Spraying System eco-CONTROL SC1200
Commissioning and maintenance manual
Copyright
©
11 / 16
10. Electrical Connections
10.1 Footswitch:
pins:
connections between Pin 1 + 3 starts dispensing
10.2 I/O-Port:
type:
15-pol. SubD female 2-doublerow
pins:
see
following
chart
Pin no.
Input / Output
Description
Comment:
1
--
Reserved
Reserved
2
--
GND
GND
3
--
24V DC
24V DC
4
Output
BUSY
Dispensing procedure active
5
--
GND
GND
6
Input
START
Starts dispensing
7
Input
PRG1
Programmselect Bit #1
8
Input
PRG3
Programmselect Bit #3
9
--
Reserved
Reserved
10
--
Reserved
Reserved
11
Output
READY
Ready Signal
12
Output
ERROR
Error Signal
13
Input
REMOTE
Remote active
14
Input
ERROR-IN
External Error input
15
Input
PRG2
Program select Bit#2
External selection of programs:
Programm no.
PRG-Selectbit #1
PRG-Selectbit #2
PRG-Selectbit #3
Manuell
0
0
0
Programm 1
1
0
0
Programm 2
0
1
0
Programm 3
1
1
0
Programm 4
0
0
1
Programm 5
1
0
1
Programm 6
0
1
1
Programm 7
1
1
1
Содержание preeflow eco-CONTROL SC1200
Страница 1: ...1 Commissioning and maintenance manual Spraying System eco CONTROL SC1200 for preeflow eco SPRAY ...
Страница 14: ...14 16 Spraying System eco CONTROL SC1200 Commissioning and maintenance manual Copyright ...
Страница 15: ...Spraying System eco CONTROL SC1200 Commissioning and maintenance manual Copyright 15 16 ...
Страница 16: ...info preeflow com www preeflow com ...