background image

                                                                                                                               

 

Content 

 

Appendix 1:    Printing format 
Appendix 2:    Exporting data to PC in the form of EXCEL 

Appendix 3:    U.KEY Conector

 

 
 
 

1. Introduction

 

…………………………………………………………………….….….1 

 

2. Precaution

……………………………………………………....................................1 

 

3. Before Using the Product 

3-1 Unpacking and 

Checking………………………………………………….……….…...1 

3-2 Installing Components.

……………………………………..……………………….…..1 

3-3 Leveling 

the Scale………………………………………..…………………….….........1 

 
 
 

   

     

4. Product Introduction 

4-1 

Specifications & General Features ………………………………………….…………2 

4-

2 Front Panel …………………………………………………………………….…………3 

4-2-

1 Display …….……………………………………………………… ………….…….....3 

4-2-

2 Keyboard…………………………………………………………………….……….....4 

4-

3 Power Supply……………………………………………………….......…….…….…….5 

5. Setting Mode 

5-1

 

Function Setting

………………………………………….…………………………….…5 

5-

2 Parameters………………………………………….……………………………….....…6 

6.

 

Single and Multi-point Calibration

………………………………….…....…….8

 

7. Operation 

7-

1 Weighing………………………………………………………………………………..…9 

7-

2 Tare & Preset Tare……………………………………………………………….….……9 

7-3 

Checking function

   

7-3-1 Upper & Lower Weight Limit Checking 

………………………………………..……10 

7-3-2 Upper & Lower Quantity Limit Checking 

….…………………………………...……11 

7-4

 Basic Counting

 

7-4-

1 Entering a Known Unit Weight and Unit weight Memory………………….………12 

7-4-

2 Sample Counting and ACAL………………………………………………………….13

 

7-5 Accumulation, Accumulation Display and Accu

mulation Clear………………..........13 

7-

6 Initialization of the Scale to Printer (Optional)……………………………….……..…14 

7-

7.The Control from PC to Scale (Optional)…………………………………….……..…15 

8. Serial Interface 

8-1 RS-

232 Connector……………………………………………………………………….15 

 
 

9. Troubleshooting and Error Message

……………………………………...…15

 

 

Summary of Contents for JCN

Page 1: ...e 5 1 Function Setting 5 5 2 Parameters 6 6 Single and Multi point Calibration 8 7 Operation 7 1 Weighing 9 7 2 Tare Preset Tare 9 7 3 Checking function 7 3 1 Upper Lower Weight Limit Checking 10 7 3 2 Upper Lower Quantity Limit Checking 11 7 4 Basic Counting 7 4 1 Entering a Known Unit Weight and Unit weight Memory 12 7 4 2 Sample Counting and ACAL 13 7 5 Accumulation Accumulation Display and Acc...

Page 2: ...cale in water or other liquids Service should be performed by authorized personnel only 3 Before Using the Product 3 1 Unpacking and Checking Open the package and check the instrument for transport damage Immediately inform your dealer if you have complaints or if parts are missing The package should contain Scale body User manual Weighing pans Adaptor 3 2 Installing Components 1 Before using the ...

Page 3: ...d linear calibration available HI OK LO quantity checking function Weighing platter easy to disassemble with dust proof PVC cover Low battery and charging status indication Accumulation of weight and quantity RS 232 port and RELAY port optional for external devices Model JCN 3K JCN 6K JCN 15K JCN 30K Capacity kg 3 6 15 30 Weighing units Kg g lb Display LED backlit displays 6 5 6 Digits Pan size 29...

Page 4: ...e top of STABLE when scale is in stable condition 9 ACAI Symbol points at ACAI when the average unit weight is calculated or recalculated 10 M Symbol points at M when scale is in accumulation mode 11 UW Under entering a known unit weight mode Symbol points at UW when entered unit weight is lower than 4 5 of scale division Unit weight is too small for ensuring accurate quantity calculations 12 SMPL...

Page 5: ... 7 M HI key Clear the input figures Set the value of HI Enable the blinking figure plus one when inputting the figures 8 ZERO ESC key Zero the display within 2 of max capacity or cancel Tare action Exit from the setting without saving 9 MR key Recall and display the total Accumulation data weight total count and number of weightments and the first 10 records in details Circle the choices in the se...

Page 6: ...y can operate the scale for approximately 65 hrs with backlight 80hrs without backlight Note Battery is to be replaced only by an authorized service dealer Risk of explosion can occur if replaced with the wrong type or connected improperly 5 Setting Mode 5 1 Function Setting 1 Press G N SET key while powering on Or long press G N SET key in the weighing mode to enter parameter setting 2 Press key ...

Page 7: ...o save the setting then press MR or TARE to advance to next parameter setting 4 SET03 zero range setting d0 d1 d2 d3 d4 d5 d0 one division d1 2 divisions d2 3 divisions d3 4 divisions d4 5 divisions and d5 6 divisions 5 SET04 whether to save the upper lower limit of quantity checking on off OFF previously set quantity checking values are not retained when the unit is turned on ON previously set qu...

