Trimline 38 FS

Installation instruction

12

6  GAS-TECHNICAL SPECIFICATIONS

Type of indication(s)

(1070/1071/1072/1073)

Unit type

C11, C31, C91 

Concentric extraction system

Holetherm CC 100-150

Gas type

G25.3

G20/25

G20

G20/25

Pre-pressure in mbar

25

20

20

20/25

Country/Countries

NL

DE

AT/CH/CY/CZ/DK/EE/ES/FI/

FR/GB/GR/HR/IE/IT/LT/LU/ 

LV/NO/PT/RO/SE/SI/SK/TR/ 

DE/NL/PL/RO

BE/FR

Category

I

2

EK

I

2

(43,46-45,3 MJ/m

3

)

I

2

ELL

I

2

H/-/ I

2

E

I

2

E

+

Primary air

Open

Open

Open

Open

Pre-pressure

mbar

25

20

20

20

Burner pressure - high position mbar

13,8

13,2

13,2

13,2/16,63

Burner pressure - low position mbar

5,3

4,8

5,8

5,8/6,4

Injector orifice

Ø mm

2,3

2,1

2,1

2,1

Pilot light injector

CODE

51

51

51

51

Small position orifice

mm

1,7

1,7

1,7

1,7

Load Hs

kW

7,3

6,67

7

7

Hi load

kW

6,6

6

6,4

6,4

Gas consumption

m³/h

0,80

0,74

0,67

0,67

Nominal power - high position kW

5,2

4,8

5,1

5,1

Nominal power - low position

kW

2,6

2,6

3,1

3,1

NOx Hi

classe

5

5

5

5

Efficiency class NE613

2

2

2

2

Useful return (NCV) system**

For nominal heat output

%

79

80

80

80

For minimal heat output

%

76,5

76

77

77

Supplementary electricity consumption

Nominal

kWh

0

0

0

0

Stand-by

kWh

0

0

0

0

Energy efficiency***

Energy efficiency index

EEI %

79

80

80

80

Energy label

C

C

C

C

NOx Hs

mg/kWh

92

92

92

92

Heat output type/room temperature control

Indirect heat functionality

No

Single stage heat output, no room temperature control

No

2 or more manually-adjustable stages, no control of the room temperature

No

With mechanical control of room temperature by thermostat

No

With electronic control of room temperature

Yes

With electronic control of room temperature plus day-time switch

Yes

With electronic control of room temperature plus week-time switch

Yes

Other control options

Control of room temperature with presence detection*

Yes

Control of room temperature with open window detection*

Yes

With remote control option

Yes

* in combination with home automation
** shortest system path 
*** EU directive 2015-1186/1188

Содержание TL38FS

Страница 1: ...INSTALLATION INSTRUCTIONS FOR MODELS TL38FS ...

Страница 2: ...60 10 5 INSTRUCTIONS FOR THE MERTIK MAXITROL GV60 11 6 GAS TECHNICAL SPECIFICATIONS 12 7 CONCENTRIC PATHWAYS 14 8 CONCENTRIC FLUE SYSTEM 15 8 1 Components of the concentric flue system 15 8 2 Indirect direct façade connection if applicable See Chapter 8 15 8 3 Installation instructions regarding existing flues See Appendix 2 15 8 4 Parts 15 8 5 Installation 16 9 PASS THROUGH POSITIONS AND FUNCTION...

Страница 3: ... needs to be placed a minimum distance of 50mm from the wall unless stated otherwise in these instructions WARNING Gas fires become hot when in use After installation of the unit the glass surface is considered to be an active zone The glass surface can become very hot NOTE Therefore you should take care by for example keeping children and those requiring help away from the immediate vicinity of b...

Страница 4: ... the lower part outwards Both the upper and lower covers can be removed These are attached with 4 hooks per cover Use the swivel legs to ensure the fireplace is level Adjust the height between the mantle and the floor to 20 mm 2 Connection to the gas pipes 3 The cut out panel at the rear can be used to feed the gas pipe in 4 The concentric pathway can then be put in place see Chapter 7 Concentric ...

Страница 5: ...en possible to pull it down at an angle 7 Place the glass in a safe place so that it does not fall and or become damaged 1 upwards 2 outwards 3 down to remove Removing the side glass panes To remove the side glass panes for replacement the upper and lower covers must be removed The side glass panes are fixed with 6 bolts per panel 2 at the top 5 2 at the bottom 6 and 2 per window at the rear Loose...

Страница 6: ...e plane of contact with the front window 3 Clamp the side window s by tightening the glass holder screws or by installing the spring loaded glass holder Make sure the seals are complete intact and clean Place the front window and make sure it lines up with the side window s 4 Securely clamp the front window by tightening the glass holder screws 5 or by installing the spring loaded glass holder Loo...

Страница 7: ...d or baffle plate can be mounted inside the fireplace at the location of the flue gas duct J K Chapter 7 Concentric pathways contains a table that describes when a baffle plate and or a restriction must be put in place This is important to ensure the gas fire works correctly Before the lower cover is replaced the plinth needs to be put in place it is pushed around the legs and rests on the floor L...

Страница 8: ...he chips around the burner bed on the ventilation grid ensure even distribution here as well 2 Then put the ceramic wooden blocks into place as shown in the photo 3 4 5 6 7 8 9 J K Handle the blocks carefully the ceramic material is very fragile for example if dropped or bumped Do this as accurately as possible incorrect placement of the blocks can negatively influence the flame and cause soot for...

Страница 9: ...4 6 8 5 7 9 11 10 B D E F G H C A Trimline 38 FS Installation instruction 9 ...

Страница 10: ...nition control type B6R R8P Wifi Ready Ignition Remote control and Piezo ignition Gas connection 3 8 External A Gas inlet B Gas burner outlet C Thermocouple connection D pilot light burner connection Unit category C11 C31 C91 Pilot Mertik SIT 3 flames Combustion gas outlet and combustion air inlet Concentric Ø100 Ø150mm WARNING Sealed parts must not be adjusted Adjustment screw burner pressure Mai...

Страница 11: ...antenna wire and that they do not cross each other The high voltage released during ignition may damage the sensitive receiver circuit of the antenna This could mean the unit becomes less responsive or totally unresponsive to commands from the handset NOTE Do not tighten the contact breaker and the thermocouple connection too tightly on the gas control block It is sufficient to tighten by hand and...

Страница 12: ... low position kW 2 6 2 6 3 1 3 1 NOx Hi classe 5 5 5 5 Efficiency class NE613 2 2 2 2 Useful return NCV system For nominal heat output 79 80 80 80 For minimal heat output 76 5 76 77 77 Supplementary electricity consumption Nominal kWh 0 0 0 0 Stand by kWh 0 0 0 0 Energy efficiency Energy efficiency index EEI 79 80 80 80 Energy label C C C C NOx Hs mg kWh 92 92 92 92 Heat output type room temperatu...

Страница 13: ...ass NE613 2 2 Useful return NCV system For nominal heat output 79 79 For minimal heat output 72 6 72 6 Supplementary electricity consumption Nominal kWh 0 0 Stand by kWh 0 0 Energy efficiency Energy efficiency index EEI 79 79 Energy label C C NOx Hs mg kWh 83 83 Heat output type room temperature control Indirect heat functionality No Single stage heat output no room temperature control No 2 or mor...

Страница 14: ...rom 2 meter Roof pass through with 90º slope E 1 12 0 3 From 2 meter 90 bend calculation length 2 metres length including roof or exterior wall outlets Always adhere to a starting length of 1 metre Ratio vertical horizontal X X1 X2 Y 2 1 Ration vertical horizontal X X1 Y 2 1 Restriction calculation 1071 Wall pass through 90 bend Remove the baffle plate and no restriction Note Only direct wall duct...

Страница 15: ...tant measures must be taken Determine the position of the unit and outlet and begin construction of the flue with the connection on the unit paying attention to the direction of installation and connecting the elements by means of clamp strips The fitted pipe can be used between the bends or when connecting to the unit If necessary use wall brackets to support the flue Mounting using the roof pass...

Страница 16: ...ate to the chimney coping watertight on the roof 8 using silicone sealant and stainless steel screws Install the roof pass through 9 and secure it in place using the supplied clamping strip 10 The slider 5 will protrude approximately 100mm underneath the flue or ceiling after installation Attach the inner mounting plate 4 gastight against the bottom of the structural flue or against the bottom of ...

Страница 17: ... 500 F Under a carport roof or balcony inside and outside corners 500 G From vertical ground pipes or drain pipes 300 H Inside and outside a corner 500 I Above an external gas pressure regulator 1000 Side of a gas pressure regulator 500 J Conflict distance façade outlet Room K Roof drain centre to centre 1000 L From the centre of both roof drains 450 M Two wall drains above each other 1000 N Two w...

Страница 18: ...mbustion air supply circuit 2 The seal of the pressure hatches at the top and bottom of the fireplace check the gasket 3 Check of the pressure hatches above and below 1 2 3 Can they open and close freely Is the gasket still intact 4 Correct operation of the gas control block and ignition of the burner Measuring nipples There are 4 measuring points on the unit 2 on the gas control block 4 and 2 at ...

Страница 19: ...mend our Thermocet Cleaner Remove frame with glass pane See Paragraph 2 2 Preparation and placement on page 3 Important After the first use there will be a white haze on the inside of the glass pane this white haze must be removed immediately after the first use when the unit has cooled down The higher the frequency of use the more often cleaning is required After more frequent use more frequent c...

Страница 20: ...t head Check distance is approximately 4mm 5 Pilot light difficult to ignite Gas supply pressure too high nervous flame Adjust gas supply pressure or adjust the pilot light pressure using the gas valve Gas supply pressure too low short flame Adjust gas supply pressure check gas pipes or adjust pilot light pressure using the gas valve Air in pilot light pipe flame on off Blow pipes through make air...

Страница 21: ...enings Check and clean with a vacuum cleaner or similar device Logs etc in wrong position Check and correct see instructions 11 Low main flame Gas supply pressure too low Check gas supply pressure and corrections Burner pressure too low Check burner pressure check instructions for correct values 12 No or little difference between high low settings for main flame Low position setting incorrect Chec...

Страница 22: ...190 618 385 1193 314 100 150 500 183 446 Trimline 38 FS Installation instruction 22 Appendix 1 DIMENSIONAL DRAWINGS Trimline 38 FS Mantle Measurements in mm ...

Страница 23: ...ate Renovation package 7 Existing flue 9 Clamping strap 10 Roof pass through 1 Clamping strap 3 Clamping strap 4 Interior mounting plate Renovation package 5 Sliding element Renovation package 6 Flexible hose stainless steel 2 Fitting piece S Roof pass through M Length section H Wall bracket C Wall bracket B Clamping strap A Connection piece I Length section G Length section D Length section N Ben...