![visual engineering TMC 3 Скачать руководство пользователя страница 7](http://html1.mh-extra.com/html/visual-engineering/tmc-3/tmc-3_user-manual_1034018007.webp)
TMC 3
September 2017
Visual Engineering
Video solutions. Integrated
visualengineering.co.uk
Page 7
Mesh Network Control
The Silvus StreamCaster 4200 MIMO Mesh radio forms the wireless connectivity solution for
the TMC 3. Connection to the radio’s user interface is via a web page interface. Ensure that the
controlling PC is on the same network as the Mesh radio(s) and enter the virtual IP address of a
Mesh radio on the network into the web browser’s address bar. The user interface for the Mesh
radio will be displayed as shown below.
The Mesh radio can be configured by
can selecting an option as detailed in the
various tab options.
In the open tab shown here the user may
set the Virtual IP Address of the Mesh
radio, so as to match the network it is to
be used on.
IP Addresses
All default IP addresses can be found on the label on the
base of the TMC3. This details the fixed and virtual IP
address of the Mesh radio and also the IP address of the
video encoder.
The virtual IP of the Mesh radio is entered here.
e.g.
10.206.122.101
Further support can be found
by clicking on any
?
character on
any page
.