OPERATING INSTRUCTIONS
for the
AUXILIARY IDLE CONTROL MODULE
Exclusively for Ford Trucks with 7.3L DIT Diesel Engines
Powertrain Control Systems Division
Visteon Automotive Systems
Copyright ©1998
Part No. XC3F-12B639-CA
Страница 1: ...INSTRUCTIONS for the AUXILIARY IDLE CONTROL MODULE Exclusively for Ford Trucks with 7 3L DIT Diesel Engines Powertrain Control Systems Division Visteon Automotive Systems Copyright 1998 Part No XC3F...
Страница 2: ...10 14 4 1 Basic Operation 10 4 2 PTO Lower Limit Engagement 11 4 3 PTO Upper Limit Overspeed 12 4 4 PTO Linked with RPM Control 13 4 5 PTO Linked with Custom RPM Control 14 5 Programming the APCM Modu...
Страница 3: ...and Manual RPM Adjustment Arrows Each arrow key contains a preset speed allowing four 4 programmable RPM settings The arrow keys are also used to manually increase or decrease the engine speed at a fa...
Страница 4: ...L MODE Section 3 PTO RPM CONTROL LINKED Section 4 4 Custom RPM Section 4 5 REMOTE RPM CONTROL SWITCH Operation Section 3 Installation Section 6 REMOTE CHARGE PROTECT SWITCH Operation Section 2 Install...
Страница 5: ...arge Protection Press CHARGE PROTECT key A Charge Protect Light will flash Engine speed will increase to a variable RPM dependent on the battery voltage requirement Nominal system voltage will be disp...
Страница 6: ...ic Charge Protection completely you will need to re program the APCM Step 1 Section 2 3 REMOTE USAGE CHARGE PROTECTION For this module an input is available to allow remote activation and deactivation...
Страница 7: ...CONTROL key on module RPM Control Light will turn on RPM value stored in Memory 1 is displayed If desired select another RPM memory setting by pressing any ARROW key RPM value stored in the Memory se...
Страница 8: ...ic Charge Protection and return engine to normal idle Press FORD key B Press RPM CONTROL key Press POWER key Press brake pedal take vehicle out of park or release parking brake If toggled again the ve...
Страница 9: ...Step 2 Initiate Custom RPM Control The RPM Control light will turn on steady when Custom RPM Control mode is programmed RPM value associated with the Custom Input Voltage is displayed If within range...
Страница 10: ...shows the RPM value associated with the Custom input voltage If OFF is displayed the voltage input is not within 0 5 4 5V range The engine speed will be elevated within a few seconds after vehicle s...
Страница 11: ...ng diagram shows how the upper and lower PTO speed limits function when programmed Section 4 1 BASIC OPERATION OF PTO CONTROL The PTO CONTROL key works like a on off switch Press the key once to turn...
Страница 12: ...ith the ARROW keys to the desired maximum engagement speed for PTO mode 4 Save and exit programming mode by pressing the FORD key Step 2 Activate the PTO Control output Press PTO CONTROL key on the mo...
Страница 13: ...with ARROW keys to the desired maximum allowable engine speed for PTO mode 4 Save and exit programming mode by pressing the FORD key twice Step 2 Activate the PTO Control output Press PTO CONTROL key...
Страница 14: ...ey 5 Press Ford key Menu 3 shows the programmed PTO Lower Limit 6 Press Ford key Menu 4 shows the programmed PTO Upper Limit 7 Menu 5 should be set to BASE mode Press Ford key to exit NOTE Automatic R...
Страница 15: ...to exit NOTE Automatic RPM Control is not available with PTO RPM LINKED Step 2 Initiate PTO Linked with CUSTOM RPM CONTROL mode The RPM Control light will turn on steady automatically when Custom RPM...
Страница 16: ...OFF Initial Ramp Rate is set to 500 RPM second displays 88 on screen Section 5 2 APCM MAIN PROGRAMMING MODE The required programming steps for each of the module functions is covered in each respectiv...
Страница 17: ...ey to select options in each Menu To exit programming mode complete all menus OR press and hold the RPM CONTROL CHARGE PROTECT and FORD keys for 3 seconds CHARGE RPM RPM V PTO RPM V PTO PTO RPM RPM RP...
Страница 18: ...you for example a slow rate of increase for clutch durability or a fast rate for time efficiency The second menu allows the initial ramp up rate to be modified The up ramp rate is how fast the engine...
Страница 19: ...itches for all exterior applications Section 6 1 REMOTE INPUT SWITCHES Section 6 1 1 Remote Switch Installation For Remote RPM Control Remote Charge Protection use Momentary Contact push button switch...
Страница 20: ...PM value corresponds to what custom input voltage V refer to Section 9 For Remote Custom RPM Control Connect potentiometer to red VREF output black SIG RTN pink CUSTOM input The Custom Input Voltage s...
Страница 21: ...M signal on off 4 White Purple SCP Bus Twisted Pair Connects to Vehicle 5 Black Signal Return Use for Remote Custom Input 6 Black Ground Connects to Vehicle 7 Gray Remote RPM Control Input Use for Rem...
Страница 22: ...are ok replace APCM 6 Display reads EErr APCM component defective replace APCM 7 Display reads AErr APCM component defective replace APCM 8 Must press remote switch twice to activate RPM Control May h...
Страница 23: ...mum RPM for Charge Protection 1100 RPM 1998 MY Econoline 1200 RPM 1999 MY F Series 1300 RPM All previous Model Years for E F Series Maximum charge rate 2500 RPM RPM CONTROL MODE Selectable high idle o...
Страница 24: ...Part No E8EB 14A464 BZA BUS TAN ORANGE BUS PINK LIGHT BLUE KEY POWER F Series RED YELLOW E Series RED LIGHT GREEN GROUND BLACK Module Side Ford Part No F3LB 12624 ZB BUS RED BLUE BUS WHITE PURPLE KEY...
Страница 25: ...t ramps up to the desired elevated idle at a rate of 500 RPM second The down ramp rate RMP should remain at I 100 RPM sec or lower Table 9 3 2 Engine Speed Ramp Rates Ramp Rate Setting Ramp Rate LCD D...