8.0 TROUBLESHOOTING FLOW CHART - MERTIK GV60 

PAGE 16 

No 

ACTION 

 

 

 

POSSIBLE PROBLEM/

CAUSE

 

 

SOLUTION

 

 

 

 

 

 

 

 

 

6. 

 

 

NO 

 

Resistance in thermo current 

circuit too high.  

Check cables and connections 

in thermo current circuit.  

 

 

 

Solenoid drops 

(audible click)  

 

Not enough heat on 

thermocouple.  

Check position of pilot to 

thermocouple and intensity of 

pilot flame.  

 

Motor turns to main gas 
and pilot stays lit.  

 

 

 

Low voltage from 
thermocouple.  

Check connections and, if 
necessary, replace 

thermocouple.

 

Do not over 

tighten the connections!  

 

 

 

 

 

Short because thermocouple 

end is damaged.  

Replace thermocouple, do not 

overtighten the connections!  

 

 

 

 

 

 

 

 

 

 

NO 

 

IGN sequence stops.

 

No 

reaction to transmitter 

command (receiver does not 

react).  

Press RESET button, see 

instructions. 

 

 

 

 

 

 

Add ground wire between 

pilot burner and gas valve. 

 

              OK 

 

 

 

 

Do not coil the IGN cable. 

 

 

 

 

 

 

Shorten IGN cable if possible. 

 

 

 

 

 

 

 

7. 

Main burner is lit.  

 

NO 

 

Gas valve manual knob in 

“MAN” position.  

Turn knob to “ON” position. 

 

              OK 

 

 

 

 

 

8. 

Main burner stays lit.  

 

 

NO 

 

Too much / too little air 

flow / draft at pilot, blows 

out or is smothered.  

Check whether restriction 

plate has been correctly 

applied in unit, see 

instructions.

 

Poor flue 

location, check correctness of 

layout and connections.  

 

             OK 

 

 

 

 

 

9. 

Magnet unit drops while 

motor turns.

 

3 beeps. 

 

 

NO 

 

Receiver batteries low.  

Replace batteries, 1.5V AA 

quality alkaline!

 

 

 

 

 

 

 

 

 

 

System can be switched 

OFF via remote control. 

NO 

System can be 

switched OFF via 

ON/OFF switch. 

NO 

Short between TC and SW 

cable. 

Check connection to 

interrupter block. 

 

             YES 

 

            YES 

 

 

 

 

             OK 

 

            OK 

 

Replace gas valve. 

 

Содержание TL100P

Страница 1: ...INSTALLATION INSTRUCTIONS FOR MODELS TL100P TL120P TL140P ...

Страница 2: ... FLUE LAYOUT Page 10 7 0 CONCENTRIC FLUE SYSTEM Page 11 7 1 Components of the concentric flue system 7 2 Construction of concentric flue system 7 3 Installation instructions regarding existing flues 7 4 Components 7 5 Installation 7 6 Cleaning and maintenance 8 0 TROUBLESHOOTING FLOW CHART MERTIK GV60 Page 14 9 0 PROBLEMS AND POSSIBLE SOLUTIONS Page 17 APPENDIX 1 DIMENSIONAL DRAWINGS Page 18 APPEN...

Страница 3: ... with the manufacturer There will be air in the gas pipes when the unit is first used The gas pipes therefore need to be purged first Ignite the fire according to operating instructions and check whether the burner flame is uniform After the unit has been used for the first time you should remove any deposits resulting from running burning in the paint using a glass cleaner for heaters Distance to...

Страница 4: ...ly to the rear wall mounting material not included 4 The legs of the device can be adjusted Min 150 Max 455 5 The adjustable feet allow to refined adjustment of the appliance Build the gas cassette in the self assessed surround casing The distance between the gas cassette and the unit is determined by the cable lengths of which control cabinet to the pilot burner and the gas control etc Max 1500 m...

Страница 5: ...7 Now place the window in reverse order as described at 2 2 on appendix 3 2 5 Fitting the pebble set see appendix 6 Scatter vermiculite evenly over the burner tray Make sure the pilot light remains unobstructed Place a row of medium sized and large pebbles at the front of the burner plate Fill the burner tray with small and medium sized pebbles from the front to the rear Place the pebbles as close...

Страница 6: ...ront burner D Thermocouple connection E pilot burner connection Unit category C11 C31 C91 Pilot flame SIT 3 flames Combustion gas discharge and combustion air supply Concentric Ø130 200 mm PAGE 6 B C A E D Main valve knob Thermocouple c Pressure regulator Ignition connection Pilot gas adjustment MAN knob Side inlet Side outlet Bottom outlet Bottom inlet Inlet pressure Outlet pressure Thermocouple ...

Страница 7: ...For automatic start via the transmitter the receiver and the control the gas control valve should be switched The oval disk on the gas control block should be turned to the ON position The I 0 switch should to be set to I The ignition must be connected to the receiver box at the terminal SPARK The transmitter s contains the thermostat sensor system The transmitter operates best at 2 to 3 m from th...

Страница 8: ...0 25 G30 31 COUNTRY NL NO DK DE ES PT IE GB BE FR AT SI HU PL CY MT IT CH CZ SK SI NL NO DK DE ES PT IE GB BE FR AT SI HU PL CY MT IT CH CZ SK SI CATEGORY I2H I2E I2E I2ELL I2L I3B P I3 PRIMAIRY AIR 2xø6 5mm 2xø4 5mm 3xø16mm PRE PRESSURE MBAR 20 20 25 20 25 20 25 30 30 37 30 BURNERPRESSURE HIGH MBAR 11 14 14 17 18 13 8 BURNERPRESSURE LOW MBAR 9 11 3 10 4 10 5 13 10 5 INJECTOR SIZE Ø MM 2xø2 2mm 2x...

Страница 9: ...E LOW MBAR 13 2 16 6 11 8 11 8 14 4 INJECTOR SIZE Ø MM 2xø2 3mm 2xø1 45 INJ PILOTBURNER CODE 51 30 LOWSETTING SIZE MM 2 2 1 3 LOAD Hs KW 16 1 14 3 14 3 14 3 14 2 13 1 LOAD Hi KW 14 5 12 8 13 2 13 2 13 12 CONSUMPTION M h 1 53 1 58 0 41 0 41 0 53 0 49 NOM OUTPUT kW 12 10 7 8 8 8 8 10 8 10 Appliance has NoX Class 5 AT I2H I3B P BE I2E I3 DK I2H I3B P DE I2ELL I3B P FI I2H I3B P FR I2E I3 GR I2H I3B P...

Страница 10: ... meter RESTRICTION CONDITIONS ALL GAS TYPES Vertical lay out restriction 0 6 meter no 6 12 meter 50 mm Natural gas 5 5 metres wall terminal LPG max 3 metres wall terminal restriction 1m 90 gvl no 1m 90 2 0m gvl no 1m 90 5 5m gvl no 45 elbow calculation length 1 meter 90 elbow calculation length 2 meter Reduction from diameter 130 200 to 100 150 can be made see below C D and E examples recommended ...

Страница 11: ...should be cased if necessary Sufficient fireproof measures must also be taken when the flue is being mounted along flammable materials Determine the position of the unit and outlet and begin construction of the flue with the connection on the unit paying attention to the direction of installation and connecting the elements by means of locking bands An adjustable length can be used between the ben...

Страница 12: ...ough the existing duct Attach the adjustable pipe 5 to the bottom of the flexible hose and secure this in place using 2 parkers Level the bottom side of the adjustable pipe 5 with the ceiling of existing chimney Shorten the flexible hose to approximately 100 mm above the existing chimney top Attach the mounting plate connecting piece 7 to the flexible hose on the roof Clamp it with a hose band and...