Page 8: ... printer paper size 5cm 3cm ZEBRA Zebra printer paper size 5cm 3cm GP Adhesive sticker label printer paper size 5cmx3cm DMP Dot matrix printer SH 24 CK thermal printer Chinese available ET Large LED display CX CX large screen display version 0 02 EXCEL Work with the function of Use Serial Keys in Windows in outputting the data to Excel Reference user manual http www jadever com cn Download aspx U ...

Page 9: ...when powering on again 15 SET14 the kinds of checking Qty ck Wt ck Qty ck start amount checking Wt ck start weighing checking 16 SET15 parameter initialization press key G N SET then key M SAVE to start initialization It is finished when displaying OK 6 Single and Multi point Calibration Note Before calibration please set the capacity first The unit used in calibration is the one that has been set...

Page 10: ...ill show the total weights value Press TARE to complete Repeat this step to complete the calibrations of on3 on4 and on5 6 Press ZERO ESC to save After the window displays It will return to normal weighing mode Note the window displays automatically when on5 is finished It will be saved and return to the normal weighing 7 Operation 7 1 Weighing Put item to be weighed on the scale The Weight window...

Page 11: ... 2 1 Enter the tare value by pressing the numeric botton the screen will show the tare value then press TARE 2 Put the items into the container and the weight of container will be tared automatically from the total weight 3 To cancel tare action clear the pan and press TARE or ZERO ESC 7 3 Checking function 7 3 1 Upper Lower Weight Limit Checking Upper weight limit 1 Long press key M HI under the ...

Page 12: ...igher than Hi value then the Hi value will become the same value as Lo data 7 3 2 Upper Lower Quantity Limit Checking Upper Quantity Limit 1 Long press key M HI under the weighing mode The number leftmost is blinking 2 Press key MR or TARE to shift and key M HI or PRINT LO to modify the value or via numeric keys 3 Press key G N SET to start or close weighing checking 4 Press key M SAVE to confirm ...

Page 13: ...ymbol points at UW when entered unit weight is lower than 4 5 of scale division Unit weight Memory 1 When there is one unit weight on the screen and press UWS ITEM key 2 Then enter a number for each unit weight Use MR or TARE key to shift and M HI or PRINT LO key to modify the value or via numeric keys 3 Press key M SAVE to confirm and save Press key ZERO ESC to return to weighing mode without sav...

Page 14: ...e is a risk of inconsistent piece weights or if the reference weight is close to the minimum ACAI uses an initial averaging unit weight to count additional pieces that are placed on the scale After a few seconds the scale gives a beep as the new higher reference weight is used to recalculate the averaging unit weight The process can be repeated as long as the additional weight is less than the pre...

Page 15: ... Press key MR or TARE to check the total events and the first 10 accumulation events in detail 3 When connecting PC printer DMP or CK press PRINT LO to output the events Note XX total accumulation events XX the single accumulation Accumulation clear To clear the total accumulation data or the first 10 accumulation events press key MR or TARE to shift the events and then press key M HI to clear Sym...

Page 16: ...1 Connect the indicator and computer Step 2 Open the serial port to modify Input the letters Z T C R and P in the sending window and press key Send again The scale can conduct the responding function Z Zero T Tare R and P Printer C Cancel Tare 8 Serial Interface If external interface is needed please select the proper RS 232 board firstly and only when this board is adopted the functions can be en...

Page 17: ... EEPROM Chksum failure Re weld EEPROM or contact the maintenance department ERR5 Overload condition Remove the overload item ERR6 Exceeds the display range ERR7 Accumulated number of weighments exceeds the display range Delete the exceeding weights ERR8 Weight limit value is higher than the full load value Reset the weight limit value ERR9 Exceed tare or pre tare range 0 Tare value full load ERR10...

Page 18: ...Appendix 2 Exporting data to PC in the form of EXCEL Introduction Connect the scale with PC and set the parameter of external device as EXCEL on the scale then you could export the weighing data to PC in the form of EXCEL With this function you could record accumulate average data statistical analysis the testing data which we could call it as scale computer data management function Note pls enabl...

Page 19: ...ibility Options enter General option choose Use Serial Keys and press Settings In the dialog box Settings for SerialKeys set the corresponding Serial port and Baud rate which should be same as Baud rate in scale 3 Test if Serial Keys works well Open a Text Document and press the Print buotton on the scale The Serial Keys works well if pc exports the weighing data to Text Export weighing data to Ex...

Page 20: ...d export the weighing data to PC in the form of EXCEL With this function you could record accumulate average data statistical analysis the testing data which we could call it as scale computer data management function Most importantly you don t need any setup in computer but only use U KEY connector to link computer system directly such as EXCEL Express System ERP system and so on This connector i...

Page 21: ... digit should be 0 for total column 三 Setting 1 Prepare one computer with windows2000 xp Vista win7 win8 Linux system or Android pad 2 Scale setting PERI U KEY External devices BAUD 9600 Baud PRT M KEY STABLE Print Mode RTC ON OFF Time 3 Open the receiving port such as EXCEL or ECR system and the weighing data will show on the position where the mouse cursor in 四 Example 1 EXCEL 2 ERP System ...

Reviews: