10 D-304267
PowerMaster-33 G2 Installer's Guide
PHONE WIRING IN NORTH AMERICA
A.
LINE
B.
SET
C.
RJ-31X cord
D.
8-position RJ-31X plug
E.
Brown
F.
Red
G.
Green
H.
Gray
I.
RJ-31X
jack
J.
Line from street
K.
House phones
Figure 3.3b – Phone Wiring in North America
Phone wiring in the UK:
Line terminals must be connected to pins 2 and 5 of the wall jack.
For all installations:
If DSL service is present on the phone line, you must route the phone line through a DSL filter
(refer to MESSAGE TO THE INSTALLER on page 2 for further details).
3.4 Connecting Wired Zone and Siren
(detail "B" in Figure 3.1)
If an expander module is not used, one wired zone and one low voltage siren can be connected directly to the front
panel PCB.
WIRED ZONE
*
&SIREN WIRING
A.
GND
B.
Wired Zone
C.
Siren
D.
For future use
E.
Site external siren MG electronics
MG441PDS or equivalent 6-12VDC,
150 mA Max
F.
Magnetic contact or any other contact
(not a detector)
G.
Alarm N.C.
Figure 3.4 – Wired Zone and Siren Wiring
*
Wired zones can be enrolled in any zone in the PowerMaster-30 G2 control panel from 01 to 64