AC-2200 User Guide
48
Union Community / (138-050) 5
th
Fl., Hyundai Topics Building, 44-3, Bangi-dong, Songpa-
gu, Seoul, Korea // Tel : 82-2-6488-3000 , Fax : 82-2-6488-3099
E-mail: [email protected]; http://www.unioncomm.co.kr
3.5.3.3. Door Open Alarm Setting
Default Setting: ‘00’
This option allows the terminal to check the time when the door is open. If the door is open
over the set time (minimum 5 seconds to maximum 30 seconds), an alarm occurs.
When the
time is set to ‘00’, no alarm occurs. Even if the time is set to 01~04, an alarm starts to sound
after the lapse of at least 5 seconds.
The door must be closed within the set time. But, it may not be closed due to unforeseen
circumstances. The alarm allows users to check the cause that the door is unclosed and take
any action so that the door can be closed normally.
To use this function, the lock must have the function to monitor whether the door is open or
close. The monitoring pin of the lock must be also connected to the terminal. To check
whether the door is open or close, the mode must be set to ‘2’ or ‘3’.
After selecting the set value, press [F4] button long, and the screen will finish all the setting
of the door and move to the upper menu.
3.5.4. Volume Setting
Select [F3~] → [3.Option] → [4.Sound] on the main screen, and the following screen will appear.
3.5.4.1. Voice Volume Setting
Default Setting: ‘3’
This option is to set the volume during voice guidance. If the volume is set to ‘0’, the voice
message does not come out.
Press [ENT] button to move to the next setting.