background image

Getting Started - 

About Your Amplifier

 

Your 

model i34 

amplifier was designed to provide a significant value based on a high performance to price 

ratio that will exceed the sonic quality of good solid state amplifiers with its musical accuracy. 

The 

model i34 

uses 2 sets of matched pairs or one matched quad (total of 4) of E34L power output tubes and 

two ECC832 preamp tubes. The 

model i34 

is designed to work in class AB and deliver up to 35W of clean 

power. Parts are carefully chosen for the optimum sound quality and the overall circuit layout is maximized for 
sonic purity.  

Construction and Testing

 

Like every Vista Audio product, your power amplifier has been carefully crafted by skilled mechanics. To assure 
consistent performance, each 

model i34 

amplifier goes through the full battery of electrical tests, extended 

burn-in and listening evaluation before being shipped. This time-consuming perfectionist approach in the design 
and manufacturing of audio equipment is intended to provide the best in musical satisfaction with lasting value. 

Handling Vacuum Tubes

 

Many people have never had experience handling vacuum tubes. Process is very similar to handling 
incandescent light bulbs. As with light bulbs, you should not touch a vacuum tube when it is operating since 
you can burn yourself. Similarly, if a tube is dropped on a hard surface it will break. When replacing the tubes 
allow sufficient time, minimum 30 minutes, for tubes to cool down and internal capacitors to discharge. Before 
you insert a tube you should make certain the unit is disconnected from the AC outlet and that the tube has 
cooled down. Inspect the tube for cracks and physical damage. Make sure that the pins are straight. If you need 
to straighten the pins, be very careful as it may cause the glass envelope to break, causing the tube to lose the 
vacuum and fail as soon as the amplifier is powered on. Carefully align the pins with the socket and gently insert 
the tube.  

Never force a tube into a socket.

  Should you decide to buy replacement tubes from Vista Audio, 

rest assured that they were fully tested before the shipment. 

Packaging

 

Save all the packaging in a dry place. Your amplifier is a precision electronic instrument and should be properly 
packaged any time shipment is made. Because of its weight it is highly probable that the unit will be damaged 
during shipment if repackaged in a box and packing other than that designed for the unit. 

 

Preparation for Use 

Place your amplifier on a flat surface. 

 

model i34 

amplifier

 

is delivered with matched quad or two matched pairs of output tubes E34L.  The 

amplifier comes with adjusted bias and it is important to follow markings on the tube boxes and insert them 
into appropriate sockets, according to the drawing below. No biasing is required until you are ready to replace 
the output tubes with a new set. Biasing procedure is explained in the chapter about tube replacement. 

Before inserting the tubes, inspect them for cracks and physical damage. Make sure that the pins are straight. If 
you need to straighten the pins, be very careful as that may cause the glass envelope to break, causing the 
tube to lose the vacuum and fail as soon as the amplifier is powered on. Refer to the drawing below to locate 
correct location for each tube. Carefully align the pins with the socket and gently insert the tube according to the 
drawing below.  

Never force a tube into a socket.

   

 

5

Содержание i34

Страница 1: ...e step ahead a brand of ENG Vista Inc m mo od de el l i i3 34 4 I In nt te eg gr ra at te ed d T Tu ub be e A Am mp pl li if fi ie er r U Us se er r s s M Ma an nu ua al l http www vista audio com Rev 4 1 ...

Страница 2: ...r audio system Before using this amplifier please take the time to carefully read and understand the safety instructions and operating procedures Becoming familiar with all details about your amplifier will ensure safe usage and reliable operation Especially important is the section on tube layout which gives information on tube replacement The effort you invest now will be well rewarded as the ti...

Страница 3: ...onnector Always use power cord with adequate wire cross section and an electrical outlet that is grounded If you do not know whether the outlet is grounded consult your electrician or local power company 6 Power Cord Protection Power supply cords should be routed so that they are not likely to be walked on or pinched Pay particular attention to cords at plugs convenience receptacles and where they...

Страница 4: ...e 1000 2000 hrs range We strongly recommend replacing the output tubes at 12 18 months interval depending on your listening habits and signal tubes at every other power tube replacement after 24 36 months This will ensure that the amplifier always performs at its best and tube failure will not overstress other parts 3 Biasing the amplifier The model i34 amplifier uses tubes in fixed bias configura...

Страница 5: ...s cooled down Inspect the tube for cracks and physical damage Make sure that the pins are straight If you need to straighten the pins be very careful as it may cause the glass envelope to break causing the tube to lose the vacuum and fail as soon as the amplifier is powered on Carefully align the pins with the socket and gently insert the tube Never force a tube into a socket Should you decide to ...

Страница 6: ... tubes will begin to glow a soft orange light Press the power switch to 0 to turn the unit off As the heaters cool off the orange glow will slowly disappear It is normal for a vacuum tube equipment to run warm if used for prolonged periods Tubes are operating at much higher temperature and should not be touched for at least ten minutes after the unit is turned off to prevent burns Always place you...

Страница 7: ...perly connected to a high current power receptacle 4 When turning the unit on make sure the volume control is at its lowest point the volume control is at minimum when turned counterclockwise to the mechanical limit 5 The amplifier will be fully functional after only a couple of minutes However as it warms up over the first 30 minutes of operation you may notice slight improvement in the sound qua...

Страница 8: ...or ECC82 with different effects on sensitivity and sonic performance No other types of tubes can be used as they may cause a damage to the amplifier which is not covered by the warranty We do not recommend frequent changes of the tubes as the sockets are sensitive mechanical parts and are rated for relatively small number of insertions Tube rolling frequent replacement for experimenting purposes i...

Страница 9: ...ll depend on the input voltage value and even small variations of the AC line will make bias voltage drift slightly causing your readings to differ and creating perception that tubes drifted more than they actually do model i34 amplifier was designed with this in mind tubes are run well below their maximum ratings and normal variations of bias voltage will not affect their life nor performance Che...

Страница 10: ...35W Class of operation AB THD 0 3 max 1W 1kHz Bandwidth 15Hz 35kHz Input sensitivity 0 6Vrms Input impedance 50 kohm Output speaker impedance 4 and 8 ohms Tubes 2 x ECC832 4 x E34L Input Voltage 120V 60Hz 230V 50Hz available Maximum input current 2A at 120V Weight 24 lbs 10 ...

Страница 11: ...hipping instructions Either way you will need to present the original bill of sale to establish the date of purchase shipment Please do not ship your equipment without our prior authorization You are responsible for transporting your unit or arranging for its transportation You must pay the initial shipping charges but we will pay the return shipping charges if the repairs are covered by the warra...