Dosing system eco-CONTROL EC200 DUO
Operating and maintenance instructions
Version 1.4
Copyright ©
8.3
Interface description
8.3.1
System plugs
Suitable system plugs from the manufacturer Wieland
Article number (Wieland)
Mains switch (2-pin)
25.345.3253.0, RM5.08
System plugs 19
25.345.4053.0, RM5.08
System plugs 15
25.345.4253.0, RM5.08
System plugs 14
25.630.1453.0, RM3.5
Compatible plug terminals: Manufacturers Phoenix-Contact and Weidmüller
System plugs (14)
Pin
Type
Area
Item
O +24V Output
+24V/100mA
for supplying the connected sensors
GND
GND
GND
IL1
Digital input
0/24V
Level sensor 1
IL2
Level sensor 2
OA1
Analogue
output
0-5V
Dosing pressure A (no pressure=0V)
OA2
Dosing pressure B (no pressure=0V)
GND
GND
GND
GND
OA3
Analogue
output
0-5V
Pot life / rinsing time (pot life expired=0V)
OHC
Collector*
max. 24V/10mA not set
OHE
Emitter*
OMC
Collector*
OME
Emitter*
GND
GND
* galvanically separated