Страница 13: ...all bracket Elbow Floor ceiling support Fire stop plate flat Concentric element Wall bracket Floor support Fire stop plate flat Locking band 9 Roof terminal 8 Locking band 7 Chimney connection set Renovation kit 6 Flexible hose 316L 5 Slider Renovation kit 4 Connection set Renovation kit 3 Locking band 2 Adjustable length 1 Locking band ...

Страница 14: ...ns and label on receiver OK Transmitter receiver range limited 1 Move antenna cable see instructions 2 Replace receiver Optional wall switch cabling not operating properly Replace wall switch cabling Receiver fuse blown in older versions only Replace receiver 2 Magnet unit in gas valve is energised audible click NO No beep Impulse magnet not operating properly Replace gas valve NO 3 short beeps Re...

Страница 15: ...ton see instructions Add ground wire between pilot burner and gas valve Do not coil the IGN cable Shorten IGN cable if possible NO IGN sequence stops no pilot flame Transmitter command is possible IGN sequence stops no pilot flame Transmitter command is possible OK 4 Pilot lit NO TC and SW cable reversed Check connection of cable to receiver and interrupter see fig 1 Impulse magnet not operating p...

Страница 16: ...nsmitter command receiver does not react Press RESET button see instructions Add ground wire between pilot burner and gas valve OK Do not coil the IGN cable Shorten IGN cable if possible 7 Main burner is lit NO Gas valve manual knob in MAN position Turn knob to ON position OK 8 Main burner stays lit NO Too much too little air flow draft at pilot blows out or is smothered Check whether restriction ...

Страница 17: ...ize of the pilot flame cannot be adjusted there may be an obstruction in the pilot 2 Check whether the thermocouple interrupter is connected to the gas valve properly 3 Check that the gas valve is not faulty 4 Check whether the restriction plate has been placed according to instructions The main burner goes out when the unit is warm 1 This can be a normal effect of the thermostat Check whether the...

Страница 18: ...APPENDIX 1 DIMENSIONAL DRAWINGS PAGE 18 TL100p TL120p TL140p Ø130 Ø200 815 995 280 460 380 1015 1215 1415 1068 1268 1468 292 440 239 ...

Страница 19: ...APPENDIX 2 INSTALLATION EXAMPLES PAGE 19 1 2 3 3 MAX 1500 ...

Страница 20: ...APPENDIX 3 PREPARATION AND INSTALLATION PAGE 20 1 A ir B affle 2X 1 2 3 4 5 6 7 8 9 10 ...

Страница 21: ...APPENDIX 4 INSTALLATION OF GV60 GAS CONTROL PAGE 21 G A S V A LV E B U R N ER CO N TR O L G A S CA SSETTE 1 2 2 3 4 5 ...

Страница 22: ...APPENDIX 4 INSTALLATION OF GV60 GAS CONTROL PAGE 22 6 PO SITIO N PILO T B U R N ER U N D ER N EA TH TH E U N IT 7 8 9 ...

Страница 23: ...APPENDIX 5 CERAMIC LOG SET PLACEMENT PAGE 23 TL100p 2 2 2 4 3 1 1 5 5 1 1 2 2 2 3 4 5 5 ...

Страница 24: ...APPENDIX 5 CERAMIC LOG SET PLACEMENT PAGE 24 TL120p 3 3 3 3 4 1 1 2 5 1 1 2 3 3 4 5 2 2 3 3 ...

Страница 25: ...APPENDIX 5 CERAMIC LOG SET PLACEMENT PAGE 25 TL140p 3 3 3 3 4 1 1 2 5 1 1 2 3 3 4 5 2 2 3 3 5 5 ...

Страница 26: ...APPENDIX 6 ARRANGEMENT OF VARIOUS BURNER FILLINGS PAGE 25 PEBBLES 1 2 BASALT CARRARA 1 2 ...

Страница 27: ......

Страница 28: ...Brought to you by Imperial Point Express Trading Estate Stone Hill Road Farnworth Bolton BL4 9TN Tel 01204 868 550 Fax 01204 868 551 Email sales percydoughty com www visionfires co uk ...

Отзывы: