DE2462U MKP-150/151/152 User Guide
5
4. ENROLLING/DELETING THE KEYPAD FROM THE P MEMORY
To enroll all the MKP-150/151/152 functions
(for complete list see P Installer Guide)
, enter the P Installer Mode from the
P keypad, and proceed as shown in the following illustration.
Note:
For PowerMax Pro, PowerMaxComplete and PowerMaxExpress control panels, please refer to the respective Installer Guide.
Note:
Refer to P
Installer Guide for details on
performing
a diagnostic test
OK
(First display is READY
or NOT READY)
READY 00:00
USER SETTINGS
WALK TEST
ENTER CODE
1. NEW INSTL CODE
2. ENROLLING
[installer code]
INSTALLER MODE
ENROL WL 2WAY KP
ENROLL WL DEVICE
ENROLLING TYPE
[KEYPAD No. 1 to 2]
(e.g. 2)
2way kp No :
2way kp No : 2
2way kp No : 2
2way kp No: 2
Enrolling a wireless
Keypad
for next
enrolling action
<OFF> TO DELETE
press back
tamper
switch
once
(
see Fig. 4)
TRANSMIT NOW
Deleting a wireless
Keypad
2way kp No: 2
ENROLL KEYFOB
Black rectangle means
that the KEYPAD No. 2
is already enrolled.
OK
NEXT
NEXT
NEXT
NEXT
OK
OK
OK
NEXT
OK
NEXT
NEXT
NEXT
ENROL WL 1WAY KP
NEXT
9. DIAGNOSTICS
NEXT
AWAY
Figure 7:
Enrolling / Deleting a MKP-150/151/152 Device from P Memory
5. DEFINING MKP-150/151/152 PARAMETERS
5.1 Installer Menu Functions
Important:
All installer settings affect only the specific keypad on
which the settings were performed.
The Installer menu enables you to perform the following functions:
SUPERVISION
The keypad transmits supervision reports periodically to the control
panel.
The options are:
15 minutes,
1
hour
and
disable
.
Note:
In FCC installations, the keypad must be set to 1 hour.
PIEZO BEEP
Here you determine whether warning beeps will sound or be muted
during exit and entry delays.
Options:
enable beeps
,
off when home
and
disable beeps
.
BACK LIGHT
The keypad and LCD back light can be activated in one of two ways:
By key press:
back light is activated for ten seconds by a long
press (2 sec) of any key.
Always on:
back light remains on continuously. (Enabled only
when the unit is connected to the AC supply.)
The options are:
OFF after 10s
and
always ON
.
JAM DETECTION
Note:
For P control panel, this feature is enabled only with
version 3.3.14 and above.
Here you determine whether jamming (interfering transmissions on
the radio channel used by the system) will be detected.
The options are:
UL 20/20
,
EN 30/60
,
class 6 (30/60),
or
disable
.
RECORD SPEECH
This mode allows you to record up to 5 custom zone names.
SERIAL NUMBER
Enables reading the system serial number for support purposes only.
5.1.1 To Set Supervision Time
Make sure the system is not in Arm mode.
The installer’s menu is accessible only to those who know the
installer’s code, which is
9
9
9
9
by factory default.
A.
Press the next button (
►
) repeatedly until the display reads:
I N S T A L L E R M O D E
B.
Press the Show / OK button (
). The display should read:
E N T E R C O D E :
_ _ _
Note:
For control panels with two installer codes, the default
INSTALLER code is 8888 and the default MASTER INSTALLER
code is 9999.
C.
Enter the installer code. The display will change to:
S U P E R V I S I O N
D.
Press <
>.
E.
Press <
►
> repeatedly to select one of the available options.
F.
Press <
> to set the selected option.
5.1.2 To Activate the Recording Mode
A.
Upon gaining access to the installer menu (see section 5.1.1 A to
C), the display will read “
SUPERVISION
”.
B.
Press <
►
>;
RECORD SPEECH
is displayed.
C.
Press <
>. The display will change to:
U S E R T E R M # 1
Note:
User Term refers to the name assigned to the recorded
zone.
Note:
It is recommended to assign custom names that are
identical to the custom names defined in the control panel.