Technical data
Technisches Handbuch
Version 5.2
21
ERR Returns the last 10 errors
Read:
ERR
Answer: ERR<0..99,0..99, ……. ,0..99,0..99>
ErrorNo.
1
-
99 Overcurrent
Страница 1: ...Technical Manual VoE IOBox Rev 2 0 Article No 09V0002B Version 5 2 ...
Страница 2: ...ls Bildanalyse Systeme GmbH Heinrich Hertz Straße 7 68753 Waghäusel Germany Tel 49 7254 9351 0 Fax 49 7254 9351 200 www vision tools com info vision tools com Revision date July 2021 Version 5 2 Version change Log ...
Страница 3: ... 1 Appropriate use 5 3 2 Foreseeable misuse 6 4 Technical data 7 4 1 Dimensions mm 8 4 2 Plug Position 9 4 3 Status LEDs 9 4 4 Pin Assignment 10 4 5 Delivery status 11 4 6 Settings 12 4 6 1 Log 12 4 6 2 Bootloader 22 4 6 3 Calibration of analogue measurement 22 4 6 4 Change the IP address 23 4 6 5 Update firmware 25 4 6 6 Setting the IP address of the network adapter 26 4 6 7 Dim lights 28 5 Commi...
Страница 4: ...his manual All information and instructions are to be carefully read before use The manual is a product component and must be kept accessible to the plant operator at all times 2 3 Documents enclosed Manufacturer s declaration 2 4 Safety information In this manual icons acc to EN ISO 7010 are used to highlight correct text passages and relevant sections If the product is sold in a non EU country t...
Страница 5: ...information Follow the instructions In accordance with DIN EN ISO 7010 General warning sign In accordance with DIN EN ISO 7010 Warning of electrical voltage In accordance with DIN EN ISO 7010 Warning of oxidising substances In accordance with DIN EN ISO 7010 ...
Страница 6: ...It includes regulations and information that may not be duplicated distributed or transmitted in any other manner either in whole or in part Duplicating the manual within a company for the purposes of training by the operator is excepted Violations may have criminal consequences 2 7 Guarantee and Liability Our General Terms and Conditions apply Claims for a guarantee or for liability in case of pe...
Страница 7: ...d the outputs A1 0 A1 7 have a common GND potential as well as the inputs E2 0 E2 7 and the outputs A2 0 A2 7 The use of the VoE IOBox in combination with external clamping or relay boards requires professional installation in a closed control cabinet Therefore check the shielding capacity of the PC housing and cable shield before using the equipment Any other use or use beyond the scope of this d...
Страница 8: ...sionTools accepts no liability In case of changes or unauthorized modifications to the system any liability or guarantee from VisionTools Bildanalyse Systeme GmbH will cease to exist The electromagnetic behaviour of the system can be impaired by additions or changes of any kind Therefore make no changes or additions to the system without consulting with the company VisionTools Bildanalyse Systeme ...
Страница 9: ...X2 current max 12 A Inputs IN Type positive switching Voltage max 30 V Current 5 mA Connection type M12 Male Connector 4pos A Coded Outputs OUT 24 Type positive switching Voltage 24 V Current max 4 in total max 12 depending on the power supply A Connection type M12 Female Connector 4pos A Coded Outputs OUT PW Type push pull Voltage 24 V Current max 200 mA Frequency 1 5 kHz min pulse width duty fac...
Страница 10: ...uch Version 5 2 8 Power X2 Type Power supply Voltage max 30 V Current max 12 A Connection type M12 Male Connector 4pos T Coded Current drain without load idle approx 0 1 A Power consumption without load approx 2 4 W 4 1 Dimensions mm ...
Страница 11: ...s connected and supplied with power DATA Data transmission takes place or data packages are transmitted O1 24 O4 24 Outputs 1 2 3 or 4 are switched O1 PW O4 PW Outputs 1 2 3 or 4 were switched via the PWM duty factor IN1 IN6 Inputs 1 2 3 4 5 or 6 are switched PoE The power supply is via PoE 24V The power supply is via 24V ...
Страница 12: ...4V X6 Output M12 Male Connector 4pos T Coded PIN Signal 1 24V 2 GND 3 GND 4 24V M12 Female Connector 4pos A Coded PIN Signal 1 24V 2 GND 3 GND 4 PWM X3 Input X7 Output M12 Male Connector 4pos A Coded PIN Signal 1 INB 24V 2 INC 3 GND 4 INA M12 Female Connector 4pos A Coded PIN Signal 1 24V 2 GND 3 GND 4 PWM X4 Input X8 Output M12 Male Connector 4pos A Coded PIN Signal 1 INB 24V 2 INC 3 GND 4 INA M1...
