Introduction
Thanks for choosing the Vision’s wireless door/window sensor of the home security device. This
sensor is a Z-Wave™ enabled device (interoperable, two-way RF mesh networking technology)
and is fully compatible with any Z-Wave™ enabled network and it’s security framework. Every
mains powered Z-Wave enabled device acts as a signal repeater and multiple devices result in
more possible transmission routes which helps eliminate “RF dead-sports”
Z-Wave™ enabled devices displaying the Z-Wave™ logo can also be used with it regardless of
the manufacturer, and ours can also be used in other manufacturer’s Z-Wave™ enabled
networks. This sensor monitors door/window and send Z-Wave™ signal when door or window
is opened and closed. When the device is secure included into Z-Wave network, above
communication will be encrypted.
Product Description and Specification
*** For indoor use only***
Specification:
Package Content:
Protocol: Z-Wave™ (ZM5202)
Frequency Range:
865.22MHz (ZD2102IN-5)
868.10MHz (ZD2102MY-5)
868.42MHz (ZD2102EU-5)
869.00MHz (ZD2102RU-5)
908.42MHz (ZD2102US-5)
916.00MHz (ZD2102IL-5)
919.80MHz (ZD2102HK-5)
920.00~923.00MHz (ZD2102KR-5)
921.42MHz (ZD2102BR-5)
922.00MHz~926.00MHz (ZD2102JP-5)
Operating Range: Up to 100 feet line of sight
Operating Temp.: -15°C~ 60°C (5°F ~140°F)
Battery: Panasonic CR123A * 1PC
1pc
1pc
1pc
2pcs
1pc
4pcs
1pc
ZD 2012-5 sensor
Bracket for Contact Magnet
Magnet
Adhesive tape for Magnet /
sensor
CR123A Lithium Battery
Screws for bracket/ sensor
Installation & Operation manual
Z-Wave Command Classes:
COMMAND_CLASS_ASSOCIATION_GRP_INFO
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_BATTERY
COMMAND_CLASS_CONFIGURATION
COMMAND_CLASS_DEVICE_RESET_LOCALLY
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_NOTIFICATION_V4 (Mapping COMMAND_CLASS_BASIC)
COMMAND_CLASS_POWERLEVEL
COMMAND_CALSS_SECURITY
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
Notification V4 Type
SWITCH TYPE
STATUS
Notification
Type
Reed Switch
External Switch (When Enable)
0x06
Tamper Switch
0x07
Event
Reed Switch
External Switch (When Enable)
Close: 0x17, Open: 0x16
Tamper Switch
Close:0x00; Open:0x03
V1 Alarm:
Switch Type
Status
Alarm Type
Reed Switch &
External Switch (When Enable)
0x06
Tamper Switch
0x07
Alarm Level
Close: 0x00; Open 0xFF
Configuration - External Switch
Parameter Number: 0x01
Size: 1
VALUE
ENABLE
0xFF
DISABLE
(Default)
0x00
Installation
Notice: If you are installing the entire Z-Wave™ system for the first time, please refer to
the installation guide of Z-Wave™ Interface Controller before installing ZD2102.
1. Unscrew the screw fastening the rear cover and slide the rear cover down.
2. Using the screws or adhesive tape to affix the rear cover on the frame along the
opening edge of door / window.
3. Insert a CR123A battery into the battery compartment, LED will start to flash slowly
and ZD2102 will go to sleep if user didn’t press the tamper switch within 10 seconds or
ZD2102 will send the NIF.
-1-
-2-