15

 

Installation Camera with Brackets

 

 

Installation using Ceiling Mount Bracket 
 

 Remove the ceiling tile from the ceiling and cut 

a hole whose diameter is 30~40mm on the ceiling 

tile to pass the wire(s) and cable(s) through to the 

upside of the ceiling. (In case of the wiring and 

cabling through the mounting surface only) Then 

prepare the ceiling mount bracket. Pull the wire(s) 

for the system as below. (Anchor Bolt 3/8"

×

70)  

 

 Hook up “Drop Prevention Spring” on main 

body to prevent camera from unexpected drop 
and pull the wire(s) and cable(s) for the system 
as below 

 

 Line up the mold lines and assemble main 

body to mount adaptor and turn it. And 

assemble the main both with the camera 

mount adaptor with the screws. (Torx screw 

M4X18). Please make sure the screws are 

tightly assembled for waterproof. 

 

 

 

 

 

 

 Screw the dome cover to the main body and 

remove the protection vinyl from the dome 

cover. 

 

Notice 

z

 

Before starting the installation, make sure that the Camera ID and Protocol are set up properly. 

z

  To adjust the installation height from the mounting surface, the pipe and coupler should be 

needed between the surface mount part of the ceiling mount bracket and the camera mount part 
of the ceiling mount bracket. Note that they are not supplied by the manufacturer.  

 
 
 
 

Содержание VPD200SM2i

Страница 1: ...Page 1 HA VPD2 15 RDW 200SM2i WARE FULL INSTA HD NETW TALLA WORK PT ATION TZ Came Rele N GUI ra eased on 1 Vision DE Version 1st of June n Hitech C n 1 0 0 e 2012 Co Ltd ...

Страница 2: ...with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to ...

Страница 3: ... content Hardware Installation Guide 1 Precautions 4 2 Limitation of liability 4 3 Disclaimer of warranty 4 4 Package Contents 5 5 Cable Connection 6 6 Installation 7 13 7 Dimension mm 14 8 Specification 14 VPD200SM2i 15 ...

Страница 4: ...Be careful not to be stained by fingerprint z Don t face the camera directly toward sunlight or sunlight reflecting area CCD may go defective at this condition z Please give a special attention to keep the unit from dangerous drop or external shock during the process of transportation or handling z Never try to touch the camera in wet hand It may cause an electric shock z Do not expose the camera ...

Страница 5: ...tem combined by the devices of third party 6 Any claim or action for damages brought by any person or organization being photogenic subject due to violation of privacy with the result of that surveillance camera s picture including saved data for some reason becomes public or is used for the purpose other than surveillance 4 Package Contents Note Mount Brackets are optional z Wall Mount Bracket z ...

Страница 6: ...picture for further tasks Mounting Screw Hole This hole is for screws that assembles the main body with a bracket IP Reset Switch Reset its network configuration to the factory defaults You will lose all data that had been entered previously To initialize the system to the factory default press the reset button for more than 5 seconds LAN Port Used for the Ethernet connection Audio Port Used for t...

Страница 7: ...N 1 2 3 4 5 6 7 8 z ID numbers of camera are set up with binary numbers See the examples shown below Pin 1 2 3 4 5 6 7 8 ID Value 1 2 4 8 16 32 64 128 ex ID 5 on off On off off off off off ex ID 10 off on Off on off off off off z The camera ID range is 1 255 Camera ID must not be 0 z Factory default of Camera ID is 1 z Match the camera ID with Cam ID setting of your DVR or Controller to control th...

Страница 8: ...OFF ON OFF PELCO P 4800 bps ON ON OFF PELCO P 9600 bps Otherwise Reserved z If you want to control using DVR or P T controller their protocol must be identical to camera Otherwise you can not control the camera z Adjust the DIP switch after turning off the camera If you changed the camera protocol by changing the DIP switch the change will be effective after you reboot the camera z Factory default...

Страница 9: ...and cable s for the system as below Line up the mold lines and assemble main body to mount adaptor and turn it And assemble the main both with the camera mount adaptor with the screws Torx screw M4X18 Please make sure the screws are tightly assembled for waterproof Screw the dome cover to the main body and remove the protection vinyl from the dome cover Notice z Before starting the installation ma...

Страница 10: ...ce Hex Lag 14 50 Hook up Drop Prevention Spring on main body to prevent camera from unexpected drop and pull the wire s and cable s for the system as below Line up the mold lines and assemble main body to mount adaptor and turn it And assemble the main both with the camera mount adaptor with the screws Torx screw M4X18 Please make sure the screws are tightly assembled for waterproof Screw the dome...

Страница 11: ...wn RS485 3 Red DC 12V 4 Orange Ground 5 Yellow OUT COM Relay Output Common 6 Green OUT 2 Relay Output 2 7 Blue OUT 1 Relay Output 1 8 Violet IN COM Sensor Input Common 9 Gray IN 1 Sensor Input 1 10 White IN 2 Sensor Input 2 z Audio Cable Port Pin Number Connector Wire Color Signal 1 RCA Yellow Audio IN 2 Audio GND 3 RCA White Audio OUT ...

Страница 12: ...C coaxial cable Connecting Audio Audio is full duplex It is possible to set the mode as Tx only Rx only or Tx Rx 1 Connect audio input and output ports to audio devices accordingly 2 The Audio signal required is line level so an audio equipment with an amp mixer or other amplifier should be used Connecting Serial Port RS 485 Communication z For PTZ control connect the cable s to your keyboard or D...

Страница 13: ...of the decoder system works in pass through mode That is data from at one port is delivered to the other port vice versa Connecting Sensor and Alarm Connect sensor and alarm devices to corresponding terminals accordingly z Sensor Input z Relay Output Maximum allowable electrical load of relay is shown bellow table Drive Power DC Power AC Power Max Load Max DC 24V 1A Max AC 125V 0 5A IN COM IN 1 IN...

Страница 14: ...ual Bright Shutter Priority Iris Priority Spot GAIN Control Auto Manual 3 28dB Shutter Control Auto Manual 1 1 1 10 000 sec WhiteBlance Auto Manual Red Blue Gain Adjustable Video Compression H 264 baseline profile Motion JPEG Resolutions Up to 1920 x 1080 Frame rate H 264 Up to 15fps with 1920x1080 MJPEG Up to 30fps with 720p resolution Video streaming Support multi stream with H 264 MJPEG Adjusta...

Страница 15: ...tp e mail Notification via email FTP and TCP Video buffer 16MB pre alarm and post alarm Recording Save to Micro SD card with event mode and continuous mode Firmware upgrade Remote upgrade via network API CGI Interface document ActiveX Interface ocx dll document Physical RESET Button 1 x Factory Reset Button Power Source DC 12V 5 0A Power Consumption Max 36W Weight Appr 3 800g Wall 3 200 g Ceiling ...

Отзывы: