background image

LDLF30x120-B470/24V/-a

Information about the Instructions of Use

1.2 Improper Use

All unintended use and all device-related activities not described in these

instructions of use is to be deemed as unauthorised misuse outside the legal

limits of indemnity of the manufacturer.

Reasonably foreseeable misuse is:

Non-compliance with the instructions for use,

Faulty operation,

Operating by personnel not qualified or instructed,

Operating the device if it is not in a proper technical condition,

Operating the device in ambient conditions differing from the corresponding

specifications in the instructions of use

Operating the device with voltages differing from the corresponding

specifications in the instructions of use,

Using spare parts which are not original parts from the manufacturer,

Using incompatible accessory components,

Improper maintenance and repair works,

Unauthorised modifications to the device.

1.3 Qualified Personnel

The device may only be assembled, commissioned, operated, maintained,

installed, set up, cleaned, repaired and transported by qualified skilled

personnel.
A qualified person is deemed to be someone who has been trained and

instructed for his/her activities with the device, and who has proven his/her

capability to the purchaser. The operating personnel must be authorised by the

purchaser for those activities at the device.
For the installation and operation of the device, the skilled personnel must

know and comply with the applicable guidelines and standards for handling

control equipment, electrical installations and working materials.

© Vision & Control GmbH 2019

999.995.600.10-en-1.0

7

Содержание 1-43-401

Страница 1: ...ns for Use LDLF30x120 B470 24V a LED bar light diffuse illumination Luminous colour Blue 470 nm Instructions for Use LDLF30x120 B470 24V a LED bar light diffuse illumination Luminous colour Blue 470 n...

Страница 2: ...this document on to third parties reproduce and communicate its contents in as far as this has not been expressly authorized Offenders will be liable for damages All rights are reserved with respect...

Страница 3: ...0 B470 24V a 1 43 401 Product Identification Designation Description LDLF LED bar light diffuse illumination 30x120 Dimensions light emitting surface 30 mm x 120 mm B470 Wavelength Blue 470 nm 24V 24...

Страница 4: ...ption 12 4 1 Device Views 12 4 2 Notices on the device 13 5 Technical Data 14 5 1 General Parameters 14 5 2 Electrical Parameters 16 5 3 Photometric Parameters 17 5 4 Conditions for Operation Storage...

Страница 5: ...LDLF30x120 B470 24V a Vision Control GmbH 2019 999 995 600 10 en 1 0 5...

Страница 6: ...future reference 1 1 Intended Use The device is intended exclusively for use as a lighting element for industrial image processing in automation technology The device is not suitable for use in poten...

Страница 7: ...ions of use Using spare parts which are not original parts from the manufacturer Using incompatible accessory components Improper maintenance and repair works Unauthorised modifications to the device...

Страница 8: ...nual and rejects any warranty derived therefrom Within the bounds of the legal requirements the manufacturer shall only be responsible for the technical safety characteristics of the device if the mai...

Страница 9: ...ces of the danger These measures must be taken DANGER Indicates an imminent danger with high risk resulting in severe injuries or death if not avoided WARNING Indicates a hazardous situation with medi...

Страница 10: ...vice and the connected technical equipment Hazards going beyond the general safety instructions are referred to separately at the relevant points in this manual CAUTION Risk of injury due to electric...

Страница 11: ...11 Cable with M8 socket 4 pin straight 2 m 1 11 612 Cable with M8 socket 4 pin straight 3 m 1 11 613 Cable with M8 socket 4 pin straight 5 m Connection cable with 4 pin M8 socket and open cable end wi...

Страница 12: ...vice Views 1 5 3 4 2 Image 1 Device view 1 Light emitting surface 2 3 x M3 mounting hole depth 10 5 mm on both sides 3 4 x M3 mounting hole depth 4 5 mm on both sides 4 Casing 5 Connection cable with...

Страница 13: ...ices on the device Following instructions are provided on the device Type plate Type XXXXXXXXXXX No XXXXXXXX 1 3 2 Image 2 Type plate 1 Device designation 2 Manufacturer information 3 Serial number Vi...

Страница 14: ...anodised Optical material PMMA Housing dimensions 35 mm x 142 mm x 22 mm without connector Dimensions light emitting surface 30 mm x 120 mm Weight 160 g Degree of protection IP IP 50 Safety class Clas...

Страница 15: ...Bending radius cable fixed at least 5 x cable diameter Bending radius cable moved at least 10 x cable diameter Bending cycles at least 4 million Robot suitable no Connector Parameter Characteristic Co...

Страница 16: ...ower consumption at UO 24 V DC 4 6 W 1 Input voltage OFF 0 V 2 7 V Input current OFF 0 mA 2 mA Input voltage ON 3 7 V 30 V Input current ON 5 mA 10 mA Switch input ON OFF Input delay tD 150 s 1 The no...

Страница 17: ...ak 464 nm Dominant Wavelength dom 463 nm 470 nm 476 nm Spectral bandwidth 25 nm Continuous operation switchable Radiance 35 W m sr Spectral Emission Relative spectral emission Wavelength nm 0 20 40 60...

Страница 18: ...original packaging For accessories connected devices and components observe the specific information in the associated instructions for use Ambient Conditions Operation Storage Transport Temperature...

Страница 19: ...connector 3 22 5 15 5 on both sides 14 150 13 5 31 35 30 120 19 142 light emitting surface 20 7 5 30 18 5 30 18 5 45 8 x M3 depth 5 5 A 18 5 30 30 18 5 22 3 45 4 x M3 depth 4 5 on both sides Image 4...

Страница 20: ...together with the device out of the carton 2 Fold out the tucked in sides on the bottom of the cardboard Loosening the film and forming an insertion pocket 3 Remove the device out of the insertion po...

Страница 21: ...d de energised state To mount the device tapped holes are located at the sides 3 1 2 1 8 x M3 tapped hole at the bottom Maximum screw in depth 5 5 mm 2 4 x M3 tapped hole at both long sides Maximum sc...

Страница 22: ...may only be performed in the off and de energised state NOTICE Cable damage Comply with the specified minimum bending radius Cables must generally be mounted with a strain relief clamp Use cables cor...

Страница 23: ...o the pin assignment Pin assignment 1 3 2 4 Image 5 M8 male plug 4 pin Connection diagram V GND 1 3 4 BU BK BN ON OFF Pin Core colour Signal Description 1 BN brown V Operating voltage 2 WH white NC Do...

Страница 24: ...are flashing lights or stroboscopes CAUTION Impairment of eye sight due to dazzling Do not look during operation directly in LED lighting or whose rays Wear protective goggles In the event of dazzlin...

Страница 25: ...nuous operation The lighting is switched on by setting the ON OFF signal after the delay time td Resetting the ON OFF signal turns off the lighting Continuous operation switchable The switchable conti...

Страница 26: ...ts t Lighting t Switching signal td td tON ts Continuous operation Continuous operation td td tON switchable ts Exposure time of the camera tON Power on time td Delay time Min Nom Max Delay time td 1...

Страница 27: ...utside with a damp cloth Remove excessive dirt with an approved anodised aluminium cleaner Refer to the instructions of the cleaner The connectors must be clean and dry before the device is connected...

Страница 28: ...glad to be of service Monday to Thursday 8 00 to 17 00 and Friday 8 00 to 15 00 Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Phone 49 0 3681 7974 0 www vision control com Defective devi...

Страница 29: ...separately and sent to environmentally compatible recycling Disposal including that of individual components must also always be in a way that does not harm the environment which means it must be don...

Страница 30: ...strial environments DIN EN 61000 6 4 2011 09 Electromagnetic compatibility EMC Emission standard for industrial environments DIN EN 61000 4 2 2009 12 Electromagnetic compatibility EMC Testing and meas...

Страница 31: ...LDLF30x120 B470 24V a Vision Control GmbH 2019 999 995 600 10 en 1 0 31...

Страница 32: ...Vision Control GmbH Mittelbergstra e 16 98527 Suhl Germany Telephone 49 0 3681 7974 0 Telefax 49 0 3681 7974 33 Vision Control GmbH...

Отзывы: