background image

 
                                                                                     

 

10- 

  Fixture Hours

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 button 

and the display will show the number of working hours of the unit. To go back to the functions press the

 

MENU

 button. 

 
 

  Software version

 

Press the 

MENU

 button up to when the 

  is blinking on the display. Pressing 

ENTER

 button 

and the display will show the version of software of the unit. To go back to the functions press the

 MENU

 

button again. 

 
 
 

4.

 How TO Control The Unit

  

You can operate the unit in two ways

 

 1. 

By master/slave built-in preprogram function   

2. 

By DMX controller

 

No need to turn the unit off when you change the DMX address, as new DMX address setting will be 

effected at once. Every time you turn the unit on, it will show 

  on the display and move all the 

motors to their ‘home’ position. After that the unit will be ready to receive DMX signal or run the built in 

programs. 

 

4.1 

Master/Slave Built In Preprogrammed Function

  

By linking the units in master/slave connection, the first unit will control the other units to give an 

automatic, sound activated, synchronized light show. This function is good when you want an instant 

show. You have to select 

  (show 1) or 

  (show 2) ……or 

  (show 19, show17~19 have 

to be edited by the user) show for the first unit. Its DMX input jack will have nothing plugged into. The 

other units will be slave mode automatic.

  

 

4.2 

DMX Controller

  

 

Use universal DMX controller to control the units, you have to set DMX address from 1 to 512 channel 

so that the units can receive DMX signal. 

Press the 

MENU

 button up to when the 

  is showing on the display. Pressing 

ENTER

 button and 

the display will blink. Use 

DOWN

 and 

UP

 button to change the DMX512 address. Once the address has 

been selected, press and keep 

ENTER

 button pressed up to when the display stops blinking or storing 

automatically 8 seconds later. To go back to the functions without any change press the

 MENU

 button 

again.   

 

 

 

UnRegister

ed

Содержание BW-54-3RGBW IV

Страница 1: ...BW 54 3RGBW User Manual Please read the instructions carefully before use U n R e g i s t e r e d...

Страница 2: ...Set The Fixture 4 3 1 Control Panel 4 3 2 Main Functions 4 4 How To Control The Unit 10 4 1 Master Slave Built In Preprogram Function 10 4 2 DMX Controler 10 4 3 DMX 512 Configuration 11 4 4 DMX512 Co...

Страница 3: ...here the temperature is higher than this Don t connect the device to any dimmer pack First run there will be smoke or smells and all disappearing a few minutes later Make sure there are no flammable m...

Страница 4: ...holes on the bracket Always ensure that the unit is firmly fixed to avoid vibration and slipping while operating Always ensure that the structure to which you are attaching the unit is secure and is a...

Страница 5: ...rward in the selected functions 7 ENTER To confirm the selected functions 3 2 Main Functions To select any functions press MENU button until the required one is shown on the display Select the functio...

Страница 6: ...mode for 5 minutes without any change or restarting the unit the key board become locked Press ENTER button to enable the menu the display will show press UP and DOWN button until it shows then press...

Страница 7: ...on and the display will blink Use DOWN and UP button to change the DMX 512 address Once the address has been selected press ENTER button to setup or automatically exit menu mode without any change aft...

Страница 8: ...d UP button to select Flash mode Red Green Blue White Yellow Purple Cyan Whole Rotation or fade press ENTER button to confirm then use DOWN and UP button to adjust the dimmer 1 9 Notice 1 If flash mod...

Страница 9: ...without any change press the MENU button Blackout mode Press the MENU button up to when the is showing on the display Pressing ENTER button and select the mode Pressing ENTER button and the display wi...

Страница 10: ...isplay Pressing ENTER button and the display will blink Use DOWN and UP button to select the lock the key board normal Once select press the ENTER button to setup or automatically return to the main f...

Страница 11: ...he built in programs 4 1 Master Slave Built In Preprogrammed Function By linking the units in master slave connection the first unit will control the other units to give an automatic sound activated s...

Страница 12: ...11 Please refer to the following diagram to address your DMX512 channel for the first 4 units 4 Channels 5 Channels 7 Channels 4 3 DMX 512 Configuration U n R e g i s t e r e d...

Страница 13: ...t connectors are pass through to maintain the DMX circuit when one of the units power is disconnected 5 Each lighting unit needs to have an address set to receive the data sent by the controller The a...

Страница 14: ...ar or run alongside to high voltage cables that may cause damage or interference to DMX interface circuit 6 Fixture Cleaning The cleaning of internal must be carried out periodically to optimize light...

Страница 15: ...14 U n R e g i s t e r e d...

Страница 16: ...15 Innovation Quality Performance U n R e g i s t e r e d...

Отзывы: