LABEL

Standard bar code labels for finished goods

The standard bar code labels are product labels and used 
for identification of goods. The finished goods are packed in 
final packing area. The standard packing units are labeled 

with standard bar code labels before transported as finished 
goods to warehouses. The labels are on each packing unit 
and contain Vishay Semiconductor GmbH specific data.

DRY PACKING

The reel is packed in an anti-humidity bag to protect the 
devices from absorbing moisture during transportation and 
storage.

FINAL PACKING

The sealed reel is packed into a cardboard box. A secondary 
cardboard box is used for shipping purposes.

 

 

 

RECOMMENDED METHOD OF STORAGE

Dry box storage is recommended as soon as the aluminum 
bag has been opened to prevent moisture absorption. The 
following conditions should be observed, if dry boxes are 
not available:

• Storage temperature 10 °C to 30 °C

• Storage humidity 

 60 % RH max.

After more than 168 h under these conditions moisture 
content will be too high for reflow soldering.

In case of moisture absorption, the devices will recover to 
the former condition by drying under the following condition:

192 h at 40 °C + 5 °C / - 0 °C and < 5 % RH (dry air/nitrogen) 
or 

 

96 h at 60 °C + 5 °C and < 5 % RH for all device containers 
or 

 

24 h at 125 °C + 5 °C not suitable for reel or tubes.

An EIA JEDEC

®

 standard J-STD-020 level 3 label is included 

on all dry bags.

VISHAY SEMICONDUCTOR GmbH STANDARD BAR CODE PRODUCT LABEL

 (Finished goods)

PLAIN WRITING

ABBREVIATION

LENGTH

Item-description

-

18

Item-n

u

m

b

er

INO

8

Selection-code

SEL

3

LOT-/serial-n

u

m

b

er

BATCH

10

Data-code

COD

3 (YWW)

Plant-code

PTC

2

Q

u

antity

QTY

8

Accepted 

b

y

ACC

-

Packed 

b

y

PCK

-

Mixed code indicator

MIXED CODE

-

Origin

Company logo

Long bar code top

Type

Length

Item-n

u

m

b

er

N

8

Plant-code

N

2

Se

qu

ence-n

u

m

b

er

X

3

Q

u

antity

N

8

Total length

-

21

Short bar code bottom

Type

Length

Selection-code

X

3

Data-code

N

3

Batch-n

u

m

b

er

X

10

Filter

-

1

Total length

-

17

Aluminum bag

Label

Reel

15973

Содержание TSOP573 Series

Страница 1: ...eiver modules for infrared remote control systems A PIN diode and a preamplifier are assembled on a lead frame the epoxy lens cap is designed as an IR filter The demodulated output signal can be directly connected to a microprocessor for decoding The TSOP573 is optimized to better suppress spurious pulses from energy saving lamps The TSOP575 has an excellent noise suppression It is immune to dimme...

Страница 2: ...mponents R1 and C1 are optional to improve the robustness against electrical overstress typical values are R1 100 Ω C1 0 1 µF ABSOLUTE MAXIMUM RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT Supply voltage VS 0 3 to 6 V Supply current IS 5 mA Output voltage VO 0 3 to VS 0 3 V Output current IO 5 mA Junction temperature Tj 100 C Storage temperature range Tstg 25 to 85 C Operating temperature ran...

Страница 3: ...0 tpo tpi 6 f0 tpi 6 f0 is recommended for optimal function 0 0 1 0 2 0 3 0 4 0 5 0 1 10 1000 100 000 t po Output Pulse Width ms Ee Irradiance mW m2 Output pulse width Input burst length λ 950 nm optical test signal Fig 1 Ee t VO VOH VOL t 600 µs 600 µs t 60 ms ton toff 94 8134 Optical Test Signal Output Signal see fig 4 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 1 1 10 100 1000 10 000 t on t off Output ...

Страница 4: ... 5 0 6 0 7 0 8 0 9 1 0 1 10 100 1000 ΔVsRMS AC Voltage on DC Supply Voltage mV E e min Threshold Irradiance mW m 2 f f0 f 20 kHz f 30 kHz f 100 Hz f 10 kHz 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 9 0 20 40 60 80 100 120 Burst Length number of cycles burst Max Envelope Duty Cycle TSOP573 TSOP575 140 0 8 Tamb Ambient Temperature C E e min Sensitivity mW m 2 0 0 05 0 10 0 15 0 20 0 40 30 10 10 30 50 70 90 0 ...

Страница 5: ...weakly modulated patterns from fluorescent lamps with electronic ballasts see figure 12 or figure 13 Fig 13 IR Signal from Fluorescent Lamp with Low Modulation Fig 14 IR Signal from Fluorescent Lamp with High Modulation Notes For data formats with long bursts more than 10 carrier cycles please see the datasheet for TSOP572 TSOP574 Best choice of AGC for some popular IR codes TSOP57336 MCIR RCMM TS...

Страница 6: ...GND Out Vs Vs GND GND GND 0 75 0 05 4 x 0 75 3 0 35 0 05 8 x 1 5 3 0 3 0 3 0 3 0 7 1 9 3 4 Not indicated tolerances 0 1 specifications according to DIN technical drawings All dimensions in mm Drawing No 6 550 5315 01 4 Issue 2 12 02 14 marking area Drawing refers to following types TSOP37 TSOP57 Proposed pad layout from component side dim for reference only 3 95 3 95 0 35 0 8 2 75 3 4 x 4x 1 2 3 4...

Страница 7: ...re at the device surface Since there is a temperature difference between the component and the circuit board it should be verified that the temperature of the device is accurately being measured Handling after reflow should be done only after the work surface has been cooled off Manual Soldering Use a soldering iron of 25 W or less Adjust the temperature of the soldering iron below 300 C Finish so...

Страница 8: ...eters Leader and trailer tape Parts mounted Empty trailer 200 mm min Empty leader 400 mm min Direction of pulling out Unreel direction Ø 60 min Ø Y 2 0 5 Label posted here coming out from reel Tape position 12 4 18 4 max Ø 13 0 2 Ø 21 0 8 100 mm min with cover tape X 2 1 Tape and reel dimensions 2 1 75 5 5 12 0 3 8 4 Ø 1 5 0 3 Reel size Y TT1 Ø 180 2 1800 pcs TT2 Ø 330 2 7000 pcs 1 2 Technical dra...

Страница 9: ...een opened to prevent moisture absorption The following conditions should be observed if dry boxes are not available Storage temperature 10 C to 30 C Storage humidity 60 RH max After more than 168 h under these conditions moisture content will be too high for reflow soldering In case of moisture absorption the devices will recover to the former condition by drying under the following condition 192...

Страница 10: ...specific data BAR CODE PRODUCT LABEL Example 1 Calculated shelf life in sealed bag 12 months at 40 C and 90 relative humidity RH 3 After bag is opened devices that will be subjected to reflow solder or other high temperature process must be 4 Devices require bake before mounting if a Humidity Indicator Card reads 10 for level 2a 5a devices or 60 for level 2 devices when read at 23 5 C b 3a or 3b a...

Страница 11: ...mer application by the customer s technical experts Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase including but not limited to the warranty expressed therein Except as expressly indicated in writing Vishay products are not designed for use in medical life saving or life sustaining applications or for any other application in which the failure of...

Отзывы: