JP/LK (Lock Control Jumper): 

To select the lock type: see section 4 

• 

Doorstation Code DIP: 

Total 4 door stations can be supported, see section 5 

• 

RS485: 

Used to update the program for door station  

• 

MIC

: Adjust the volume of Microphone 

• 

SPK

: Adjust the volume of Speaker 

• 

Main Connect Port: 

To connect the bus line and the electronic locks. 

• 

BUS: 

Connect to the bus line, no polarity. 

• 

PL: 

External lock power input, connect to the power positive (power +). 

• 

S1+, S2+: 

Lock power(+) output, to connect 2 locks. 

• 

S-: 

Lock power(-) output, connect to the power(-) input of locks(only when using the 

camera  to  power  the  locks,  if  using  the  external  power  supply  for  the  locks,  the  S- 
will not be connected). 

IT-OUT250 Mounting 

3. Door Station Mounting 

www.viscoo.eu

 

• You can activate the electric door strike by pressing the request to exit button con-

nected to the unit. Pressing request to exit button 1 releases relay 1, and pressing 
request to exit button 2 releases relay 2.(The unlock function will work when the 
request to exit button is pushed, even while the proximity access is forbidden. 

1. If show the authorized user card,the buzzer will sound of beep+,and the 
LED indicator will light up. 
2. If show the unauthorized user card, the buzzer will sound of beep, beep, 
beep. 

8. Precaustions 

•  Please clean the unit with soft cotton cloth, don't use the organic impregnant or 

chemical  clean  agent.  If  necessary,  please  use  a  little  pure  water  or  dilute  soap 
water to clean the dust. 

•  The unit is weather resistant. However do not  spray high pressure water on ac-

cess  control  keypad  directly.  Excessive  moisture  may  cause  problems  with  the 
unit. 

•  You must use the right adaptor which is supplied by the manufacture or approved 

by the manufacture.. 

•  Pay attention to the high voltage inside the products, please refer service only to 

a trained and qualified professional. 

9. Specifications 

•Power Supply: DC 24V (supplied by PS4-24V or PS5-24V); 
•Power Consumption: Standby 60mA; Working status 200mA; 
•Camera: Pinhole Sharp Color CCD; 420 TV Lines; 
•Lock Power supply: 12Vdc, 300mA (Internal Power); 
•Number of relay circuits: 2 
•Mounting: surface mounting(IT-OUT250) Flush mounting (IT-OUT250-F)  
•Working temperature: -10ºC ~ +45ºC 
•Wiring: 2 wires, non-polarity 
•Dimension: 176(H)×90(W)×28(D)mm(DT596/ID)  
                        220(H)×119(W)×52(D)mm(DT596F/ID) 

Содержание IT-OUT250

Страница 1: ... can be changed without notice to user Right to interpret and copyright of this manual are preserved Dutch office English 31 0 87 87 32897 GMT 1 E mail support credexalarmsystems eu Webpage http www credex nl IT OUT250 User Manual ...

Страница 2: ...4 System Wiring and Electric Lock Connection 06 5 DIP Switches Setting 12 6 ID Card Registration 14 7 Unlock Operations 16 8 Precaustions 17 9 Specifications 17 10 Cables Requirements 18 Please read this manual carefully before using the product and keep it well www viscoo eu www viscoo eu ...

Страница 3: ...quirements The maximum distance of the wiring is limited in the DT system Using different cables may also affect the maximum distance which the system can reach IT MPIN www viscoo eu 1 Parts and functions 2 Terminal Descriptions ...

Страница 4: ...e the proximity access is forbidden 1 If show the authorized user card the buzzer will sound of beep and the LED indicator will light up 2 If show the unauthorized user card the buzzer will sound of beep beep beep 8 Precaustions Please clean the unit with soft cotton cloth don t use the organic impregnant or chemical clean agent If necessary please use a little pure water or dilute soap water to c...

Страница 5: ... the user card to ID card window in standby mode the red blue indicator blink for 1 5s alternately During this ti me press CALL button to release the second lock Otherwise release the first lock if there isn t any operation within 1 5 seconds If 10 times unauthorized access cards are continuously attempted the release function is forbidden and the showing card operation is disabled for 60 seconds ...

Страница 6: ... eu Press the plastic cover on right left side to move away the cover insert a name paper then put the plastic cover back to the panel RF Basic Connection 4 System Wiring and Electric Lock Connection IT PS01 IT PSU24 www viscoo eu ...

Страница 7: ...er cards Please keep it well for future use Introduction 6 ID Card Registration www viscoo eu Electric Lock Connection Door Lock Controlled with Internal Power Note 1 Electronic lock of Power on to unlock type should be used 2 The door lock is limited to 12V and holding current must be less than 250mA 3 The door lock control is not timed from Exit Button EB 4 The Unlock Mode Parameter of Monitor m...

Страница 8: ...monitors only to text menu series monitors please refer to the corresponding user manual www viscoo eu DIP Switches Settings of Door Station Total 4 bits on the DIP switches can be configured The switches can be modified either before or after installation 5 DIP Switches Setting There are 6 bit switches in total The DIP switches are used to configure the user code for each Monitor DIP Switches Set...

Страница 9: ...www viscoo eu Extending Connections with IT CCTV unit IT MPIN IT CCTV IT CCTV IT PS01 IT PSU24 IT MPIN www viscoo eu Multi Door Stations Connection IT MPIN IT PS01 IT PSU24 ...

Страница 10: ...www viscoo eu Basic IN OUT Wiring Mode Multi Monitors Connection IT PSU24 IT PS01 www viscoo eu With IT MPIN Wiring Mode IT PS01 IT PSU24 IT MPIN IT MPIN ...

Отзывы: