1. Precautions

 

 

 

   

Please read the manual carefully before the installation in order to set up the camera correctly and to 
obtain the best picture quality. 

 

 

Please keep the manual in good condition for your future reference and service application. 

 

 

Installation and services should be only carried out by an authorized personnel according to local safety 

regulations. 

 

 

If any liquid or solid matter gets into the housing, immediately disconnect the camera from power supply 
and have it checked by your authorized dealer before reusing. 

 

 

Avoid installing the camera at extremely hot or cold places. 

 

 

If you are not a certified person, never try to dismantle the camera. To avoid electric shock, never remove 
the screws or covers. There are no parts inside that need maintenance by the user. All maintenance should 
be carried out by qualified personnel. 

 

 

Avoid installing the camera at a place of high humidity. 

 

 

Avoid installing the camera at the place exposed to gas or oil. 

 

 

Keep the top glass of the lens always clean in order to obtain the best picture quality all the time. Be 
careful not to be stained by fingerprint. 

 

 

Don't face the camera directly toward sunlight or sunlight reflecting area. 

CCD may go defective at this condition. 

 

 

Please give a special attention to keep the unit from dangerous drop or external shock during 

the process of transportation or handling. 

 

 

Never try to touch the camera in wet hand. It may cause an electric shock. 

 

 

Do not expose the camera to radioactivity. It causes a serious damage on the CCD. 

Содержание VC58S

Страница 1: ...1 version 1 0 1 WDR True Day Night Box camera INSTRUCTION MANUAL 12VDC 24VAC Please read this manual carefully before installation and operation of the product ...

Страница 2: ...ance INFORMATION This equipment has been tested and found to comply with limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accor...

Страница 3: ...tions 4 2 Limitation of liability 5 3 Disclaimer of warranty 5 4 Package 6 5 Special features of the model 7 6 Name and function of each part 8 9 7 Installation 10 12 8 Troubleshooting 13 14 9 Dimension mm 14 10 Specification 15 OSD Manual For function control 1 8 ...

Страница 4: ... the camera To avoid electric shock never remove the screws or covers There are no parts inside that need maintenance by the user All maintenance should be carried out by qualified personnel Avoid installing the camera at a place of high humidity Avoid installing the camera at the place exposed to gas or oil Keep the top glass of the lens always clean in order to obtain the best picture quality al...

Страница 5: ...mited to below 1 Any damage and loss including without limitation direct or indirect special consequential or exemplary arising out of or relating to the product 2 Personal injury or any damage caused by inappropriate use or negligent operation of the user 3 Unauthorized disassemble repair or modification of the product by the user 4 Inconvenience or any loss arising when images are not displayed ...

Страница 6: ...6 version 1 0 1 4 Package Camera x 1 Instruction manual x 1 OSD manual x 1 Auto Iris Plug x1 C Mount Adaptor x 1 RS 485 Lead Wire x 1 ...

Страница 7: ...ity With this special technology it provides remarkable low light sensitivity of 0 1Lux F2 0 0 0001Lux w 512x Sens up which is as much as 3 times better than conventional WDR cameras 4 2D 3D Noise Reduction 2D 3D DNR compliments the new WDR technology to provide clear low noise images 2D 3D filtering reduces noise which can save the hard drive space on your DVR 2D DNR helps preserve edges in the p...

Страница 8: ...ack focus adjustment Knob Fine tune the Back Focal Length 6 3 Bottom Fixture 1 4 20 mounting thread Fixture can be separated and attached on the bottom side as well Please use the supplied clamp screws only to change the position of the bracket Using screws more than 5mm depth can do a serious damage to the inside of this camera Use an international standard 1 4 20 mounting screw to install the ca...

Страница 9: ...r side Power indicator OSD function control key Video out BNC RS 485 Power In Non polarity Power indicator Red LED ON when camera s operational OSD function control key VIDEO OUTPUT BNC Female POWER INPUT Power input terminal ...

Страница 10: ...clear Clean dirt or water drops with soft cloth in order to avoid the picture blooming or reflection 7 2 When using an auto iris lens DC drive 1 Please take off the sleeve outer cable of the lens by 10mm 2 Please take off the sleeve inner cable of the lens by 2mm Pin No Lens DC No 1 Pin Damping No 1 Pin Damping No 1 Pin Drive No 1 Pin Drive 3 Solder the wires on the pin connector iris jack supplie...

Страница 11: ... lens by turning it clockwise When used with an Auto Iris lens please insert the iris jack into the Iris socket which is located on the right side of the camera Please set the lens selection to DC on the OSD setting Caution Use the lens as shown in the picture here When the lens is out of the spec it could damage the camera inside or may not be correctly fitted with the camera Use the lens less th...

Страница 12: ... Hi z position for the interim equipment Locate the switch to 75Ω for the last equipment 7 7 Power Please check if the model is 12VDC or 12VDC 24VAC Dual power before the installation Please refer to the voltage description on the rear panel to choose the right power source 12VDC camera Please make sure to use a UL CE approved and 12VDC 500mA regulated power supply 12VDC 24VAC Dual power camera Yo...

Страница 13: ...n the screen is dark Adjust the contrast feature of the monitor If you have an intermediate device set the 75Ω Hi Z properly Please check the impedance The camera is not working properly and the surface of the camera is hot Please check that you have properly connected the camera to an appropriate power source The DAY NIGHT menu does not work Please check if DAY NIGHT menu is set to AUTO2 The SENS...

Страница 14: ...mmunication setup matches between camera and OSD Controller or DVR RS 485 Communication establishment initial value Item Camera ID BAUD RATE UART MODE RET PKT Initial value 1 9600 8 NONE 1 ENABLE We recommend that you make ground connection between camera and controller for safe communication control When RS 485 cable is not properly connected A warning message ERROR RS 485 Connection Please recon...

Страница 15: ...0 90 000sec PAL 1 50 90 000sec Gamma control Standard γ 0 45 White Balance 1500 K 11 000 K Auto ATW Col Roll PUSH MANUAL Gain control Standard 6dB 34dB Auto Maximum by OSD Smear effect 0 005 Power source 12VDC 24VAC Operating current 200mA 12VDC 100mA 24VAC Iris control DC MANUAL Operating temp 10 C 50 C Humidity 0 RH 90 RH Measurement mm 66 V x 57 H x 126 5 D Weight Approx g 550 Function WDR Off ...

Отзывы: