5. EVENT SETUP
5.1 ALARM SETUP
5.1.1 ALARM INPUT (ON / OFF): Select ‘ON’ if you want to use alarm input device.
5.1.2 INPUT TYPE: Select alarm input type between ‘Normally Open’ and ‘Normally Close’
NC: NORMAL CLOSE
NO: NORMAL OPEN
5.1.3 ALARM OUTPUT:
ALARM INPUT
ALARM OUTPUT
Normally Open
Normally Open
Alarm input type is Normal Open.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Open
Normally Closed
Alarm input type is Normal Open.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Normally Closed
Normally Open
Alarm input type is Normal Close.
The device connected to alarm output is in ‘OFF ‘status
and turns ON when events occur.
Normally Closed
Normally Closed
Alarm input type is Normal Close.
The device connected to alarm output is in ‘ON ‘status
and turns OFF when events occur.
Note
: In ‘Normal Close’ mode, if an intruder cuts the cable that connects the sensor to the MiniD400, the unit will
start to record automatically. In ‘Normal Open’ mode, if an intruder cuts the cable that connects the sensor to
the MiniD400, the unit will not start to record.