Bit-6 is used to match the video impendance, which have to be set to on if the monitor is in the 
end of the bus, otherwise set to off.  

Bit-1 to Bit-5 are used to User Code setting.The DT596(F)/ID responds to 0~15 . 

•Up to 1000 user cards can be registered by the door station. 
•Easy management with LED status and sound hints. 
•There are two master cards, one 

MASTER CARD ADD 

card and one 

MASTER 

CARD  DELETE 

card,  When  registered  new  master  cards,  the  old  master 

cards are invalid automatically. 

•Card reading distance is from 3 to 5 cm. 
•The  master cards are necessary when you add or delete user cards. Please 

keep it well for future use.  

Introduction: 

6. ID Card Registration 

www.viscoo.eu

 

Electric Lock Connection  

Door Lock Controlled with Internal Power  

Note: 

1. Electronic lock of Power-on-to-unlock type should be used. 
2. The door lock is limited to 12V, and holding current must be less than 250mA. 
3. The door lock control is not timed from Exit Button(EB). 
4. The 

Unlock Mode 

Parameter of Monitor must be set to 0 (by default). EB* 

Door Lock Controlled with Dry Contact  

Note: 

1. The external power supply must be used according to the lock. 
2. The inside relay contact is restricted to AC or DC 24V/1A. 
3. The jumper must be taken off before connecting. 
4. Setup the 

Unlock Mode 

of Monitor for different lock types. 

• Power-on-to-unlock type: Unlock Mode=0 (by default) 
• Power-off-to-unlock type: Unlock Mode=1 

Содержание IT-OUT250

Страница 1: ... can be changed without notice to user Right to interpret and copyright of this manual are preserved Dutch office English 31 0 87 87 32897 GMT 1 E mail support credexalarmsystems eu Webpage http www credex nl IT OUT250 User Manual ...

Страница 2: ...4 System Wiring and Electric Lock Connection 06 5 DIP Switches Setting 12 6 ID Card Registration 14 7 Unlock Operations 16 8 Precaustions 17 9 Specifications 17 10 Cables Requirements 18 Please read this manual carefully before using the product and keep it well www viscoo eu www viscoo eu ...

Страница 3: ...quirements The maximum distance of the wiring is limited in the DT system Using different cables may also affect the maximum distance which the system can reach IT MPIN www viscoo eu 1 Parts and functions 2 Terminal Descriptions ...

Страница 4: ...e the proximity access is forbidden 1 If show the authorized user card the buzzer will sound of beep and the LED indicator will light up 2 If show the unauthorized user card the buzzer will sound of beep beep beep 8 Precaustions Please clean the unit with soft cotton cloth don t use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to c...

Страница 5: ... the user card to ID card window in standby mode the red blue indicator blink for 1 5s alternately During this ti me press CALL button to release the second lock Otherwise release the first lock if there isn t any operation within 1 5 seconds If 10 times unauthorized access cards are continuously attempted the release function is forbidden and the showing card operation is disabled for 60 seconds ...

Страница 6: ... eu Press the plastic cover on right left side to move away the cover insert a name paper then put the plastic cover back to the panel RF Basic Connection 4 System Wiring and Electric Lock Connection IT PS01 IT PSU24 www viscoo eu ...

Страница 7: ...er cards Please keep it well for future use Introduction 6 ID Card Registration www viscoo eu Electric Lock Connection Door Lock Controlled with Internal Power Note 1 Electronic lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor m...

Страница 8: ...monitors only to text menu series monitors please refer to the corresponding user manual www viscoo eu DIP Switches Settings of Door Station Total 4 bits on the DIP switches can be configured The switches can be modified either before or after installation 5 DIP Switches Setting There are 6 bit switches in total The DIP switches are used to configure the user code for each Monitor DIP Switches Set...

Страница 9: ...www viscoo eu Extending Connections with IT CCTV unit IT MPIN IT CCTV IT CCTV IT PS01 IT PSU24 IT MPIN www viscoo eu Multi Door Stations Connection IT MPIN IT PS01 IT PSU24 ...

Страница 10: ...www viscoo eu Basic IN OUT Wiring Mode Multi Monitors Connection IT PSU24 IT PS01 www viscoo eu With IT MPIN Wiring Mode IT PS01 IT PSU24 IT MPIN IT MPIN ...

Отзывы: