69
VK2-600PTZ User manual
5 Dome Communication (RS485 Addressing etc)
DOME COMMUNICATION SETUP
DOME ID : 001
PROTOCOL : AUTO
BAUDRATE : 9600
SAVE AND EXIT(ESC TO EXIT)
To operate on RS485 each dome camera must have a unique address (ID).
When installing multiple dome cameras using an analogue DVR, it is suggested that the dome
camera address matches input number on the DVR.
The factory default setting is 1.
Example:
Port 1 = Dome 1, Port 2 = Dome 2 … Port 16 = Dome 16. If more than 16 dome
cameras are installed using two or more multiplexers, ID of the dome camera should be ID of
MUX x No. of camera IN. (e.g. multiplexer ID= n, Camera IN= m then ID of Dome =16x(n-1)+m )
Each dome is factory defaulted to address 1. It is therefore necessary to individually address
each dome on the network.