D-303471 TMD-560 PG2 Installation Instructions
Figure 2. Mounting
Figure 3. Temperature Probe Mounting
1.
Insert a flat-edged screwdriver into the slot and push
upward to remove cover.
2.
Remove screw.
3.
Separate base from cover.
4.
Flex catch and remove P.C. board.
5.
Mark and drill 2 holes in the mounting surface. Fasten
base with 2 countersunk screws.
6.
Reinsert P.C. board into base and connect the two
wires of the probe to the terminal block.
A.
Terminal Jumper
B.
Enroll button
C.
LED
D.
Internal Temperature Sensor
2.2. Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the
"02:ZONES/DEVICES"
option of the Installer Menu.
A general description of the procedure is provided in the following flow chart.
Step 1
Step 2
Step 3
Step 4
Enter the Installer menu and select
“
02:ZONES/DEVICES
”
Select "
ADD NEW DEVICE
"
See Note 1
Enroll the device or enter the
device ID
Select the desired detector
number for the new flood
detector
Step 5
Step 6
Step 7
Step 8
Configure Location parameter
Enter PARTITIONS.
See Note
2
Assign partitions to the detector
by pressing the
,
and
buttons on
the panel
Continue to section 2.3
means scroll
and select
Notes:
[1] If the temperature detector device is already enrolled you can configure the temperature detector device parameters via the
“Modify Devices”
option – see Step 2.
[2]
PARTITIONS will appear only if PARTITIONING was previously enabled in a panel that supports the Partitioning feature (for further
details, see "Partitioning" in the PowerMaster Installer Guide).
2.3. Configuring the Temperature Device Parameters
Enter the
menu and follow the configuration instructions for the TMD-560 PG2 temperature detector device as described in
the following table.
Option
Configuration Instructions
Set the detector to detect temperatures in either Celsius or Fahrenheit.
Options:
Celsius
C
(default) or
Fahrenheit
F
.
Define whether or not the control panel will report a "very hot" alert when the temperature rises above 35
C (95
F)
for at least 10 minutes. Alert restore will occur when the temperature drops below 34
C (93
F) for the duration of
10 minutes.
Options:
Disabled
(default) or
Enabled
.
This option is available only through the DEFINE DEFAULTS settings, (for further details, see the PowerMaster Installer Guide).
Z06.DEV SETTINGS
Z06.LOCATION
Z06.PARTITIONS
Z06:P1
P2 P3
MODIFY DEVICES
ID No. 250-XXXX
Z06:Temp. Sensor
ENTR ID:XXX-XXXX
ENROLL NOW or
ADD NEW DEVICES
02:ZONES/DEVICES
VERY HOT > 35
C
TEMPERATURE
C/F
Z06:DEV SETTINGS