Template Operators Manual
Specifications
Issue No: 1
Page: 12
Ref: DVE6-ASUM-70xx
Copyright © 2019 IMT and Vislink are Vislink Technologies Inc. companies
3.4.
Remote Control / Monitoring / HPA Control
USB
For field up-grades
Remote Control (Ethernet)
10/100Mbits/s Browser / SNMP
IP Address (factory default)
192.168.0.90
Netmask
255.255.255.0
MAC address
00.1D.65.xx.xx.xx
(x is generated from unique electronic serial
number)
HPA Control
RS485 in HPA native protocol.
Monitoring Status
Ground free contacts – Open = FAIL (H/W
configurable.)
3.5.
Video
Feature
Description
Video Formats
480i/29.97
576i/25
720p/50, 59.94, 60
1080i/50, 59.94, 60
1080p/23.98, 24, 25, 29.97, 30, 50, 59.94, 60
2160p/23.98, 24, 25, 29.97, 30, 50, 59.94, 60
Video Encoder Profiles
H.265 HEVC Main, Main-10:
- H.265 HEVC 8/10 Bit to 4K 60p
H.264 AVC Main, High, Baseline up to Level 5.2:
- H.264 AVC High 10/4:2:2
- H.264 AVC 4:2:0/4:2:2
- 8/10 Bit to HD 60p
4K Native and UHD (1 Service)
HD (Up to 4 Services)
SD (Up to 4 Services):
- 4.2.0 Main
- 4.2.2 Main
Encoding
HEVC (H.265) up to four channels
AVC (H.264)
MPEG-2 (H.262)
HDR
PQ or HLG standards supported.
Closed Captions
Carried as per CC708 standard
Ancillary User Data
Used to pass data using the SMPTE 2038
standard. Invisidot data or user defined for
other types of ANC data e.g. VITC