background image

DE1164 CLIP-4N Installation Instructions 

 

CLIP

CLIP

CLIP

CLIP----4N

4N

4N

4N    

The Smallest Digital, Curtain-Type Infrared Detector  

 

Installation Instructions

 

1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION

1. INTRODUCTION    

The  CLIP-4N  is  the  smallest  and  most  elegant  curtain-pattern  PIR 
detector, designed for adjustment-free easy installation. Its function is 
based on new, patented digital signal processing.  
A  new  technology  is  used  to  include  3  different  detectors  in a single 
case,  each  programmable  for  optimized  performance  at  the  specific 
mounting  location.  This  results  in  better  catch  performance  and 
virtually no false alarms. 

The  superiority  of  this  detector  over  similar  products  is  achieved  by 
applying  an  improved  version  of  the  patented 

True  Motion 

Recognition™

  (TMR)  algorithm.  This  advanced  motion  analysis 

method allows the CLIP-4N to distinguish between the true motion of 
the human body and any other disturbances that cause false alarms.  
Detailed  coverage  patterns  and  mounting  alternatives  are  given  in 
Figures 2 through 6 below.

 

 

 

Figure 1.

 CLIP -4N General View

 

 

Figure

 

2.

 Wall-Mount Curtain

 

 

Figure 3.

 Ceiling-Mount Curtain

 

 

Figure 4.

 Overhead Curtain

 

  

Figure 5.

 Curtain / Pet Alley

 

 

Figure  6.

 CLIP-4N on Internal Doorframe

 

 

2. SPECIFICATIONS

2. SPECIFICATIONS

2. SPECIFICATIONS

2. SPECIFICATIONS    

OPTICAL

 

Number of Curtain Beams:

 2

 

Mounting Positions:

 See Figures 2 through 6. 

Mounting Height:

 Up to 3.6 m (12 ft). 

Range:

 Long, Medium and Short (jumper-selected) 

ELECTRICAL 

 

Voltage:

 10 to 16 VDC.  

Current Drain:

 About 8 mA at 12 VDC.  

Alarm  Output:

  Solid-state  relay,  N.C.,  up  to  100  ma  /  30  V,  approx.  30 

ohms internal resistance. Circuit opens upon alarm. 

Tamper Output:

 N.C., rated at 50 mA resistive / 30 VDC.  

Alarm Duration:

 2-3 seconds. 

LED: 

Walk test enabled or disabled with internal link.  

Detector: 

Dual-element low noise pyroelectric sensor.  

Microprocessor: 

8-bit, low power CMOS

.

 

ENVIRONMENTAL

  

Operating Temperature:

  -10°C to 50°C (14°F to 122°F).  

Storage Temperature:

  -20°C to 60°C (-4°F to 140°F).  

RFI Protection:

 > 20 V/m to 1000 MHz.  

PHYSICAL

  

Dimensions (H x W x D):

 70 x 28 x 25 mm (2-3/4 x 1-1/4 x 1 in.).  

Weight: 

25 g (0.9 oz).  

Color:

 White. 

PATENTS 

U.S. Patent 5,693,943 (other patents pending)

 

 

3. INSTALLATION

3. INSTALLATION

3. INSTALLATION

3. INSTALLATION    

3.1 Disassembly and Assembly

 

A.  Removing the Front Cover

 

Insert  a  small  screwdriver  into 
one  of  the  narrow  gaps  at  the 
sides of the name plate (see Fig. 
7). Lever carefully sideways, until 
the name plate arches slightly out 
and  snaps  free  (do  not  let  it  fly 
off).  Retain  the  name  plate  and 
loosen the screw within the inner 
shaft  (see  Fig.  8).  Remove  the 
cover carefully, to avoid dropping 
the screw.

 

 

Figure 7.

 Name-Plate Removal

 

B.  Installing the Front Cover

 

Carefully  fit  the  front  cover  onto 
the base, with the lens in front of 
the  sensor,  insert  the  screw  into 
its shaft and tighten it well. 
Position the name plate correctly, 
and insert one of the tabs into its 
groove.  Press  the  free  edge 
sideways  against  the  already 
seated edge, until the name plate 
arches  slightly  outward.  Then 
force the other tab into its groove, 
and  let  the name plate snap into 
place. 

 

Figure 8.

 Disassembly 

 

Отзывы: