AXS-100, AXS-100XT 

Indoor Two-Door Proximity Access Control System 

Installation Guide

 

 

1. INTRODUCTION 

The AXS-100/AXS-100XT is an electronic access control system 
for controlling two doors.. Eight controllers can be networked 
together to control a total of 16 doors. The controller relay 
activates a lock or an electromagnetic strike (EMS), when a valid 
proximity key card or tag is presented to the reader. For detailed 
system description, refer to the AXS-100/AXS-100XT user’s 
guide. 
  

The use of a proximity (non-contact) key makes the installation of 
the AXS-100/AXS-100XT system an attractive possibility in harsh 
environments and in places with poor lighting conditions.  
The proximity keys are totally sealed and wear resistant. The lock 
reads the key ID, whenever the key is held close to the reader. 

 

2. SPECIFICATIONS 

 

AXS-100, AXS-100XT CONROLLER 
Power Input: 

14 - 16.5 VAC, 50VA  

Max Current Consumption: 

2.5A 

Memory Capacity:

 5,000 access card codes 

Event Log:

 1000 records per controller 

Event Printout:

 RS-232 channel to printer or PC  

System Programming: 

From controller #1. PC may be connected for 

use as supplemental monitoring only. 

Time Schedules:

 64 separate schedules. Each key may be assigned 

to 2 schedules. 

Dry Contact Relay:

 Max 1A continuous 

Doors Per Controller: 

Up to 2 

Readers Per Controller:

 Up to 2 ex 1 internal (for programming) 

Controllers Per Network: 

8

  

Inputs (x 2 doors): 

Request-to-exit, door position, 2 programmable 

inputs   

Outputs:

  2 lock relays, NO/NC dry contact, 30VDC 2A max 

 

1 auxiliary relay, NO/NC dry contact, 30V DC 2A max 
Output power for 2 locks:  10.3 - 12VDC, 400mA max 
2 readers output: 70 mA max 

Anti Passback (APB) Modes: 

1. Local to each controller 
2. Network APB

 

Indicators (LEDs):

 5 (see figure 5)

 

Operating Temperatures:

 0°C to 50°C (32°F to 122°F) 

Dimensions (LxWxD):

 

315x262x74mm (12-3/8x10-5/16x10-15/16 in) 

Weight: 

AXS-100:  3.8 kg (8.4 lb)  
AXS-100XT: 3 kg (6.6 lb) 

Color: 

 White 

Compliance with standards

: Complies with Part 15 of the FCC 

Rules and RSS-210 of Industry and Science Canada. 
 

Operation is subject to the following two conditions

: (1) This 

device may not cause harmful interference, and (2) this device must 
accept any interference received, including interference that may 
cause undesired operation. 

 

READERS 

Operating Temperatures:

 -20°C to 50°C (-4°F to 122°F)

 

Color:

 Dark brown 

Minimum distance between readers:

 60 cm (2 ft)

 

RDR-4 PROXIMITY READER 

Weight:

 121.5 g (4.3 oz) 

Indicators: 

Tricolor LED (Green, Red, Amber) 

Cable (to AXS-100/AXS-100XT control unit) maximum length:

  

22 AWG up to 60 m (200 ft) 
18 AWG up to 100 m (320 ft) 

Dimensions (LxWxD):

 

116 x 70 x 16.8 mm (4-1/2 x 2-3/4 x 5/8 in) 

RDK-4 PROXIMITY READER WITH KEYPAD

 

(optional, not evaluated by UL)

 

Weight:

 170 g (6 oz) 

Power input:

 12-16V DC from the AXS-100 / AXS-100XT 

Buttons:

 12 (numeric keypad) 

Dimensions (LxWxD)

122x82x31mm (4-13/16 x 3-1/2 x 1-1/4 in)  

 

CARDS (*)

 

CRD-1SL ISO STANDARD SLOTTED AND NUMBERED 
PROXIMITY CARD 

Card ID: 

One of a trillion different combinations

 

Dimensions (LxWxD)

85x54x1mm (3 5/16 x 2 1/8 x 1/32 in)

 

Weight

: 2.5 g (0.1 oz) 

Color

: White 

CRD-25SL

: Package of twenty-five CRD-1SL slotted proximity 

cards with print 

CRD-25: 

Package of twenty-five CRD-1 non-slotted proximity cards 

(optional). 

CRD-25S:

 Slotted proximity card 

 

TAGS (*)

 

TAG-1:

 One proximity tag 

* Both cards and tags contain 40-bit code and using 

Manchester encoding 

.

 

3. MOUNTING 

3.1 Metal Box Mounting 

The system must be installed indoors, within the protected 
premise, in accordance with the National Electrical Code 
(NFPA70) and the local authorities having jurisdiction. 

For AXS-100XT use only the supplied plug-in transformer:

 

PRI 120V/60Hz @ 0.59A, SEC 16.5VAC / 50VA 
BE116250CAA0040, Basler Electric, Class 2 NOT WET, 
 
Do not connect (the transformer) to a power receptacle that is 
controlled by a switch. 

Use the box as a template

to mark on the mounting

surface, drill 4 holes on the

mounting surface and

fasten the box to the

mounting surface by using

4 screws.

Transformer (AXS-100 only).

In AXS-100XT there is no

transformer.

Figure 1 - Mounting

 

 

 

Page 1 of 5

 

DE6280-9 

 

 

 