background image

Page 1 of 2

Specifications:

Size:  

6262X, 6263X  3.84”(D) x 2.82”(W) x 4.93”(H) 

 

6267X 

 

2.80” dia x 5.80”

Weight: 

6262X, 6263X  0.8 lb.

 6267X 

 0.8 

lb.

Current draw:  0.5 Amps max. (@+12.8VDC)

Locate the unit in the desired position on a flat mounting surface, and 

using the base as a template, mark the two mounting hole locations.  

Drill the holes using a 7/32” (0.219”) drill size.  Drill a third hole, 

exterior to the base to serve as a wire access hole.  Mount the unit 

using #10 hardware.

Installation & Mounting:

Flush Mount:

Pipe Mount:

Carefully remove the LED beacon from packaging. Examine the unit for 

transit damage. If damage is found, contact the transit company or ECCO. 

Do not use damaged or broken parts.  Thread into a ½” NPT (pipe) female 

fitting.  Do not over tighten.

ECCO’s maintenance-free 6260 Series LED Beacons 

feature the latest LEDs and a Pulse8 flash pattern, 

producing a warning signal ideally suited to industrial 

applications. This cost effective unit has a wide 

operating range of 12-80V, making it the perfect light 

for use on electric vehicles.

1.   Proper installation combined with operator training in the use, care, and maintenance of emergency warning devices are essential to ensure 

the safety of you and those you are seeking to protect.

2.   Exercise caution when working with live electrical connections.

3.   This product must be properly grounded. Inadequate grounding and/or shorting of electrical connections can cause high current arcing, 

which can cause personal injury and/or severe vehicle damage, including fire. 

4.   Proper placement and installation are vital to the performance of this warning device. Install this product so that output performance of the 

system is maximized and the controls are placed within convenient reach of the operator so that s/he can operate the system without losing 

eye contact with the roadway.

5.   Do not install this product or route any wires in the deployment area of an air bag. Equipment mounted or located in an air bag deployment 

area may reduce the effectiveness of the air bag or become a projectile that could cause serious personal injury or death. Refer to the 

vehicle owner’s manual for the air bag deployment area. It is the responsibility of the user/operator to determine a suitable mounting location 

ensuring the safety of all passengers inside the vehicle particularly avoiding areas of potential head impact.

6.   It is the responsibility of the vehicle operator to ensure during use that all features of this product work correctly. In use, the vehicle operator 

should ensure the projection of the warning signal is not blocked by vehicle components (i.e., open trunks or compartment doors), people, 

vehicles or other obstructions.

7.   The use of this or any other warning device does not ensure all drivers can or will observe or react to a warning signal. Never take the right-

of-way for granted. It is your responsibility to be sure you can proceed safely before entering an intersection, driving against traffic, respond-

ing at a high rate of speed, or walking on or around traffic lanes.

8.   This equipment is intended for use by authorized personnel only. The user is responsible for understanding and obeying all laws regarding 

warning signal devices. Therefore, the user should check all applicable city, state, and federal laws and regulations. The manufacturer as-

sumes no liability for any loss resulting from the use of this warning device.

Do not install and/or operate this safety product unless you have read and understand the safety information

contained 

Failure to install or use this product according to manufacturer’s recommendations may result in property damage, serious injury, and/or death to 

those you are seeking to protect!  

!

WARNING!

Caution: 

When drilling into any vehicle surface, make sure the area 

is free from any electrical wires, fuel lines, vehicle upholstery, etc. that 

could be damaged.

            

1.  Larger wires and tight connections will provide longer service life for components.  For high current wires it is highly recommended that terminal blocks or 

soldered connections be used with shrink tubing to protect the connections.  Do not use insulation displacement connectors (e.g., 3M Scotchlock type con-

nectors). 

2.  Route wiring using grommets and sealant when passing through compartment walls.  Minimize the number of splices to reduce voltage drop.  High ambient 

temperatures (e.g., under-hood) will significantly reduce the current carrying capacity of wires, fuses, and circuit breakers. All wiring should conform to the 

minimum wire size and other recommendations of the manufacturer and be protected from moving parts and hot surfaces.  Looms, grommets, cable ties, and 

similar installation hardware should be used to anchor and protect all wiring.

3.  Fuses or circuit breakers should be located as close to the power takeoff points as possible and properly sized to protect the wiring and devices. 

4.  Particular attention should be paid to the location and method of making electrical connections and splices to protect these points from corrosion and loss of 

conductivity.  

5.  Ground termination should only be made to substantial chassis components, preferably directly to the vehicle battery.

6.  Circuit breakers are very sensitive to high temperatures and will “false trip” when mounted in hot environments or operated close to their capacity. 

Installation and Operation Instructions

Model 6262, 6263, 6267

Содержание 6260 Series

Страница 1: ...ehicle components i e open trunks or compartment doors people vehicles or other obstructions 7 The use of this or any other warning device does not ensure all drivers can or will observe or react to a warning signal Never take the right of way for granted It is your responsibility to be sure you can proceed safely before entering an intersection driving against traffic respond ing at a high rate o...

Страница 2: ...PROPER INSTALLATION OR OPERATION OR NOT BEING MAINTAINED IN ACCOR DANCE WITH THE MAINTENANCE PROCEDURES SET FORTH IN MANUFACTURER S INSTALLATION AND OPERATING INSTRUC TIONS VOIDS THIS LIMITED WARRANTY Exclusion of Other Warranties MANUFACTURER MAKES NO OTHER WARRANTIES EXPRESSED OR IMPLIED THE IMPLIED WARRANTIES FOR MERCHANT ABILITY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE OR ARISING FROM A COU...

Страница 3: ... personas vehículos u otras obstrucciones 7 El uso de este o cualquier otro dispositivo de alerta no garantiza que todos los conductores puedan observar o reaccionar a las señales de advertencia Nunca subestime el derecho de paso Es su responsabilidad asegurarse de que pueda proceder con seguridad antes de ingresar en una intersección conducir en contra del tráfico o a alta velocidad y caminar por...

Страница 4: ...timiento Reduzca al mínimo la cantidad de separaciones para disminuir la caída de tensión La temperatura ambiente elevada por ej debajo del capó reduce bastante la capacidad de traslado de la corriente de los cables fusibles y disyuntores Todo el cableado debe cumplir con el tamaño de cable mínimo y con otras sugerencias del fabricante y estar protegido contra piezas móviles y superficies caliente...

Страница 5: ...TÍA EXPRESA O IMPLÍCITA MEDIANTE LA PRESENTE SE EXCLUYEN LAS GARANTÍAS IMPLÍCITAS DE COMERCIABILIDAD O APTITUD PARA UN PROPÓSITO EN PARTICULAR QUE NO SE APLICARÁN AL PRODUCTO EL ÚNICO Y EXCLUSIVO REMEDIO DEL COMPRADOR CON RESPECTO AL CONTRATO DERECHOS POR DAÑOS O CUALQUIER OTRA TEORÍA CONTRA EL FABRICANTE RELACIONADA CON EL PRODUCTO Y SU USO SERÁ LA REPARACIÓN O EL REEMPLAZO DEL PRODUCTO SEGÚN SE ...

Страница 6: ... contrôles soient à portée de main du conducteur pour lui permettre d utiliser le système sans quitter des yeux la zone de travail 5 Ni l installation de ce produit ni le passage des câbles ne doivent entraver le déploiement d un coussin gonflable L équipement monté ou localisé dans la zone de déploiement d un coussin gonflable peut réduire l efficacité du coussin gonflable ou se transformer en pr...

Страница 7: ...de la balise à DEL L unité est conçue pour les systèmes électriques de 12 à 80 VCC valeurs extrêmes de 9 à 86 VCC Le câblage de tous les systèmes est Fil rouge positif Fil noir négatif Tous les câblages doivent être d un minimum de 18 AWG Un fusible 3 ampères est requis sur la ligne positive voir figure 1 Il est possible d employer un interrupteur pour contrôler la fonction d allumage et d arrêt d...

Страница 8: ...E AUTRE GARANTIE EXPRESSE OU TACITE LES GARANTIES IMPLICITES DE QUALITÉ MARCHANDE OU D APTITUDE À UN USAGE PARTICULIER SONT EXCLUES ET NE S APPLIQUERONT PAS AU PRODUIT LE SEUL ET UNIQUE RECOURS DE L ACHETEUR CONTRE LE FABRICANT CONCERNANT LE PRODUIT ET SON UTILISATION QUEL QUE SOIT LE FONDEMENT DE RESPONSABILITÉ INVOQUÉ RESPONSABILITÉ CONTRACTUELLE DÉLICTUELLE OU AUTRE SERA LE REMPLACEMENT OU LA R...

Отзывы: