SPECIAL FUNCTIONS
24
D-302542
Command
Individual Partition SMS
Format
All Partitions SMS format /
Partition Disable
1
Arm AWAY
"P# AWAY <code>"
"P# AW <code>"
"AWAY <code>"
"AW <code>"
2
Arm AWAY instant
Not supported command
"AWAY INST <code>"
"AWI <code>"
3
Arm AWAY Latchkey
Not supported command
"LATCHKEY <code>"
"LK <code>"
4
Arm AWAY Latchkey instant Not supported command
"LATCHKEY INST <code>"
"LKI <code>"
5
Arm HOME
"P# HOME <code>"
"P# HM <code>"
"HOME <code>"
"HM <code>"
6
Arm HOME instant
Not supported command
"HOME INST <code>"
"HMI <code>"
7
Disarm
"P# DISARM <code>"
"P# DA <code>"
"DISARM <code>"
"DA <code>"
8
Turn light xx on
(xx = 01 – 15)
"LIGHT xx ON <code>"
"LT xx ON <code>"
"LIGHT xx ON <code>"
"LT xx ON <code>"
9
Turn light xx off
(xx = 01 – 15)
"LIGHT xx ON <code>"
"LT xx ON <code>"
"LIGHT xx ON <code>"
"LT xx ON <code>"
10
Turn PGM on
"PGM ON <code>"
"PGM ON <code>"
11
Turn PGM off
"PGM OFF <code>"
"PGM OFF <code>"
12
Define custom house identity
(see note)
"HOUSE NAME <code><house
ID>"
"HN <code><house ID>"
"HOUSE NAME <code><house
ID>"
"HN <code><house ID>"
13
Query system status
Not supported command
"STATUS <code>"
"ST <code>"
Note:
House ID includes up to 16 characters, for example JOHN'S HOUSE.
Reporting by SMS
The PowerMax Pro system can send SMS messages
to a maximum of 4 pre-selected telephone numbers.
Example of the reported SMS messages:
•
JOHN’S
HOME
**AWAY**
•
JOHN’S
HOME
**DISARM**
•
JOHN’S
HOUSE
POWERMAX: LOW BATTERY
GARAGE: LOW BATTERY
•
JOHN’S
HOUSE
STATUS MESSAGE 01
(Event list is displayed)
Note:
Status messages can be sent only to a calling
telephone whose identity number is not blocked by
the user!
Note:
The PowerMax Pro may react with a delay to
received SMS messages if a GPRS session is in
progress at the same time.
Conducting a Walk-Test
The walk-test is an indispensable operation by which
you verify that all detectors function properly, without
disturbing the neighbors with loud sirens. The test
must be performed
at least once a week
, and
should include all detectors in all zones.
Before performing walk-test, all the detectors must
be in normal state. Normal state is achieved when no
motion is made for at least 2 minutes.
Note:
During the test period, 24-hour zones will not
cause an alarm if violated, but a fire zone will
function normally.
A typical test will take place as follows:
A.
Click
. The display will read:
WALK TEST
B.
Click the
button, the display will
prompt you for your user code:
ENTER CODE
_ _ _ _