iii
RACK MOUNTING AND
VENTILATION REQUIREMENTS:
If you are rack-mounting the Mantis base unit:
1. Always stack the rack from the bottom up to ensure a stable and safe
rack.
2. The installation of the Mantis and other units within the rack should
not reduce the airflow within the rack. The maximum recommended
ambient temperature for the Mantis is 100.4 degrees Fahrenheit (38
degrees Celsius).
3. Determine that the cumulative power requirements of the Mantis plus
the other equipment in the rack do not overload the rack supply
circuit and/or wiring.
4. When installing, consider the location of the Mantis in relation to
other devices located in an adjacent rack. Ensure that the Mantis air
intake is not drawing directly upon heated air from another unit.
Rack Depth: The minimum rack depth required to install the Mantis
is 16 inches (41 cm). If cables are used, the rack should be EMI/RFI
shielded. Ensure that the cables used meet EMI/RFI requirements and
are shielded if exposed.
Side Rails: The Mantis has side rails provided for mounting. If
different rail mounts or sliding rails are used, consult the original
manufacturer of this equipment to confirm they meet the weight and
stress requirements in order to support the Mantis chassis.