background image

System Operation

 

The VitalWear VitalWrap System is comprised of a control unit, a tubing set 
and a thermal wrap. This VitalWrap is the part of the system that you actu-
ally apply to the body to provide cooling and compression therapy. The wrap 
can be applied to virtually any area of the body that can be treated with a 
compressive bandage. 

Setting up the system is a simple three-step process. (1) The user first fills 
the portable, leak-proof container of the control unit with ice and water, (2) 
then applies the VitalWrap around the injured area and secures it with its 
Velcro

 closure, and (3) finally, attaches the control unit to the wrap via the 

tubing set. 

Once the control unit is turned on, cooled or warmed fluid is passed through 
the tubing set from the control unit to the wrap. The fluid is then circulated 
through  the  wrap,  drawing  heat  from  or  applying  to  the  body  and  deeply 
cooling or heating the body part. The fluid is then passed back through the 
tubing set to the control unit where it is re-cooled or re-warmed and then 
re-circulated back to the wrap. 

When  using  this  system,  please  check  the  skin  where  the  wrap  is 
applied periodically. Discontinue use if continued numbness, skin 
discoloration, blisters, etc. are present. Please refer to your health 
care  professional  prior  to  applying  this  system  and/or  using  the 
system for extended periods of time.

The benefit of compression can continue even if the user chooses to discon-
nect the tubing set from either the control unit or the wrap. 

Warranty

VitalWear,  Inc.  guarantees  this  product  free  from  defects  in  material  and 
workmanship for a period of 1 year from the date of purchase except as noted 
below. This warranty extends only to the original retail purchaser.

This VitalWear product warranty does not cover damage caused by misuse or 
abuse; accident; the attachment of any unauthorized accessory; alteration to 
the product; or any other conditions whatsoever that are beyond the control 
of VitalWear. VitalWear shall not be responsible for any type of incidental, 
consequential or special damages. All implied warranties, including but not 
limited to those implied warranties of fitness and merchantability, are limited 
in total duration of 1 year from the original purchase date.

To obtain warranty service on your VitalWear VitalWrap System, either hand 
deliver or mail the unit and your dated sales receipt (as proof of purchase) 
to VitalWear, Inc. (384 Oyster Point Blvd., Suite 16, South San Francisco, 
CA 94080-6523). Be sure to include the serial number of your unit and your 
phone number on any correspondence. If you have any questions, please call 
VitalWear Inc. at 1-800-553-4081.

Upon receipt, VitalWear will repair or replace, as appropriate, your VitalWrap 
System and return it to you, postpaid. Warranty is solely through VitalWear 
Service  Center.  Service  of  this  product  by  anyone  other  than  VitalWear 
Service Center voids warranty.

This warranty provides you with specific legal rights. You may have additional 
rights, which may vary from state to state. Because of individual state regula-
tions, some of the above limitations and exclusions may not apply to you. 

4

5

control unit

thermal wrap

tubing set

Содержание VitalWrap System

Страница 1: ...VitalWrap System Users Manual...

Страница 2: ...manual completely prior to using the unit to ensure reliable and safe operation VitalWrap System Introduction 2 VitalWrap System Specifications 3 Warranty 4 System Operation 5 Notes Cautions And Warni...

Страница 3: ...04 7 191 798 VitalWrap System Introduction A significant number of Americans suffer from some type of persistent or recurrent acute pain sufficient to significantly impact their lives The VitalWear Vi...

Страница 4: ...l unit or the wrap Warranty VitalWear Inc guarantees this product free from defects in material and workmanship for a period of 1 year from the date of purchase except as noted below This warranty ext...

Страница 5: ...ts Grounding reliability can only be achieved when the equipment is connected to an equivalent receptacle marked hospital only or hospital grade When using an electrical appliance especially when chil...

Страница 6: ...lief of pain Fever reduction Control of bleeding Prevention or reduction of swelling of traumatic origin Prevention or reduction of inflammation Decrease of muscle guarding and spasm Temporary reducti...

Страница 7: ...eas of recent hemorrhage or potential hemorrhage Application over areas of known malignancy Application over areas of acute inflammation Application over areas of infection Application over areas wher...

Страница 8: ...ubing Set connector on the outside of the roll 2 Start Wrapping Place the bladder portion of the wrap around the treat ment area 3 Secure it Finish wrapping using the Velcro closure Connect the wrap t...

Страница 9: ...ect and disconnect Wrapping Other Body Parts The 6 VitalWrap included with your system can be applied to the calf knee hamstring thigh hip upper and lower back abdomen and chest Please contact VitalWe...

Страница 10: ...using the Velcro closure Connect the wrap to the Tubing Set by aligning the Orientation Dots as shown Press both but tons on the Tubing Set connector to connect and disconnect 1 2 3 1 2 3 Wrapping You...

Страница 11: ...wrapping using the Velcro closure Connect the wrap to the Tubing Set by aligning the Orientation Dots as shown Press both but tons on the Tubing Set connector to connect and disconnect 1 2 3 1 2 3 Tub...

Страница 12: ...onds c Repeat on opposite end D Wrap Procedures a Use a small blunt tool to depress left connector of wrap with dot facing up for 30 to 60 seconds b Reconnect tubing set to unit and wrap Pumping shoul...

Страница 13: ...____ ____________________________________________________________ ____________________________________________________________ ____________________________________________________________ ____________...

Страница 14: ...___________________________________ ____________________________________________________________ ____________________________________________________________ __________________________________________...

Страница 15: ...VitalWear Inc 384 Oyster Point Blvd Suite 16 South San Francisco CA 94080 1968 www vitalwear com 1 800 553 4081 in U S or 650 553 4100 Part number 00033 Rev J Put a Wrap on PainSM...