Страница 13: ...ort 9760 To return the device to the delivery status the RESET button must be pressed until the LED on the left of the RESET button begins flashing Then adjust the IP address in the TCP IP Client Init object see chapter Change the IP address and briefly switch the box off NOTE Only the power supply may be connected for resetting The video How to reset the VoE IO Box mp4 serves as an additional hel...
Страница 14: ...ed All commands are sent in plain text ASCII Values begin with an angle bracket and end with an angle bracket Values are sent as decimal values in plain text ASCII If a command is not understood or is wrong the module sends ENR X 1 Example read out limit values of the outputs Command to read RCRL1 1 to 4 are the outputs of the VoE IOBox 2 Example read error Command to read ERR Result 99 over curre...
Страница 15: ...Gateway DNS1 DNS2 HostName E g CIP 00 04 A3 D0 00 00 192 168 0 10 255 255 255 0 192 168 0 1 0 0 0 0 VOE_HOST RVER Returns the program version Read RVER Answer VER vX XX XX UPL Upload Mode Send UPL Answer UPL vX XX XX The controller is set to upload mode for 4 seconds See Bootloader TEST starts and stops the test run Send TEST Answer TEST 1 Answer TEST 0 The controller is set to test mode CADC Cali...
Страница 16: ... any output 1 OUT1 2 OUT2 3 OUT3 4 OUT4 CFI1 0 4 0 4 0 1 0 999 0 Input static Output remains on as long as the input is present 1 positive edge Output switches on with rising edge for the time programmed with TMR1 2 negative edge Output switches on with falling edge for the time programmed with TMR1 3 positive edge Output switches on off with rising edge impulse relay 4 negative edge Output switch...
Страница 17: ...INP2 0 1 RINP3 Answer INP3 0 1 RINP4 Answer INP4 0 1 RINP5 Answer INP5 0 1 RINP6 Answer INP6 0 1 CFO RCFO Sets the outputs OUT1 4 Write CFO1 MODE Delay Answer none _CFO1 MODE Delay Answer ACK CFO1 0 1 0 9999 0 OUT1 24 Switch OUT1 PW PWM pulse width modulation 1 OUT1 24 PWM OUT1 PW off CFO1 0 1 0 9999 0 9999 ms Switch on delay OUT1 CFO2 x xxxx see CFO1 x xxxx CFO3 x xxxx see CFO1 x xxxx CFO4 x xxxx...
Страница 18: ...at Output OUT1 24 OUT2 x see OUT1 x OUT3 x see OUT1 x OUT4 x see OUT1 x Read ROUT1 Answer OUT1 0 1 ROUT2 Answer OUT2 0 1 ROUT3 Answer OUT3 0 1 ROUT4 Answer OUT4 0 1 OUTP Switches the outputs OUT1 4 with PWM value Write OUTPx STATUS PWM Answer none _OUTPx STATUS PWM Answer ACK OUTP1 0 1 0 100 0 Switches OUT1 off with CFO1 0 xxxx Output OUT1 24 is switched off and the PWM signal at output OUT1 PWM i...
Страница 19: ...nal at Output OUT1 PWM is output with CFO1 1 xxxx the PWM signal is output at Output OUT1 24 X no change at OUTx OUTP0 Simultaneous switching of outputs OUT1 4 with PWM value Write OUTP0 OUT1 PWM1 OUT2 PWM2 OUT3 PWM3 OUT4 PWM4 Answer none _OUTP0 OUT1 PWM1 OUT2 PWM2 OUT3 PWM3 OUT4 PWM4 Answer ACK OUTP0 0 X 1 0 100 0 X 1 0 100 0 Switches OUTx off with CFO1 0 xxxx Output OUT1 24 is switched off and t...
Страница 20: ...00mA Read RPSS1 Answer PSS1 0 1 RPSS2 Answer PSS2 0 1 TRG Software trigger for Outputs OUT1 4 Write TRG1 TIME Answer none _TRG1 TIME Answer ACK TRG1 0 9999 0 9999 ms Duty cycle for OUT1 with CFO1 0 xxxx Output OUT1 24 is switched on and the PWM signal at Output OUT1 PWM is output After the time has elapsed both outputs are switched off with CFO1 1 xxxx the PWM signal is output at Output OUT1 24 Af...
Страница 21: ...0 9999 RTMR4 Answer TMR4 0 9999 PWM RPWM Changes the brightness value Outputs OUT1 4 Write PWM1 brightness value Answer none _PWM1 brightness value Answer ACK PWM1 0 100 0 100 Brightness for Out1 PWM2 0 100 0 100 Brightness for Out2 PWM3 0 100 0 100 Brightness for Out3 PWM4 0 100 0 100 Brightness for Out4 Read RPWM1 Answer PWM1 0 100 RPWM2 Answer PWM2 0 100 RPWM3 Answer PWM3 0 100 RPWM4 Answer PWM...
Страница 22: ... 0 1 0 4000 RCRL4 Answer CRL4 0 1 0 4000 RCUR Reads the current of the supply and the outputs OUT1 4 Read RCUR0 Answer CUR0 0 12000 in mA RCUR1 Answer CUR1 0 4000 in mA RCUR2 Answer CUR2 0 4000 in mA RCUR3 Answer CUR3 0 4000 in mA RCUR4 Answer CUR4 0 4000 in mA CUR0 Total current CUR1 Current from OUT1 CUR2 Current from OUT2 CUR3 Current from OUT3 CUR4 Current from OUT4 RSPG Reads the voltages of ...
Страница 23: ...Technical data Technisches Handbuch Version 5 2 21 ERR Returns the last 10 errors Read ERR Answer ERR 0 99 0 99 0 99 0 99 ErrorNo 1 99 Overcurrent ...
Страница 24: ...ransmitted with the TFTP tool After 4 seconds the device is back in the normal operating mode 4 6 3 Calibration of analogue measurement Prerequisite An adjustable power supply with a max of 30V and 5A A precise load or an adjustable load for each output Measurement devices for current and voltage With this load exactly 1000mA at 24V should flow to the output Preparation Connect the voltage supply ...
Страница 25: ... the IP address from the V60 version 7 140 001 1 In the object VoE IOBox Init the IP address can be changed easily using the button change IP address V60 versions older than 7 140 001 1 Start the V60 and set up the objects TCP IP client Init and TCP IP client Send ...
Страница 26: ... IP client Send object Select the previously set up TCP IP client Init object and set the object type to character string under the character string 4 As a result the command to change the IP address is entered in the following format CIP IPAddr Mask Gateway DNS1 DNS2 HostName Example entry CIP 192 168 0 10 255 255 255 0 192 168 0 1 0 0 0 0 0 0 0 0 HOST_VOE 5 Process the objects TCP IP client Init...
Страница 27: ...e box Start the program Firmware update IOBox 2 7 from the driver CD 1 Enter the IP address of the VoE IOBox By default the IP address is entered as 192 168 0 254 2 Via the button query you can query the status of the current firmware version 3 Enter the path of the current firmware file elr4_v2 05 01 hex via the folder icon 4 Finally press the update button The upload mode is detected by the flas...
Страница 28: ... address of the network adapter 1 Open the network and sharing centre by right clicking on the network icon 2 Click on change adapter settings 3 Select the connected adapter and go to Properties 4 Scroll to the item Internet Protocol version 4 TCP IPv4 and click Properties ...
Страница 29: ...t an IP address which is located in the same network as the IOBox e g 192 168 97 1 and a valid subnet mask for example 255 255 255 0 Confirm with OK The IOBox and network adapter may have not the same IP address 6 The IP address of the IOBox is now changed ...
Страница 30: ...nical data Technisches Handbuch Version 5 2 28 4 6 7 Dim lights The connected lights can be dimmed in V60 via the object VoE IOBox set output For this purpose a duty cycle between 0 and 100 must be entered ...
Страница 31: ...Version 5 2 29 5 Commissioning 5 1 Assembly It is recommended that the VoE IOBox be mounted to a mounting plate This is then mounted on a mounting plate so that the fixing plate can be fixed to a profile Installation plate Mounting plate ...
Страница 32: ...rrect collection stations Your responsible administrative authority can give you more specific information on where authorized collection stations can be found NOTE Observe national regulations and internal operational solutions Dispose of the packaging of production materials including in the product cycle of the system appropriately Ensure appropriate separation and disposal ...
Страница 33: ...Notes Technisches Handbuch Version 5 2 31 7 Notes ...
Страница 34: ...Attachment Technisches Handbuch Version 5 2 32 8 Attachment ...
Страница 35: ...stitute was tasked with EMC testing The following standards were used for the assessment of the product with regard to electromagnetic compatibility DIN EN 61000 6 2 2005 as per VDE 0839 part 6 2 March 2006 as well as DIN EN 61000 6 3 2007 A1 2011 as per VDE 0839 part 6 3 September 2011 We point out that the manufacturer s declaration and thus the approval shall expire if this product is changed w...