background image

plug’n’dose TP

operating and maintenance instructions

10 / 11

 Version 1.3

Copyright ©

8

Disposal  

9

EC-Declaration of Conformity  

n accordance with the EC-Machinery Directive 2006/42/EG, Appendix II A

We, 

hereby declare that the machinery described below complies in its design and
construction and in the version marketed by us with the basic safety and health
requirements of the EC Directive 2006/42/EG.

Dispose of the control unit in an environmentally safe way. All materials and 

products left in containers must be treated in accordance with the appropriate 

recycling requirements.
Electrical components must not be disposed of together with household waste. 

They must be taken to the collection points provided for this purpose.
2002/96/EC (WEEE) EC Directive on waste electrical and electronic equipment.
This unit complies with RoHS requirements.

ViscoTec Pumpen- und Dosiertechnik GmbH
Amperstraße 13
D-84513 Töging          

Product description
Function

Dosing system with dispenser

Model

plug´n´dose TP  with dispenser

eco-PEN300 / 450 / 600 / 700

Harmonised standards applied
DIN EN ISO 12100:2011-03

Safety of machinery

DIN EN 809:2011-01

Pumps and Pump Units for Liquids (Common safety 

requirements)

DIN EN ISO 13857:2008-06

Safety of machinery - Safety distances

DIN EN 61000-6-3:2011-09

Electromagnetic compatibility

DIN EN 61000-6-2:2011-06

Electromagnetic compatibility, Immunity

Töging, 12.01.2012

Georg Senftl

Managing Director and Person authorised to collect the technical

documents (address see above)

Содержание PreeFlow plug'n'dose TP

Страница 1: ...Dosing system Speed Control plug n dose TP operating and maintenance instructions Translation of the German original operating manual ...

Страница 2: ...Printed 20 1 12 ...

Страница 3: ... Correct use warranty 5 4 4 Qualifications of the operators and maintenance personnel 5 4 5 Organisational measures 6 4 6 Preparing to operate visual inspection 6 4 7 Preventing damage to the dispenser motor 6 5 Operation 7 5 1 Displays and controls connections 7 5 2 Starting up 8 5 3 Shutting down 8 5 4 Operation 9 6 Troubleshooting Maintenance 9 7 Specifications 9 8 Disposal 10 9 EC Declaration ...

Страница 4: ...ntrol and a dispenser It has been developed and tested for precision operation with our dispensers We would appreciate your assistance in our efforts to maintain the highest possible quality standards Please send us any suggestions you may have on ways that we may further improve our products 2 Function description The plug n dose TP control unit controls the dispenser by converting the output sig...

Страница 5: ...xpress written consent of the manufacturer will render the warranty void and result in the loss of any right to make a claim under the warranty No liability can be accepted for damage caused by failure to observe the operating and maintenance instructions 4 4 Qualifications of the operators and maintenance personnel The operating organisation is responsible for ensuring that the operators and main...

Страница 6: ...uctions for the dispenser s that are connected to the control unit must be complied with 4 6 Preparing to operate visual inspection The control unit must be visually examined each day before the start of work and before all shift changes If there is any doubt as to the system s readiness for operation it must be shut down immediately and inspected by a specialist before operation resumes 4 7 Preve...

Страница 7: ...perated the safety information in Chapter 4 Safety beginning on page 5 must have been read and understood Item Function description A LED Displays the operating modes ON ready for operation OFF dosing suck back in operation Flashing fault 2 Connector 2 Mains adapter or supply voltage 3 Connector 3 Dispenser 4 Connector 4 pressure adapter 2 4 4 3 2 A 3 A Fig 2 ...

Страница 8: ...hen the dispenser is connected Fill the dispenser with medium as directed in its operating and maintenance instructions 5 3 Shutting down The unit is shut down in reverse order of setting up Caution The dispenser lead connector 3 may only be connected and disconnected when the power supply is isolated The electronics in the drive motor could be damaged if this precaution is not taken Caution Do no...

Страница 9: ...ear at all times Do not use any aggressive solvents or detergents to clean the unit use a damp cloth only Isolate from the power supply before cleaning 7 Specifications Fault Possible cause Action control unit cannot be operated LED flashes Overcurrent shutdown Clean the dispenser if necessary replace stator See the operating instructions for the dispenser Faulty motor Dimensions h x w x d 142 x 8...

Страница 10: ...sehold waste They must be taken to the collection points provided for this purpose 2002 96 EC WEEE EC Directive on waste electrical and electronic equipment This unit complies with RoHS requirements ViscoTec Pumpen und Dosiertechnik GmbH Amperstraße 13 D 84513Töging Product description Function Dosing system with dispenser Model plug n dose TP with dispenser eco PEN300 450 600 700 Harmonised stand...

Страница 11: ...plug n dose TP operating and maintenance instructions Copyright Version 1 3 11 11 Notizen letzteSeite ...

Страница 12: ......

Отзывы: