TPD Series Interface Scale Operation Manual

- 15 -

8. SPECIFICATION

MODEL

TPD-12

TPD-30

TPD-60

Maximum
Capacity

12 lb / 6 kg / 192 oz

30 lb / 12 kg /480 oz

60 lb / 30 kg / 960 oz

Minimum
Capacity

0.04 lb / 20 g / 1 oz

0.1 lb / 40 g / 2 oz

0.2 lb / 100 g / 4 oz

Readability

0.002 lb/0.001 kg/0.05
oz

0.005 lb/0.002 kg / 0.1 oz

0.01 lb / 0.005 kg /
0.2 oz

Max. Divisions 1/6000
Weighing Units kg/lb/oz
Front Display

0.59inch /15mm digits LCD Display with white LED back Light

Rear Display

1 LCD Display with white LED back Light

Platter size

13.6 x 10.4 inch / 343 x 263mm

Housing

Plastic housing (steel base) with stainless steel pan

Interface

RS232 Output standard

Operation
Temperature

14°F - 104°F / -10°C - + 40°C

Power

Input AC 100-240V, output DC 12V/500mA
6V/3.2Ah rechargeable battery

Battery life

Approx. 48 hours with Bluetooth and backlight of continuous use
Approx. 52 hours with Bluetooth or backlight of continuous use
Approx. 68 hours without Bluetooth or backlight of continuous use

Keypad

3 membrane keys

Dimensions
(inch/mm)

13.6 (W) x 12.7 (D) x 18.9 (H) / 345 (W) x 322.5 (D) x 478.8 (H)

Net weight

10.1lb (4.6 kg)

Gross weight

11.5lb (5.2 kg)

Approvals

NTEP: Certificate No.22-010

Содержание TPD Series

Страница 1: ...TPD Interface Scale V1 1 ...

Страница 2: ...3 5 1 Switching on off 3 5 2 Zeroing 3 5 3 Using Tare 3 5 4 Select Weighing Units 3 5 5 Back light Setting 4 5 6 Power auto off 4 5 7 Bluetooth Operation Optional 5 5 7 1 Bluetooth Testing Tool Installation 5 5 7 2 CON1 Communication Protocol Testing 5 5 7 3 CON2 Communication Protocol Testing 7 5 7 4 ASK Command Testing 9 5 8 POS ECR protocol selection 11 6 PARAMETER SETTING 12 6 1 MENU BLOCK 13 ...

Страница 3: ...ator located back side of device Use the adjustable leveling feet located on the bottom of the scale until the bubble appears in the center of the indicator 2 3 Power Connection Connect the adaptor pin into the indicator adaptor jack Adaptor jack is locating below the left side of the scale Adaptor connects into your AC power socket Plugable equipment must be installed near an easily accessible so...

Страница 4: ...mpartment to avoid leakage Store the battery in a sealed bag or box in a dry temperate environment 3 KEYS DESCRIPTION 4 DISPLAY SYMBOLS CHARG E Charging indicator indicates scale has been connected with power STABLE Stable indicator Indicates the scale weight is stable NET Net indicator Indicates scale is displaying the net weight ZERO Zero indicator Indicates the scale is at zero kg Indicates the...

Страница 5: ...eed to press the calibration switch that is locating below the scale The weight of any container can be tared by pressing button so that with subsequent weighing the net weight of the object being weighed is always displayed Taring a container Load weight on the platform Press key Zero is displayed and tare is subtracted The indicator above Net indicator appears Remove weight on the platform Tared...

Страница 6: ...t to use or when weight is not in zero oFf Backlight function will be turned off on Backlight will be always turned on Note If battery is getting low the backlight function will not available 5 6 Power auto off 1 Press key during that start up display will be show F0 BL 2 Press key to select the menu until display show F1 OFF 3 Press key to confirm 4 Press key to select the options F1 OFF off To s...

Страница 7: ...Press key during that start up display will be show F0 BL 3 Press key until display show F2 COM 4 Press key to confirm display will be show BT 5 Press key to enter display will be show CON1 6 Press key to confirm display show F2 COM 7 Press key to select BACK option 8 Press key to confirm and back to normal weighing mode Testing steps in the mobile phone 1 Tab the connect button in your mobile pho...

Страница 8: ...TPD Series Interface Scale Operation Manual 6 ...

Страница 9: ... CON1 6 Press key to select CON 2 7 Press key to confirm display show STA 8 Press key to confirm 9 Press key to select BACK option 10 Press key to confirm and back to normal weighing mode Testing steps in the mobile phone 1 Tab the connect button in your phone to connect the Bluetooth module 2 Select the Unknown Service the last but one 3 Tab it and turn on the icon Once set it successfully The in...

Страница 10: ...TPD Series Interface Scale Operation Manual 8 ...

Страница 11: ...Press key to confirm display show F2 COM 8 Press key to select BACK option 9 Press key to confirm and back to normal weighing mode Testing steps in the mobile phone 1 Tab the connect button in your phone to connect the Bluetooth module 2 Select the Unknown Service the last but one 3 Tab it and turn on the icon Once set it successfully The indicator above Bluetooth indicator in the scale appears 4 ...

Страница 12: ...TPD Series Interface Scale Operation Manual 10 ...

Страница 13: ...M 4 Press key to confirm display will be show BT 5 Press key to select port option 6 Press key to confirm display show off 7 Press key until display show cas 2 8 Press key to confirm 9 If necessary Press key to select protocol from type 0 type 6 TYPE 0 2 4 5 6 10 Press key to confirm display show F2 COM 11 Press key to select BACK option 12 Press key to confirm and back to normal weighing mode ...

Страница 14: ...nu Press it can confirm which will be shown displayed Select the Menu Press key to choose menu block one by one Return to Weighing Mode Press key to select BACK option in parameters to escape from the menu and back to normal weighing mode To access the technical parameters F4 TARE TECH it s required to press the calibration switch switch is locating below the scale ...

Страница 15: ...sk Ask mode 1 Command W read data 2 Command TARE Tare 3 Command ZERO Zero off Bluetooth Communication port off CAS 2 N A Port CON1 Continuous Protocol 1 CON 2 COUT Continuous Protocol 2 STA Send stable weighing data CAS ACT CAS Active Protocol PAS CAS Passive Protocol ask Ask mode 1 Command W read data 2 Command TARE Tare 3 Command ZERO Zero off RS232 Communication port off CAS 2 Type 0 CAS POS EC...

Страница 16: ... the local gravity P5 sta On Multi Tare operation enable OFF Multi Tare operation disable BACK Escape from setting menu and back to normal weighing mode Note To calibrate in kg or lb unit capacity will be show in kg or lb values Default setting is marked by 7 DIAGRAM Serial interface 9pin D Connector Scale Computer Pin 2 Pin 3 Pin 3 Pin 2 Pin 5 Pin 5 Pin 2 RXD Input Receiving data Pin 3 TXD Output...

Страница 17: ...ay with white LED back Light Platter size 13 6 x 10 4 inch 343 x 263mm Housing Plastic housing steel base with stainless steel pan Interface RS232 Output standard Operation Temperature 14 F 104 F 10 C 40 C Power Input AC 100 240V output DC 12V 500mA 6V 3 2Ah rechargeable battery Battery life Approx 48 hours with Bluetooth and backlight of continuous use Approx 52 hours with Bluetooth or backlight ...

Страница 18: ...TPD Series Interface Scale Operation Manual 16 9 DIMMENSIONS inch mm ...

Страница 19: ...error Zero setting range exceeded due to switching on 4 max Make sure platform empty Err 6 A D value out of range Make sure platform empty and check the pan is installed proper Check the load cell connectors ol Over range Remove the load Re calibrate fail Calibration Error Check the calibration weight and re calibrate ...

Страница 20: ...TPD Series Interface Scale Operation Manual 18 ...

Страница 21: ...TPD Series Interface Scale Operation Manual ...

Отзывы: