Vishay TSOP573 Series Скачать руководство пользователя страница 4

TSOP573.., TSOP575..

www.vishay.com

Vishay Semiconductors

 

 

Rev. 1.4, 25-Feb-14

4

Document Number: 82450

THIS DOCUMENT IS SUBJECT TO CHANGE WITHOUT NOTICE. THE PRODUCTS DESCRIBED HEREIN AND THIS DOCUMENT

ARE SUBJECT TO SPECIFIC DISCLAIMERS, SET FORTH AT 

www.vishay.com/doc?91000

 Fig. 7 - Sensitivity vs. Supply Voltage Disturbances

 Fig. 8 - Max. Envelope Duty Cycle vs. Burst Length

 Fig. 9 - Sensitivity vs. Ambient Temperature

 Fig. 10 - Relative Spectral Sensitivity vs. Wavelength

 Fig. 11 - Horizontal Directivity

 Fig. 12 - Sensitivity vs. Supply Voltage

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

1

10

100

1000

Δ

Vs

RMS

 - AC Voltage on DC Supply Voltage (mV)

E

e min.

 - Threshold Irradiance (mW/m

2

)

f = f

0

f = 20 kHz

f = 30 kHz

f = 100 Hz

f = 10 kHz

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.9

0

20

40

60

80

100

120

Burst Length (number of cycles/burst)

Max. Envelope Duty Cycle

TSOP573..

TSOP575..

140

0.8

T

amb

 - Ambient Temperature (°C)

E

e min.

 - Sensitivity (mW/m

2

)

0

0.05

0.10

0.15

0.20

0.40

-30

-10

10

30

50

70

90

0.30

0.25

0.35

0

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1.0

750 800 850 900 950 1000 1050

1150

λ

 - Wavelength (nm)

S(

λ

)

rel

 - Relative Spectral Sensitivity

1100

0.1

0.3

0.5

0.7

0.9

80°

70°

60°

50°

40°

30°

20°

10°

-10°

-20°

-30°

-40°

-50°

-60°

-70°

-80°

21947

0

0.1

0.2

0.3

0.4

0.5

0.8

1.5

2.5

3.5

4.5

5.5

2.0

3.0

4.0

5.0

V

S

 - Supply Voltage (V)

E

e min.

 - Sensitivity (mW/m

2

)

0.6

0.7

Содержание TSOP573 Series

Страница 1: ...eiver modules for infrared remote control systems A PIN diode and a preamplifier are assembled on a lead frame the epoxy lens cap is designed as an IR filter The demodulated output signal can be directly connected to a microprocessor for decoding The TSOP573 is optimized to better suppress spurious pulses from energy saving lamps The TSOP575 has an excellent noise suppression It is immune to dimme...

Страница 2: ...mponents R1 and C1 are optional to improve the robustness against electrical overstress typical values are R1 100 Ω C1 0 1 µF ABSOLUTE MAXIMUM RATINGS PARAMETER TEST CONDITION SYMBOL VALUE UNIT Supply voltage VS 0 3 to 6 V Supply current IS 5 mA Output voltage VO 0 3 to VS 0 3 V Output current IO 5 mA Junction temperature Tj 100 C Storage temperature range Tstg 25 to 85 C Operating temperature ran...

Страница 3: ...0 tpo tpi 6 f0 tpi 6 f0 is recommended for optimal function 0 0 1 0 2 0 3 0 4 0 5 0 1 10 1000 100 000 t po Output Pulse Width ms Ee Irradiance mW m2 Output pulse width Input burst length λ 950 nm optical test signal Fig 1 Ee t VO VOH VOL t 600 µs 600 µs t 60 ms ton toff 94 8134 Optical Test Signal Output Signal see fig 4 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 8 0 1 1 10 100 1000 10 000 t on t off Output ...

Страница 4: ... 5 0 6 0 7 0 8 0 9 1 0 1 10 100 1000 ΔVsRMS AC Voltage on DC Supply Voltage mV E e min Threshold Irradiance mW m 2 f f0 f 20 kHz f 30 kHz f 100 Hz f 10 kHz 0 0 1 0 2 0 3 0 4 0 5 0 6 0 7 0 9 0 20 40 60 80 100 120 Burst Length number of cycles burst Max Envelope Duty Cycle TSOP573 TSOP575 140 0 8 Tamb Ambient Temperature C E e min Sensitivity mW m 2 0 0 05 0 10 0 15 0 20 0 40 30 10 10 30 50 70 90 0 ...

Страница 5: ...weakly modulated patterns from fluorescent lamps with electronic ballasts see figure 12 or figure 13 Fig 13 IR Signal from Fluorescent Lamp with Low Modulation Fig 14 IR Signal from Fluorescent Lamp with High Modulation Notes For data formats with long bursts more than 10 carrier cycles please see the datasheet for TSOP572 TSOP574 Best choice of AGC for some popular IR codes TSOP57336 MCIR RCMM TS...

Страница 6: ...GND Out Vs Vs GND GND GND 0 75 0 05 4 x 0 75 3 0 35 0 05 8 x 1 5 3 0 3 0 3 0 3 0 7 1 9 3 4 Not indicated tolerances 0 1 specifications according to DIN technical drawings All dimensions in mm Drawing No 6 550 5315 01 4 Issue 2 12 02 14 marking area Drawing refers to following types TSOP37 TSOP57 Proposed pad layout from component side dim for reference only 3 95 3 95 0 35 0 8 2 75 3 4 x 4x 1 2 3 4...

Страница 7: ...re at the device surface Since there is a temperature difference between the component and the circuit board it should be verified that the temperature of the device is accurately being measured Handling after reflow should be done only after the work surface has been cooled off Manual Soldering Use a soldering iron of 25 W or less Adjust the temperature of the soldering iron below 300 C Finish so...

Страница 8: ...eters Leader and trailer tape Parts mounted Empty trailer 200 mm min Empty leader 400 mm min Direction of pulling out Unreel direction Ø 60 min Ø Y 2 0 5 Label posted here coming out from reel Tape position 12 4 18 4 max Ø 13 0 2 Ø 21 0 8 100 mm min with cover tape X 2 1 Tape and reel dimensions 2 1 75 5 5 12 0 3 8 4 Ø 1 5 0 3 Reel size Y TT1 Ø 180 2 1800 pcs TT2 Ø 330 2 7000 pcs 1 2 Technical dra...

Страница 9: ...een opened to prevent moisture absorption The following conditions should be observed if dry boxes are not available Storage temperature 10 C to 30 C Storage humidity 60 RH max After more than 168 h under these conditions moisture content will be too high for reflow soldering In case of moisture absorption the devices will recover to the former condition by drying under the following condition 192...

Страница 10: ...specific data BAR CODE PRODUCT LABEL Example 1 Calculated shelf life in sealed bag 12 months at 40 C and 90 relative humidity RH 3 After bag is opened devices that will be subjected to reflow solder or other high temperature process must be 4 Devices require bake before mounting if a Humidity Indicator Card reads 10 for level 2a 5a devices or 60 for level 2 devices when read at 23 5 C b 3a or 3b a...

Страница 11: ...mer application by the customer s technical experts Product specifications do not expand or otherwise modify Vishay s terms and conditions of purchase including but not limited to the warranty expressed therein Except as expressly indicated in writing Vishay products are not designed for use in medical life saving or life sustaining applications or for any other application in which the failure of...

Отзывы: