www.vissonic.cn
VISSONIC ELECTRONICS LIMITED
15
7.2
Full Digital Network DSP Conference Controller CAMERA
Menu--Camera Tracking Settings
Enter the menu 'CAMERA' to set the parameters of the camera tracking.
Menu Item
Parameter
Parameter value
Description
Protocol
-
SAMSUNG,
PELCO-D,VISCA,
CUSTOM,
VCA-UDP
Select the protocol according to the
camera model, When the camera
tracking controller VIS-CATC-B is
used and the protocol needs to be set
to 'custom', the camera tracking is
processed by VIS-CATC-B without
setting the submenus' camera map
'and' start set '
Camera map (Note:
If you use the
cameras
using
SAMSUNG
or
PELCO-D protocol
need to set this
menu.Use VISCA
protocol, no need to
set this menu)
Camera select
Camera addr.
Video channel
UDP addr
001 to 016
Off,001to 255
Off,001 to 255
Off,001 to 255
Camera select--
select the camera
to setup, there totally support 16
cameras.
Camera addr.
--set the camera
address for the camera selected on
submenu
'Camera
select'.
SAMSUNG
and
PELCO-D
protocols need to set the address,
and VISCA protocol is set to off.
Video
channel
--Bind
the
camera(which set on submenu
'camera select') to the video channel
number of video switcher.(There are
no video switcher connected to the
main unit for camera tracking by
RS232, just set as Off.)
Note:
To set next camera, we just
repeat the same steps:
'Camera
Select->'Camera
addr'
->'Video channel'
The main unit will record every
times of setup for each cameras.
UDP addr--
Bind the IP of the
network camera, if you choose
VCA-UDP protocol control, you
need to set the camera IP.
Freeze Time
-
01 to 30
The camera tracking host switching
screen delay time can be set to 00
seconds to 30 seconds.
Start Set
-
01 to 16
Select the camera no.1 to 16 to start
the camera tracking setting.