TECHNICAL INFORMATION
APPLIANCE INFORMATION
This appliance should be used with Natural Gas (G20) only.
Model:
V1/400/A
Gas Type
G20 natural gas
Maximum Gross Input
6.85kW (23,400 Btu/h)
Minimum Gross Input
3.8kW (13,000 Btu/h)
Inlet Pressure
20mbar ±1.5mbar
Gas Connection
8mm pipe
Ignition
Piezo Electric
Burner Injector
Cat 82—074
Pilot Type
Seagas P432D
NOx Classification
5
EFFICIENCY
There are no efficiency requirements appropriate for this type of appliance as it is intended for
decorative use. For SAP purposes the efficiency should be calculated as 20% for use in the
Space Heating Requirements calculation.
VENTILATION REQUIREMENTS
In the UK, purpose made ventilation is not normally required for this appliance except in new
build houses. However, if spillage is detected during commissioning of the appliance, this may
mean there is insufficient ventilation. Additional ventilation may then be required. Please refer to
any national ventilation requirements in this instance. In the ROI, it will be necessary to refer to
I.S. 816 issued by the National Standards Authority of Ireland.
Any air vent must not be restricted.
TECHNICAL INFORMATION
3