background image

                                                       VP-600 

                                                             

                                                                            11A 

  6.2 Rear View   

 

 

 

 

1. DMX IN 

DMX Input RJ45 or 3 pin XLR socket 

2. DMX OUT 

DMX Output RJ45 or 3 pin XLR socket 

3. FUSE T6.3A

 

For protecting the unit when the transient current is too big.

4. POWER 

 

Power cable for AC input. 

5. LED 

DC power & signal output for linking LED fixtures. 

 

 

7. DMX Controller   

Using universal DMX controller to control the units, you have to set DMX 

address from 1 to 512 channel so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

Address

 is showing on the display. 

Pressing 

ENTER

 button and the display will blink. Use 

DOWN

 and 

UP

 

button to change the DMX512 address. Once the address has been 

selected, press and keep 

ENTER

 button pressed up to when the display   

 

 

                                                       VP-600 

                                                             

                                                                            8A 

Edit Chase

 (only chase number 6~8 are editable) 

Press the 

MENU

 button up to when the 

Edit Chase

 is showing on the 

display. Press 

ENTER

 button and 

1

 will blink, use 

UP/DOWN

 button to 

choose group 1, 2 or 3, press ENTER button to setup and use 

UP/DOWN

 to 

set 

Num

-number (06-08), 

Leng

-length (01-42, the steps, you choose from 

the total amount of steps, you want to run, for example, if the total amount of 

steps you set is 42, you can choose only first 1-10 steps to run) and 

Value

 

(to set 

step

P

-A (output all) or 1-10, 

C

-Color, 

W

-White, 

D

-Dimmer), press 

ENTER

 button to setup. Back to the main functions without any change 

please press the

 MENU 

button. 

 

Manual Test 

Press the 

MENU

 button up to when the 

Manual Test

 is showing on the 

display. Press 

ENTER

 button and 

1

 will blink, use 

UP/DOWN

 button to 

choose 

P

-A (output all) or 1-10, press 

ENTER

 button to store, use 

DOWN/UP

 to set 

D

-Dimmer, 

S

-Strobe, 

R

-Red, 

G

-Green, 

B

-Blue, 

W

-White, 

press 

ENTER

 button to setup. Back to the main functions without any 

change please press the

 MENU 

button. 

 

White Balance 

Press the 

MENU

 button up to when the 

White Balance

 is showing on the 

display. Press 

ENTER

 button and 

1

 will blink, use 

UP/DOWN

 button to 

choose 

P

-A (output all) or 1-10, press 

ENTER

 button to store, use 

DOWN/UP

 to set 

R

-Red, 

G

-Green, 

B

-Blue, press 

ENTER

 button to setup. 

Back to the main functions without any change please press the

 MENU 

button. 

 

Auto Test 

Press the 

MENU

 button up to when the 

Auto Test

 is showing on the display. 

Press 

ENTER

 button 

Testing

 will blink on the display and the unit will run 

self-test by built-in program. To go back to the main functions please press the

 

MENU

 button. 

 

 

Содержание VP-600

Страница 1: ...ctromagnetic Compatibility EMC Directive 89 336 EEC EN55014 2 1997 A1 2001 EN61000 4 2 1995 EN61000 4 3 2002 EN61000 4 4 1995 EN61000 4 5 1995 EN61000 4 6 1996 EN61000 4 11 1994 Harmonized Standard EN...

Страница 2: ...Connection 9 2 RJ45 Connection VP 600 18A 9 2 RJ45 Connection DMX Input Output LED module Input RJ45 Connector RJ45 Connector Front view of the Connector Front view of the Connector Pin 1 Not connecte...

Страница 3: ...5 pin XLR 3 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal 5 pin XLR Pin 1 GND Pin 2 Negative signal Pin 3 Positive signal Pin 4 Pin 5 not used VP 600 2A 1 Safety Introductions Please...

Страница 4: ...from the chases in one week and different time period per day y User can run the chase manually step by step by pressing the manual button y Excellent fade effect and auto running function y LCD disp...

Страница 5: ...n a non flammable flat surface in any orientation and fixed by screws There are six mounting holes on the housing Ensure that installation place is enough ventilated V Power could control the LED fixt...

Страница 6: ...e chase built in or you have programmed Enter chase group the LED on then press the chase group button again to choose the chase Once the chase has been selected press Manual button into manual mode t...

Страница 7: ...VP 600 13A 8 DMX512 Configuration 43 Channels VP 600 6A The main functions are shown below...

Страница 8: ...Friday will blink Use DOWN and UP button to select Monday or Tues or Sunday Press the ENTER button to setup hour and 14 will blink use DOWN and UP button to select hour press the ENTER button to setu...

Страница 9: ...want to run for example if the total amount of steps you set is 42 you can choose only first 1 10 steps to run and Value to set step P A output all or 1 10 C Color W White D Dimmer press ENTER button...

Страница 10: ...Master Mode 3 SLAVE On Slave Mode LED 4 POWER On Power on 5 Menu Press the button to select the programming functions 6 Up Press the button to go forward for the desired functions 7 Enter Press the bu...