Vislink PLTX Скачать руководство пользователя страница 6

 

PLTX Digital Power Amplifier User Manual 

 

General Information 

 

 

Issue No: 01 

 

Page: 2 

 
Ref: PLTX-ASUM-7xxx 

 

Copyright © 2017 IMT Ltd, trading as Vislink 

To be safe: 

a.

 

Operators should not stand or walk in front of any antenna, nor should they 
allow anyone else to do so. 

b.

 

Operators should not operate any RF transmitter or power amplifier with any of 
its covers removed, nor should they allow anyone else to do so. 

Worked examples: 

Antenna 

Transmitter Power 

Type 

Gain (dBi) 

Gain Ratio 

2W 

4W 

10W 

30W 

OMNI 

2.5 

1.5 

2.5 

HELIX 

20 

100 

5.6 

15.5 

PARABOLIC DISH 

35 

3,162 

22.5 

32 

50 

87 

 

 

 

MINIMUM SAFE DISTANCE (METRES)

 

 

 

The RF Radiation Power Density limit figure recommended by Vislink is based upon 
guideline levels published in: 

a.

 

IEEE standard C95.1 1999 - IEEE Standard for Safety Levels with respect to 
Human Exposure to Radio Frequency Electromagnetic Fields, 3kHz to 300GHz. 

b.

 

Guidelines for Limiting Exposure to Time-varying Electric, Magnetic & 
Electromagnetic Fields (up to 300GHz) published in 1998 by the Secretariat of the 
International Commission on Non-Ionising Radiation Protection (ICNIRP). 

Both documents define guideline RF power density limits for "Controlled" and 
"Uncontrolled" environments. An uncontrolled environment is defined as one in which the 
person subjected to the RF radiation may be unaware of and has no control over the 
radiation energy received. The uncontrolled environment conditions can arise, even in the 
best-regulated operations and for this reason, the limits defined for the uncontrolled 
environment are assumed for the Vislink recommended limit. 

Documents a. and b. also show the RF power density guidelines to be frequency 
dependent. The two documents present different power density/frequency characteristics. 
To avoid complexity and areas of uncertainty, Vislink recommend the use of a single power 
density limit across the frequency range of 100 kHz to 300GHz. The 1W/m² power density 
limit we recommend satisfies the most stringent of the guidelines published to date. 

NOTE: The IICNIRP document are free to download from the internet 

(

www.icnirp.de/emfgdl

 - PDF file). The IEEE standard is available on loan from Essex 

County Library on payment of a search fee. 

Содержание PLTX

Страница 1: ... UK Telephone 44 0 1442 431300 Facsimile 44 0 1494 775356 Email sales vislink com Website www vislink com Company Registered in England Wales no 10523708 VAT registration no GB 260 012 169 Registered Office Waterside House Earls Colne Business Park Colchester Essex CO6 2NS UK ...

Страница 2: ...l Trademark content from external companies from their websites trademark pages etc NOTE Notes show to convey additional information CAUTION Cautions show where potential equipment damage could occur WARNING Warnings show where there is potential for personal danger or risk of death Read all warnings and understand them before carrying out work on any equipment This includes peripherals and any re...

Страница 3: ...Issue No 01 Page iii Ref PLTX ASUM 7xxx Copyright 2017 IMT Ltd trading as Vislink Version Date Modification Updated By 01 24 05 2017 First release of document ...

Страница 4: ...nd Control Functions 7 4 1 Control Panel Layout 7 4 2 Front Panel Layout 8 5 Connector and Pin Outs 9 5 1 RF Output 9 5 2 DC Input 9 5 3 SDI ASI Input 9 5 4 HDMI 9 5 5 Audio Connectors 9 5 6 L1700 Optional Lemo to ASI SDI Cable 9 5 7 Fan Power 9 6 Installation Requirements 11 6 1 Handling Precautions 11 6 2 Installation 11 Figure 4 1 Front Panel Layout 7 Figure 4 2 Front Panel Layout 8 Table 2 1 P...

Страница 5: ...your local authority before disposing of these components CAUTION Tantalum Capacitors When subjected to reverse or excess forward voltage ripple current or temperature these components may rupture and could potentially cause personal injury CAUTION This system contains MOS devices Ensure you use adequate Electro Static Discharge ESD precautions to prevent accidental damage The safe working distanc...

Страница 6: ... by the Secretariat of the International Commission on Non Ionising Radiation Protection ICNIRP Both documents define guideline RF power density limits for Controlled and Uncontrolled environments An uncontrolled environment is defined as one in which the person subjected to the RF radiation may be unaware of and has no control over the radiation energy received The uncontrolled environment condit...

Страница 7: ...z and a nominal output power of 5W 10W and 20W The amplifiers feature GaN device technology and RF Pre Distortion correction techniques2 providing excellent linearity suitable for COFDM signals The unit can derive power using portable battery packs ranging from 12VDC to 28VDC3 A built in voltmeter is included to allow accurate monitoring of battery condition The RF Power output level is AGC contro...

Страница 8: ...PLTX Digital Power Amplifier User Manual Introduction Issue No 01 Page 4 Ref PLTX ASUM 7xxx Copyright 2017 IMT Ltd trading as Vislink This page is intentionally unused ...

Страница 9: ...ency range Gain vs Temperature 1 dB over temperature range Third Order Intercept 62 dBm Input VSWR 1 4 1 RF Input Connector N Type RF Output Connector N Type Power Connector 2 pin DC power connector 12 28VDC Or 20 to 30VDC with 20W Variant Neutrik Speakon NL2FX RS Part 340 0958 Monitoring LEDs DC present RF present Load fault Over temperature Power Requirement 10 to 30V DC at 150W typical Weight 2...

Страница 10: ...PLTX Digital Power Amplifier User Manual Specifications Issue No 01 Page 6 Ref PLTX ASUM 7xxx Copyright 2017 IMT Ltd trading as Vislink This page is intentionally unused ...

Страница 11: ...Panel Layout Number ID Item Description Notes 1 RF output control Rotary dial to control RF output 2 Power LED DC input power present Check load is 50Ω VSWR LED Indicates fault on RF output Issue present if LED is illuminated RF Out LED Output RF present Output present if LED is illuminated Over temp LED LED illuminates if PA temperature exceeds 60 C Check fan operation 3 Voltage display Voltage o...

Страница 12: ...yright 2017 IMT Ltd trading as Vislink Figure 4 2 Front Panel Layout Number ID Item Description 1 RF output 50Ω N type connector 2 DC input 2 pin DC power connector 12 28V 3 HDMI Connector Female v1 4 connector 4 SDI in 75Ω BNC 5 ASI in 6 Audio input 1 L 3 pin XLR 7 Audio input 2 R Table 4 2 Front Panel Description ...

Страница 13: ...tor information under part number CL120755 Connector Type BNC connector 75Ω Connector Type HDMI Female v1 4 Connector Type 2x 3 pin XLR to 5 pin Lemo CL120743 3 NOTE Please request audio connection information under part number CL120743 Connector Type 7 pin Lemo to 75Ω BNC connector NOTE Please request the optional L1700 LEMO to ASI SDI cable under part number PLTX ASSY 2001 The fan derives power ...

Страница 14: ...PLTX Digital Power Amplifier User Manual Connector and Pin Outs Issue No 01 Page 10 Ref PLTX ASUM 7xxx Copyright 2017 IMT Ltd trading as Vislink This page is intentionally unused ...

Страница 15: ...iers and never look into the open end of a waveguide or cable where RF power may be present WARNING Wipe off any water or fluids immediately WARNING Do not open or modify the assembly 1 Refer to Section 6 1 above regarding handling precautions 2 Secure the unit using the mounting holes in the interface plate at the base of the unit NOTE Orientation of the unit is non specific for operation CAUTION...

Страница 16: ...PLTX Digital Power Amplifier User Manual Installation Requirements Issue No 01 Page 12 Ref PLTX ASUM 7xxx Copyright 2017 IMT Ltd trading as Vislink This page is intentionally unused ...

Отзывы: