CAUTION

 

RISK OF ELECTRIC SHOCK 

DO NOT OPEN 

CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK, 

DO NOT REMOVE COVER (OR BACK) 

NO USER-SERVICEABLE PARTS INSIDE. 

REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS  

1.  Read these instructions.  

2.  Keep these instructions.  

3.  Heed all warnings.  

4.  Follow all instructions.  

5.  Clean only with dry cloth.  

6.  Do not block any ventilation openings. Install in accordance with the 

manufacturer’s instructions.  

7.  Do  not  install  near  any  heat  sources  such  as  radiators,  heat  registers,  stoves,  or  other  apparatus 

(including amplifiers) that produce heat.  

8.  Do  not  defeat  the  safety  purpose  of  the  polarized  or  grounding-type  plug.  A  polarized  plug  has  two 

blades  with  one  wider  than  the  other.  A  grounding  type  plug  has  two  blades  and  a  third  grounding 
prong. The wide blade or the third prong is provided for your safety. If the provided plug does not fit 
into your outlet, consult an electrician for replacement of the obsolete outlet.  

9.  Protect  the  power  cord  from  being  walked  on  or  pinched  particularly  at  plugs,  convenience 

receptacles, and the point where they exit from the apparatus.  

10.  Only use attachments/accessories specified by the manufacturer.  

11.  Unplug this apparatus during lightning storms or when unused for long periods of time.  

12.  Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been 

damaged  in  any  way,  such  as  power-supply  cord  or  plug  is  damaged,  liquid  has  been  spilled  or 
objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not 
operate normally, or has been dropped.  

13.  CAUTION 

–  THESE  SERVICING  INSTRUCTIONS  ARE  FOR  USE  BY  QUALIFIED  SERVICE 

PERSONNEL  ONLY.  TO  REDUCE  THE  RISK  OF  ELECTRIC  SHOCK  DO  NOT  PERFORM  ANY 
SERVICING  OTHER  THAN  THAT  CONTAINED  IN  THE  OPERATING  INSTRUCTIONS  UNLESS 
YOU ARE QUALIFIED TO DO SO.  

14.  Use satisfy clause 2.5 of IEC60950-1/UL60950-1 or Certified/Listed Class 2 power source only.  

15.  ITE is to be connected only to PoE networks without routing to the outside plant.  

 

CE COMPLIANCE STATEMENT 

 

WARNING  

This  is  a  Class  A  product.  In  a  domestic  environment  this  product  may  cause  radio 
interference in which case the user may be required to take adequate measures.  

 

Содержание VK2-HD30IR-PM

Страница 1: ...Quick Installation Guide VK2 HD30IR PM Please read this guide thoroughly before use and keep it handy for future reference...

Страница 2: ...ment can cause severe bodily injury or equipment damage CAUTION Improper use of this equipment can cause equipment damage Note Notes contain important information about a product or procedure This app...

Страница 3: ...on or pinched particularly at plugs convenience receptacles and the point where they exit from the apparatus 10 Only use attachments accessories specified by the manufacturer 11 Unplug this apparatus...

Страница 4: ...ide angle and tracking IR for upto 300m illumination this is designed for long range internal and external use With H 264 and MJPEG encoding formats images can be viewed via the camera web page or com...

Страница 5: ...as sensors and relays enabling the system to react to alarms and activate lights or open close doors Improved Security The network camera logs all user access and lists currently connected users Also...

Страница 6: ...apping screw and plastic bushing Ceiling using the supplied M6 tapping screw and bushing 3 Wind the both thread of the pipe end with Teflon tape about 20 times for sealing Then use a silicone rubber s...

Страница 7: ...le with 10 100Mbps 3 RCA jack BLACK AUDIO INPUT 4 RCA jack GRAY AUDIO OUTPUT 5 5 pin cable YELLOW ALARM INPUT 1 WHITE ALARM INPUT 2 VIOLET ALARM INPUT 3 BROWN ALARM INPUT 4 GRAY GND 6 2 pin cable RED...

Страница 8: ...ting Alarms A1 A2 A3 A4 Alarm Input 1 2 3 4 You can use external devices to signal the camera to react on events Mechanical or electrical switches can be wired to the A1 A2 A3 A4 Alarm Input 1 2 3 4 a...

Страница 9: ...eful not to reverse the polarity when you connect the power cable If you use PoE to supply power to the camera you must use the included mains powered PoE Power over Ethernet injector included with th...

Страница 10: ...vice to the network and power up 2 Start SmartManager utility Start All programs SmartManager SmartManager The main window will display and after a short while any network devices connected to the net...

Страница 11: ...streaming video in Microsoft Internet Explorer set your browser to allow ActiveX controls 3 1 Access from a browser 1 Start a browser Internet Explorer 2 Enter the IP address or host name of the netw...

Страница 12: ...ayed when the network camera is accessed for the setup at the first time Enter your admin name and password set by the administrator NOTE The default administrator user name and password is admin If t...

Страница 13: ...eo stream on the Live View page Stream profiles are configured under Setup Basic Configuration Video Image For more information please see Basic Configuration Video Image of User s Manual The resoluti...

Страница 14: ...a pop up window to manually start or stop the event The PTZ button activates a pop up window for Pan Tilt and Zoom control The VCA button shows hides VCA rule setting and detected objects The Face Det...

Страница 15: ...n the SD local storage select it from the list and click the Playback buttons Go to the first go to the beginning of the video clip Fast backward play fast play backward of the video clip Backward pla...

Страница 16: ...layed monthly If there is a recorded data for a particular date a blue square on the date will be displayed If you select a particular date in the calendar a yellow square on the date will be displaye...

Страница 17: ...ton of the Live View page Accessing the network camera from a computer for the first time opens the Admin Password dialog box Enter your administrator or operator id and password to get into setup pag...

Страница 18: ...024x768 24bpp or higher General Performance Considerations When setting up your system it is important to consider how various settings and situations will affect performance Some factors affect the a...

Страница 19: ...Vista 210 Wharfedale Road Winnersh Triangle Wokingham Berkshire RG41 5TP Subject to change without notice Version 1 0 50304036A...