IMPORTANT: Controllers may only allow to configure signed values. In order to set values in the range 128
… 255 the value sent in the application shall be the desired value minus 256. For example: to set a
parameter to 200? it may be needed to set a value of 200 minus 256 = minus 56. In case of two byte value
the same logic applies: Values greater than 32768 may needed to be given as negative values too.
Siren Strobe Mode (Parameter Number 0, Parameter Size 1) defines the reaction of the siren
Value
Description
0
Strobe and Siren (Default)
1
Siren only
2
Strobe only
Alarm auto stop (Parameter Number 1, Parameter Size 1) defines the auto time out of the alarm indication
Value
Description
1
60 seconds
2
120 seconds
3
no automated off
0
30 seconds (Default)
Command Classes
Supported Command Classes
Battery (version 1)
Basic (version 1)
Binary Switch (version 1)
Version (version 1)
Configuration (version 1)
Manufacturer Specific (version 1)