7737 User Guide
© 2021 Vital Systems, Inc.
5
www.vitalsystem.com
Pre-requisites to get motion working on 7737 with:
HiCON Integra
The 7737 and Integra combo requires these steps for proper operation:
1.
Make sure that Integra has an Extended I/O Activation.
2.
Enable J7/J8 plugs for Step/Dir operation using VSI Device Manager.
3.
Map the Drive Enable pin of 7737 on Mach4. Make sure the polarity is such that when Mach4 is
enabled, blue LED lights up on the 7737 Board.
4.
Make sure ESTOP jumper is installed or ESTOP switch is closed on the 7737.
5.
Optionally map Drive Error Signal.
DSPMCv3
The 7737 and DSPMC require these steps for proper operation:
1.
Enable J5/J6 plugs for use with the 7737 in the HiCON tab of the VSI Device Manager.
2.
Map the Drive Enable pin of 7737 on Mach4. Make sure the polarity is such that when Mach4 is
enabled, blue LED lights up on the 7737 Board.
3.
Make sure ESTOP jumper is installed or ESTOP switch is closed on the 7737.
4.
Optionally map Drive Error Signal.