3 A
Never turn on and off the fixture time after time.
The housing, the lenses, or the ultraviolet filter must be replaced if they are visibly
damaged.
Do not open the fixture as there are no user serviceable parts inside. Never try to repair
the fixture by yourself. Repairs carried out by unskilled people can lead to damage or
malfunction. Please contact the nearest authorized technical assistance center.
Disconnect the mains power if the fixture is not used for a long time.
Do use original packing materials once transport it again.
To prevent or reduce the risk of electrical shock or fire, do not expose the fixture to rain
or moisture.
Do not look directly at the LED light beam while the fixture is on.
Installation
The fixture should be mounted via its screw holes on the bracket. Always ensure that
the fixture is firmly fixed to avoid vibration and slipping while operating. Always ensure
that the structure to which you are attaching the fixture is secure and is able to support a
weight of 10 times of the fixture’s weight. Also always use a safety cable that can hold 12
times of the weight of the fixture when installing the fixture.
The equipment must be fixed by professionals. And it must be fixed at a place where is
out of the touch of people and has no one pass by or under it.
2. Techical Specfications
Light Source
:
3W LED x 54pcs
Voltage
:
AC110-230V 50/60Hz
Power Consumption
:
58W
Beam Angle:
10° 25° 40° 60°
Dimension
:
353.0x262.0x64.0mm
Weight
:
4.2Kgs
12
A
4.5 DMX512 Connection
1. If you using a controller with 5 pins DMX output, you need to use a 3 to 5 pin
adapter-cable.
2. At last fixture, the DMX cable has to be terminated with a terminator. Solder a 120 ohm
1/4W resistor between pin 2(DMX-) and pin 3(DMX+) into a 3-pin XLR-plug and plug it
in the DMX-output of the last fixture.
3. Connect the fixture together in a `daisy chain` by XLR plug from the output of the fixture
to the input of the next fixture.The cable can not branched or split to a `Y` cable. DMX
512 is a very high-speed signal. Inadequate or damaged cables, soldered joints or
corroded connectors can easily distort the signal and shut down the system.
4. The DMX output and input connectors are pass-through to maintain the DMX circuit,
when one of the units’ power is disconnected.
5. Each lighting fixture needs to have an address set to receive the data sent by the
controller. The address number is between 0-511 (usually 0 & 1 are equal to 1).
6. The end of the DMX 512 system should be terminated to reduce signal errors.
7. 3 pin XLR connectors are more popular than 5 pin XLR.
3 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+)
5 pin XLR: Pin 1: GND, Pin 2: Negative signal (-), Pin 3: Positive signal (+), Pin 4/Pin 5:
Not used.