7 A
D60 Lumens: 1465.72lm Efficacy: 27.92lm/W
8
A
4. How To Control The Fixture
Please access the fixture in three ways
:
1. By master/slave built-in preprogram function
2. By DMX controller
3. By VD-T
4.1 Master/Slave Built In Preprogrammed Function
By linking the fixtures in master/slave connection, the first fixture will control the other
fixtures to give an automatic, sound activated, synchronized light show. This function is
good when you want an instant show
4.2
DMX Controller
Use universal DMX controller to control the fixtures, you have to set DMX address from 1
to 512 channel so that the units can receive DMX signal.
Press the
MENU
button up to until Address is shown on the display. Pressing
ENTER
button and the display will blink. Use
DOWN
and
UP
button to change the DMX512
address. Once the address has been selected, press and keep
ENTER
button pressed up
to when the display stops blinking or storing automatically 8 seconds later. To go back to
the functions without any change press the
MENU
button again.
Please refer to the following diagram to address your DMX512 channel for the first 4
fixtures
:
Channel Mode
Fixture 1
Address
Fixture 2
Address
Fixture 3
Address
Fixture 4
Address
4
channels
1 5 9 13
4D channels
1
6
11
16
4C channels
1
8
15
22