APPLIANCE INSTALLATION
FIRE FRONT
This appliance can be used with several different Vision Fires frets.
Any fret to be used must conform to the following dimensions (Fig. 13).
LIGHTING THE APPLIANCE
Open the gas isolation valve.
Push the control knob and turn fully anti clockwise to the position marked ‘P’ for Pilot. Hold the
control knob here until the pilot lights. Hold for a further 10 seconds to allow a stable flame.
Release the control knob and turn anti clockwise to the ‘HI’ position to ignite the main burner.
Turn the control knob clockwise to the ‘LO’ position to switch the fire to its minimum heat setting.
Push the control knob and turn clockwise to the ‘P’ position to extinguish the main burner while
leaving the pilot flame alight.
Push the control knob and turn fully clockwise to the ‘O’ position to extinguish the pilot flame. The
appliance is now turned off.
10
Fig. 13
MINIMUM OPEN AREA OF
FRET = 11,000mm²
MINIMUM OPEN AREA OF
ASH PAN COVER = 3,300mm²
MAX
HEIGHT
220MM
MINIMUM OPEN TOTAL OPEN AREA OF FRET
& ASH PAN COVER COMBINED = 16,000mm²