D-303471 TMD-560 PG2 Installation Instructions

 

 

Figure 2. Mounting 

 

Figure 3. Temperature Probe Mounting 

1. 

Insert a flat-edged screwdriver into the slot and push 

upward to remove cover. 

2.

 Remove screw. 

3.

 Separate base from cover. 

4. 

Flex catch and remove P.C. board. 

5. 

Mark and drill 2 holes in the mounting surface. Fasten 

base with 2 countersunk screws. 

6. 

Reinsert P.C. board into base and connect the two 

wires of the probe to the terminal block. 

A.

 Terminal Jumper  

B.

 Enroll button 

C.

 LED  

D.

 Internal Temperature Sensor 

2.2. Enrollment 

Refer to the PowerMaster panel's Installer Guide and follow the procedure under the 

"02:ZONES/DEVICES"

 option of the Installer Menu. 

A general description of the procedure is provided in the following flow chart.

 

Step 1

 

Step 2 

Step 3

 

Step 4

  

 

Enter the Installer menu and select 

02:ZONES/DEVICES

 

Select "

ADD NEW  DEVICE

"  

See Note 1 

Enroll the device or enter the 
device ID

 

Select the desired detector 
number for the new flood 
detector

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Step 5

 

Step 6 

Step 7

 

Step 8

 

Configure Location parameter 

Enter PARTITIONS. 
See Note

 2 

Assign partitions to the detector 
by pressing the 

 and 

 buttons on 

the panel

 

Continue to section 2.3 

 

 

 

 

 

 

 

 

 means scroll 

 and select 

 

 

 

 

Notes:

  

[1] If the temperature detector device is already enrolled you can configure the temperature detector device parameters via the 

“Modify Devices” 

option – see Step 2. 

[2]

 

PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further 

details, see "Partitioning" in the PowerMaster Installer Guide).

 

2.3. Configuring the Temperature Device Parameters 

Enter the 

 

menu and follow the configuration instructions for the TMD-560 PG2 temperature detector device as described in 

the following table. 

Option 

Configuration Instructions 

 

 

Set the detector to detect temperatures in either Celsius or Fahrenheit. 

 

Options: 

 Celsius 

C

 (default) or 

Fahrenheit 

F

 

 

Define whether or not the control panel will report a "very hot" alert when the temperature rises above 35

C (95

F) 

for at least 10 minutes. Alert restore will occur when the temperature drops below 34

C (93

F) for the duration of 

10 minutes. 

Options: 

 Disabled

 (default) or 

Enabled

                                                 

 This option is available only through the DEFINE DEFAULTS settings, (for further details, see the PowerMaster Installer Guide). 

Z06.DEV SETTINGS 

Z06.LOCATION 

Z06.PARTITIONS 

Z06:P1

  P2    P3

 

MODIFY DEVICES 

ID No. 250-XXXX 

Z06:Temp. Sensor 

ENTR ID:XXX-XXXX 

ENROLL NOW or 

ADD NEW DEVICES 

02:ZONES/DEVICES 

VERY HOT > 35

C

 

TEMPERATURE 

C/F

 

Z06:DEV SETTINGS

 