Behavior within the Z-Wave network

I

 On factory default the device does not belong to any Z-Wave network. The device needs to join an 

existing wireless network to communicate with the devices of this network. This process is called Inclusion

Devices can also leave a network. This process is called Exclusion. Both processes are initiated by the 

primary controller of the Z-Wave network. This controller will be turned into exclusion respective inclusion 

mode. Please refer to your primary controllers manual on how to turn your controller into inclusion or 

exclusion mode. Only if the primary controller is in inclusion or exclusion mode, this device can join or leave 

the network. Leaving the network - i.e. being excluded - sets the device back to factory default.

If the device already belongs to a network, follow the exclusion process before including it in your network. 

Otherwise inclusion of this device will fail. If the controller being included was a primary controller, it has to 

be reset first.

Push the tampering switch for at least one seconds and release it.

Operating the device

Normal operation, the LED light will not be on.

Self-Protection Mode: After put back the bracket over 5 seconds, ZM1601 will enter Self-Protection Mode. If 

the back cover is opened will trigger the Self-Protection Mode. The alarm time is default 30 seconds.

User’s controller should support Z-wave FLiRS technology.

Alarm Mode (It is the status of alarm triggered): It is based on the user’s configuration setting of LED flash 

ON/OFF and Siren ON/OFF. Note: for Default setting-Siren/Strobe Mode-Parameter will be All enable; 

Alarm Auto Stop Time-Parameter will be 30 sec.

For safety reason, replace new battery whenever ZM1601 is triggered.

Depending on the configuration settings the device will signal alarm when receiving a wireless alarm signal.

Node Information Frame

NI

 The Node Information Frame is the business card of a Z-Wave device. It contains information 

about the device type and the technical capabilities. The inclusion and exclusion of the device is confirmed 

by sending out a Node Information Frame. Beside this it may be needed for certain network operations to 

send out a Node Information Frame.

Push the tampering switch for at least one seconds and release it.

Configuration Parameters

Z-Wave products are supposed to work out of the box after inclusion, however certain configuration can 

adapt the function better to user needs or unlock further enhanced features.

(c) 2012 Z-Wave Europe GmbH, Goldbachstr. 13, 09337 Hohenstein-Ernstthal, Germany, All rights reserved, www.zwaveeurope.com - pp 3 

Содержание ZM1601

Страница 1: ...an act as a repeater for other nodes meshed network in case the receiver is not in direct wireless range of the transmitter Z Wave differentiates between Controllers and Slaves Slaves are either sensors S transmitting metered or measured data or actuators A capable to execute an action Controllers are either static mains powered controllers C also referred to as gateways or mobile battery operated...

Страница 2: ...lding will know immediately that an alarm has occurred The device can be configured to either use the strobe flash or the acoustic siren or both A tamper switch protects the device from removal or manipulation if used in security applications The device is battery powered by 4 AA standard batteries Batteries The unit is operated by batteries Use only batteries of correct type Never mix old and new...

Страница 3: ...conds ZM1601 will enter Self Protection Mode If the back cover is opened will trigger the Self Protection Mode The alarm time is default 30 seconds User s controller should support Z wave FLiRS technology Alarm Mode It is the status of alarm triggered It is based on the user s configuration setting of LED flash ON OFF and Siren ON OFF Note for Default setting Siren Strobe Mode Parameter will be Al...

Страница 4: ...umber 0 Parameter Size 1 defines the reaction of the siren Value Description 0 Strobe and Siren Default 1 Siren only 2 Strobe only Alarm auto stop Parameter Number 1 Parameter Size 1 defines the auto time out of the alarm indication Value Description 1 60 seconds 2 120 seconds 3 no automated off 0 30 seconds Default Command Classes Supported Command Classes Battery version 1 Basic version 1 Binary...

Страница 5: ...e process of removing Z Wave devices from the network Association is a control relationship between a controlling device and a controlled device Wakeup Notification is a special wireless message issued by a Z Wave device to annonces that is is able to communicate Node Information Frame is a special wireless message issued by a Z_Wave device to announce its capabilities and functions Disposal Guide...