background image

02   - English -

2. WARNINGS

Read these instructions carefully before using the thermometer

2.1 Precautions

To avoid reading anomalies, use VisioFocus PRO according to this user manual. 

Use VisioFocus PRO in a draft-free room, at a steady temperature between 16 and 

40°C (60.8 and 104°F).

If the thermometer was stored in another room (or even in a drawer, etc.), before 

using it, run the manual calibration procedure (MQCS – par. #8). No matter if it is 

set in “NURS” or “DOCT”. 

Do not take a temperature reading in the following situations:

• if the subject is sitting in a draft or has come from another room that was ventilated 

or at a different temperature than the room where the thermometer is used;

• if, in the minutes before reading, the subject has:

- been walking, running or exercising;

- been wearing a cap, hat or scarf;

- been cool sponged on the forehead;

-  been  exposed  to  agents  that  could  alter  forehead  temperature,  e.g.  shower, 

shampoo, hair-drier, direct sunlight, fireplace heat, cold compresses therapies, air 

conditioner flow etc.; even touching the forehead can alter the temperature.

In all the above cases, interrupt the exposition of the subject to these agents and wait 

a few minutes for the forehead temperature to stabilize.

Changing  the  reading  point  will  lead  to  different  results.  Therefore,  remember, 

always 

aim the projection on the same spot, precisely at the center of the 

forehead

 (midway between the top of the nose and the hairline) and keep the 

thermometer perpendicular to the forehead. Do not take measurements on areas 

other than the centre of the forehead, except for the case at #4.2.

The temperature reading is taken in the area where the temperature is projected. 

Make certain that a 1 cm (0,4 in) area is free all the way around the temperature 

projection area: it is of major importance to make sure that this area does not include 

eyebrows, hair or clothing. If necessary, brush away any hair from the forehead but 

remember, this must be done a couple of minutes beforehand or the temperature 

reading will be higher than the actual body temperature.

When taking a temperature reading, please note that in the presence of oils, make-up 

or an oxygen mask, and in the case of elderly, the temperature detected may be 

lower than the actual body temperature.

The forehead temperature reading can be affected by profuse sweating, superficial 

wounds or head injuries.

Do not use the thermometer on a sweaty forehead

, since the temperature 

reading will be unreliable.

In the cases at #7, #8, #9, take the temperature reading on the alternative area 

(read the par. #4.2.).

The  gilt  waveguide  (figure  1)  is  the  most  delicate  part  of  the  thermometer.  It  is 

composed of a gold-plated concave mirror that must be kept clean, crystal clear and 

intact. Any damage, dust or dirt will alter the temperature reading.

!

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

Содержание 06480

Страница 1: ...mometer Mode d Emploi Lire attentivement les instructions avant d utiliser le thermom tre Seguire le istruzioni per l uso Follow instructions for use Suivre les instructions d utilisation Riferirsi al...

Страница 2: ...ttery door 4 x AAA with brief instructions Slide to open Special lanyard with additional brief instructions to be worn around the neck Faisceau lumineux de positionnement Orifice avant Capteur au fond...

Страница 3: ...ry to wait the end of the countdown without touching the device Alternatively at any time it is possible to do the manual MQCS suggested procedure In DOCT mode the HOME and the Mem buttons are enabled...

Страница 4: ...e projection on the same spot precisely at the center of the forehead midway between the top of the nose and the hairline and keep the thermometer perpendicular to the forehead Do not take measurement...

Страница 5: ...e mentioned precautions par 2 1 may lead to very low or very high temperature readings which cannot be attributed to product s malfunctions The aiming lights meet the photo biological safety requireme...

Страница 6: ...l temperature varies according to the measurement s site and throughout the day also in response to physical or mental effort for example a baby s crying Moreover the body temperature can be affected...

Страница 7: ...the HOME button release the button lights will flash twice s l o w l y and then the display will show the acquired temperature VisioFocus PRO is now ready to take a measurement For more details about...

Страница 8: ...econds it reverts to stand by mode and will display the room temperature for 45 minutes DOCT mode or 30 minutes NURS mode before shutting off 4 2 In case of sweating oxygen mask elderly patients take...

Страница 9: ...any other problem which may cause an alteration of the surface skin temperature Of course VisioFocus PRO can be used on open wounds or organs during surgical interventions ensuring maximum hygiene th...

Страница 10: ...your thermometer leaves the factory Celsius or Fahrenheit degrees referred to oral rectal or axillary or internal temperature readings or only internal temperature readings no symbol will be shown NUR...

Страница 11: ...h air conditioning in the room when appears wait for and release the button the display will show alternately the word and the temperature value otherwise choose 8 ROOM TEMPERATURE CALIBRATION 8 1 MQC...

Страница 12: ...e MQCS can also be performed in case of countdown see par 8 2 In NURS setting the MQCS is mandatory every 30 minutes In DOCT setting see the par 8 2 8 2 AQCS countdown only DOCT MODE In DOCT setting i...

Страница 13: ...he thermometer has not stabilized SOLUTION wait until the AQCS countdown has run its course without touching the thermometer or perform an MQCS par 8 DESCRIPTION while in stand by mode the room temper...

Страница 14: ...ressed the FACE button make certain the waveguide is not soiled or damaged and that the subject has not come from a cold room If you ve pressed the HOME button the temperature reading cannot be taken...

Страница 15: ...king a temperature reading or run a manual quick calibration MQCS par 8 Remove the batteries if you do not expect to use the thermometer for a long time 12 CLEANING CLEANING THE WAVEGUIDE the thermome...

Страница 16: ...the operating range are not guaranteed and the message Hi 4 and the temperature value are displayed alternately Power supply 4 AAA LR03 alkaline batteries 1 5 V included Life of high quality batteries...

Страница 17: ...metro perpendicolare al centro della fronte Correct distance and thermometer perpendicular to the forehead Bonne distance et thermom tre perpendiculaire au milieu du front Fig 3 Fig 6 Distanza corrett...

Отзывы: