INSTALLATION INSTRUCTIONS
Bollards and Beacons
1625 Surveyor Avenue
•
Simi Valley, CA 93063
•
(805) 527-0987
•
(800) 766-VISTA (8478)
FAX: (888) 670-VISTA (8478) • [email protected] • www.vistapro.com
12V SERIES
LUMINAIRE MOUNTING:
NOTE:
Your Vista 12 volt Bollard is provided with a ground
stake to facilitate an in-grade installation. However, for a
permanent and secure installation a concrete footing
support for the bollard post is recommended.
1. To prevent electrical shock, disconnect transformer from
electrical supply before installation or service.
2. Dig a hole approximately 3” diameter by 2” deep at
selected location.
3. Using the
1⁄2
” threaded nipple (provided), attach ground
stake to center hole in bollard base and run wire pigtail
down through hole. Insert stake with base into the ground
until bottom of base is even with grade.
4. Strip the two (2) leads from the luminaire pigtail. Using the
two (2) silicone filled safety connectors (provided),
connect the leads from the luminaire to the main supply
cable leads.
NOTE:
Luminaires are supplied with 36” of 18-2 cable pigtail
for secure connection to the main supply cable. The
wire is to be protected by routing in close proximity to the
luminaire. The wiring should be buried a maximum depth
of 6 inches (15.2 cm) in order to connect to the main
supply cable.
5. Provide power to the luminaire and check for proper
operation.
FOR USE ONLY WITH LOW VOLTAGE LANDSCAPE POWER UNITS THAT DO NOT EXCEED 25 AMPS, 15 VOLT MAXIMUM.
WARNING:
Luminaires must be installed in accordance with the National Electrical Code (NEC) and local codes.
Failure to do so will void the warranty and may result in serious injury and/or damage to the luminaire.
SAFETY WARNING:
Luminaire can become very hot depending on lamp wattage used. Lens and metal around
lamp can become hot enough to blister hands. Particular care should be taken not to locate luminaires where
small children can reach them if high wattage lamps are used.
LUMINAIRES ARE NOT TO BE INSTALLED WITHIN 10 FT. (3.05M) OF A POOL OR SPA. SECONDARY CABLE IS NOT TO
BE BURIED MORE THAN 6”. WHEN USING MULTIPLE LUMINAIRES, LOAD IS NOT TO EXCEED THE TOTAL WATTS OF
TRANSFORMER RATING. DO NOT USE EXTENSION CORDS ON POWER UNITS.
NOTE:
Always use UL recognized wire connectors for connections.
NOTE:
Save these instructions for future reference.
LUMINAIRE IS UL LISTED FOR ABOVE GROUND INSTALLATION ONLY.