW804 Serial-WiFi Modem User Manual
Vitalwell Electronics (Zhuhai) Pte. Ltd. www.vital-well.com
email:
25
u
Set Operation
AT+UARTFT=<time ><CR>
+ok<CR><LF><CR><LF>
n
Parameters:
u
time: Range 100 ~10000; Unit: ms. Auto-frame trigger time
4.2.2.14. AT+UARTFL
n
Function: Set/Query UART auto-frame trigger length;
n
Format:
u
Query Operation
AT+UARTFL<CR>
+ok=<len><CR><LF><CR><LF>
u
Set Operation
AT+UARTFL=<len ><CR>
+ok<CR><LF><CR><LF>
n
Parameters:
u
len: Range 8 ~1000; Unit: Byte. Auto-frame trigger length;
4.2.2.15. AT+UARTTE
n
Function: Set/Query UART free-frame trigger time between two bytes;
n
Format:
u
Query Operation
AT+UARTTE<CR>
+ok=<mode><CR><LF><CR><LF>
u
Set Operation
AT+UARTTE=<mode><CR>
+ok<CR><LF><CR><LF>
n
Parameters:
u
mode:
²
fast: free-frame trigger time between two bytes is 10ms;
²
normal: free-frame trigger time between two bytes is 50ms;